On hands professional expertise in all aspects of Cadillac diagnostics and repair mid 1970`s thru 2000 year vehicles. GM certified in electronic fuel injection, Automatic transmission, Heating and A/C, and onboard vehicle computer diagnostics.

Experience
Held over 15 GM certifications prior to retirement in 1989.

Organizations
Prior to retirement held several ASE certifications, numerous Factory certifications.

 
   

You are here:  Experts > Shopping > Vintage Cars > Cadillac Repair > 1992 Seville

Topic: Cadillac Repair



Expert: autohelp
Date: 7/21/2008
Subject: 1992 Seville

Question
I have a 1992 Seville and the blower motor stopped working. I checked all the fuses in the trunk, under the hood, including the maxi fuses, and all seems ok. I can put 12v to the motor and it runs, what am I missing?

Answer
In most cases the fault lies with the POWER MODULE which is located just above the blower motor and about 4 inches to the left when standing in front of the car. You will see 1 or 2 electrical harnesses plugging into the TOP of the module which is held into the big plastic housing by 3 7mm screws. Remove the power module and you will see a large aluminum finned cooling component attached to the bottom of the power module. This is how to be sure you have the correct component.