Chimney & Fireplaces/Chimney repair

Advertisement


Question
QUESTION: Fireplace chimney built in 1896, stacked limestone.  What is best product to fill some holes in the chimney where the mortor has fallen out? Also would like to even our floor of fireplace...it has cracks in it...High heat cement?

ANSWER: Hi Scott,

Are you asking about filling holes in the exterior mortar of the chimney or the interior of the flue?  

If exterior, match the mortar with the type that the chimney was originally laid up with.

If interior and the chimney is lined, I recommend you contact a local CSIA Certified Chimney Sweep to do some on-site diagnosis of your problem.

You can find a CSIA Certified Chimney Sweep at www.csia.org.

If interior and the chimney is unlined, don't use it for venting anything without a lining system.  In this case, I recommend you contact a local CSIA Certified Chimney Sweep to do some on-site diagnosis of your problem.

You can find a CSIA Certified Chimney Sweep at www.csia.org.

If the floor is firebrick, and uneven, remove the firebrick, level the bed with refractory mortar, then install new firebrick with refractory mortar.

Thanks for using AllExperts.Com and good luck with your project.

Sincerely,
A. Bart Ogden, President
Home Safe Hearth & Chimney, Inc.
Wichita, KS
Voice 316-265-9828
Fax 316-265-9890
www.HomeSafeKS.com

CSIA Certified Chimney Sweep #2653
CSIA Certified Dryer Exhaust Technician #10
NFI Certified Wood Specialist
NFI Certified Gas Specialist
NFI Certified Pellet Specialist
NFI Master Hearth Professional
NCSG Technical Advisory Council Member

---------- FOLLOW-UP ----------

QUESTION: Thanks for the info above...very helpful.  The chimney is unlined and we plan to install a stainless steel liner inside.  Two questions: 1. What is best way to attach the lower end of liner to top of masonry fireplace? 2. What diameter liner?...opening of fireplace is 32H X 32W X 24D and 42H to top inside of fireplace.  Opening at top of fireplace is 4" X 27".  Height of chimney is 18'.  Thanks.

Answer
The cross-sectional area of the flue must be at least 10% of the fireplace opening.

You'll need AT LEAST 1" all the way around the liner for the insulation.

The liner must be tied into the top of the smoke chamber area with a material like Chamber-Tech 2000 and it must be tied into the top of the chimney as well.  This is NOT a recommended DIY job!

I recommend you contact a local CSIA Certified Chimney Sweep to do some on-site diagnosis of your situation and to provide a proposal for repair.

You can find a CSIA Certified Chimney Sweep at www.csia.org.

Thanks for using AllExperts.Com and good luck with your project.

Sincerely,
A. Bart Ogden, President
Home Safe Hearth & Chimney, Inc.
Wichita, KS
Voice 316-265-9828
Fax 316-265-9890
www.HomeSafeKS.com

CSIA Certified Chimney Sweep #2653
CSIA Certified Dryer Exhaust Technician #10
NFI Certified Wood Specialist
NFI Certified Gas Specialist
NFI Certified Pellet Specialist
NFI Master Hearth Professional
NCSG Technical Advisory Council Member  

Chimney & Fireplaces

All Answers


Answers by Expert:


Ask Experts

Volunteer


Bart Ogden

Expertise

I can answer questions related to chimney and fireplace cleaning, construction and repair as well as questions related to the performance of chimneys and fireplaces. I can also answer questions related to clothes dryer vent cleaning and repair. Additionally, I can field questions related to masonry repair.

Experience


Experience in the area:
28 years experience in the chimney service/installation/repair field
President, Home Safe Hearth & Chimney, Inc. Wichita, Kansas

Professional Organizations:
Member, National Chimney Sweep Guild (NCSG)
Member, Hearth, Patio & Barbecue Association (HPBA)
Member, Kansas Guild of Professional Chimney Sweeps (KGPCS)
Member, Midwest Chimney Safety Council (MCSC)
Member, Kansas Association of Real Estate Inspectors (KAREI)
Past At-Large Director of the National Chimney Sweep Guild
Past At-Large Director of the Chimney Safety Institute of America
Past Secretary, National Chimney Sweep Guild
Past Secretary, Chimney Safety Institute of America
Member, National Chimney Sweep Guild Technical Advisory Council
Member, Chimney Safety Institute of America Certification Committee
Past Chairman, CSIA Chimney Safety Education Brochures Committee
Past Chairman, NCSG Nomination Committee

Publications:
SWEEPING Magazine, The Journal of Chimney & Venting Technoloty, A Publication of the National Chimney Sweep Guild
SNEWS, The Chimney Sweep News
THE KANSAS SWEEP, The Voice of the KS Guild of Professional Chimney Sweeps

Education/Credentials:
BA, Wichita State University
C.S.I.A. Certified Chimney Sweep
C.S.I.A. Certified Dryer Exhaust Technician
N.F.I. Woodburning Specialist
N.F.I. Gas Specialist
Chimney Diagnosis & Documentation Seminar
Ahren's Masonry Restoration School Graduate
Advanced Gas Certification
Master Gas Certification
Licensed Mechanical Contractor
Pellet Appliance Specialist
Venting Design Specialist
Dale Carnegie Course Graduate

Awards and Honors:
Superior Dealer Award, Ventinox Chimney Lining Systems

©2012 About.com, a part of The New York Times Company. All rights reserved.