Question
Hi.  I got a question I get different answers on.  I want to put a majestic factory built woodburning fireplace in my living room.  I want to run the (sk8) pipe out the wall at 30 degrees and then run straight up the outside of the house.  My concern is with the firestop.  The specs state you need one for the ceilings and it clearly states that a firestop is not needed through verticle walls.  Is this something I should be concerned with?  any help is appreciated.
thanks

Answer
Eric,

You must provide a chase inclosure for your installation. I'm guessing that you have a second floor above the desired location and and that is the reason for breaching the vertical wall? You will need to provide an effective barrier, firestop at the floor ceiling line of both the first and second floor. The reason for the chase inclosure is to help insulate the chimney pipe. The amount of vertical run exposed to the cold temps outside will have a negative effect on the performance of your fireplace. You should also consult with the tech department of Majestic fireplace and the installation instructions provided if you have any questions on the installation of this product. Good luck.

Chimney & Fireplaces

All Answers


Answers by Expert:


Ask Experts

Volunteer


Randy Brooks

Expertise

Inspection of Masonry, Pre-cast Tilt-up, and Factory Built Fireplaces as well as Free Standing & Insert, Gas, and Wood Appliances. We also provide Hearth Fire Loss Investigations, Litigation Support, Consulting Services, Flue Sweeping, Installation and Repair. Additionally, I’ve been a chimney sweep for 23 years, service and install hearth appliances as well as being recognized by the Superior Court of California as an expert witness.

Experience

Brooks Chimney Sweeping Since 1989 Ojai, CA Owner / President www.brooks-hearth.com

Organizations
NCSG, MEMBER,(National Chimney Sweep Guild), Member since 1990, Board of Directors representing Region 6, (CA, NV, AZ, UT, OR, WA, ID, WY, MT, AK and HI,) 2004-2011, ethics committee chair, 2004-2005, executive committee member, Vice President, 2006-2008, President, 2008-2011. CSIA, BOD (Chimney Safety Institute of America,) Board of Directors, ethics committee chair, 2004-2005, executive committee member, Secretary, 2005-2006, Vice President, 2006-2008, President, 2008-2011. HPBA, MEMBER, (Hearth, Patio, & BBQ Association,) since 2002. NFPA Member, (National Fire Protection Association) Since 2009. Technical Committee member for the 211 Standard.

Education/Credentials
California State Licensed Contractor, C61-D34, #750710. http://www2.cslb.ca.gov C.S.I.A., (Chimney Safety Institute of America,) Certified Chimney Sweep, #2580. Held since 1990 re-certified in ‘93, ‘96, ‘99, ‘02, ‘05, '08,'11. http://www.csia.org F.I.R.E. (Fireplace Investigation, Research & Education Service,) Certified Inspector, #FP-006. Held since 2000, re-certified in ’03, ‘06. http://www.f-i-r-e-service.com Fireplace Investigation, Research & Education Service,) Advance Expert Consulting & Witness, certificate, ’05 N.F.I. (National Fireplace Institute,) Certified Gas & Wood-Burning Specialist, #133851. Held since 2002, re-certified in '05,‘08. http://nficertified.org