hairlip wrote at 2015-06-22 15:36:16
MY 40 year old Doerr motor quit starting. 1HP 115vac/Sears air compressor plugged into 15A socket. Replace top 485M capacitor and it started a couple times but not the next. Hums. I unplugged it before it can blow anything. I tapped back of motor with hammer and it starts fine even after building up pressure. So I got to inspect inside of motor rear to see how the start circuit works and what could be faulty at times.




Mr Nick Wiese wrote at 2015-12-03 01:34:40
Please note in a pinch if a 15 amp with 14 gauge wire is not enough, the utility room or clothes washer plug in the USA is still a 12 gauge wire and a 20 amp breaker. you may use a 12 gauge extension cord. for a test or short term use this will often get you by. and more air hose as well.  


Electric Motors

All Answers


Answers by Expert:


Ask Experts

Volunteer


Will

Expertise

Three phase/ AC DC single phase motors, controls, any problems or failures, motor installation, performance issues, connections. All other electric motors/gearboxes/apparatus. Specialty repair concerns, obsolete motors and solutions. Other mechanical or specialty equipment. See my profile under Home/electrical at this site

Experience

30 plus years in the electrical motor and apparatus repair industry. VP level management of repair facilities, current owner of my own specialty repair and consulting firm.

Organizations
EASA, IBEW [retired], other specialty organizations, Lubrication, Vibration EDI, Tribo-electric Councils

Publications
Currently fielding concerns at this site under "Home Electrical"

Education/Credentials
4 year technical, College level specific courses, EASA repair courses, vibration analysis electronic and electrical trade school.

©2016 About.com. All rights reserved.