You are here:

Electric Motors/Need wiring connection, 1 ph motor


I bought a GE 1 ph motor and is running the wrong rotation.  Need rotation and 115 vac connection?  Model # 5K649687Y, 1.5 HP, 1725 RPM, 115/230 Volt, 14.8/7.4 amp, has 7 leads, RED-T8, ORANGE-T3, PURPLE-P1, (TOGETHER)  WHITE-T2, BLACK-??, YELLOW-T4, (TOGETHER)  BROWN-P2, (NOT USED) Runs on 115 vac, 7.7 amps, with C.W. rotation. Can you help me? Budd

THAT SHOULD BE 115 VOLT CONNECTION,   red T3 and unmarked black should be the other start     swap red with black    that should reverse direction

Correction    red T8 not 3        but same instructions swap red with black      8 and 5 are normally start winding leads       black should be 5  

Electric Motors

All Answers

Answers by Expert:

Ask Experts




Three phase/ AC DC single phase motors, controls, any problems or failures, motor installation, performance issues, connections. All other electric motors/gearboxes/apparatus. Specialty repair concerns, obsolete motors and solutions. Other mechanical or specialty equipment. See my profile under Home/electrical at this site


30 plus years in the electrical motor and apparatus repair industry. VP level management of repair facilities, current owner of my own specialty repair and consulting firm.

EASA, IBEW [retired], other specialty organizations, Lubrication, Vibration EDI, Tribo-electric Councils

Currently fielding concerns at this site under "Home Electrical"