| Subject | Date Asked |
|
| MY lights went out when changing a light bulb. | 11/21/2009 |
Q: I have a lampficture in my kitchen that has about 8 small light bulbs. There were only 3 light bulbs ... A: It is possible that part of the old bulb is still in the socket and creating a dead short. With the ...
|
| direct wiring a european model waterheater | 11/20/2009 |
Q: i purchased an under the sink instant water heater, little did i know it was a european model unit, ... A: You will need a dedicated line from the breaker panel to that outlet under the sink. If your outlet ...
|
| Old Breakers | 11/20/2009 |
Q: I was wondering if HACR breakers were necessary years ago. While I was looking online at older ... A: HACR breakers react differently than the older standard breakers. Even fuses for HVAC equipment act ...
|
| Testing low volt transformer | 11/19/2009 |
Q: New home. Five years old. My low voltage lights don't work in my bath and I tried replacing the ... A: First you test the high voltage being supplied to the transformer. Since a transformer merely takes ...
|
| romex to knob and tube switch leg in wall | 11/18/2009 |
Q: ..I'm try to abandon knob and tube in the attic...will run 12/2 romex from new panel..should i use ... A: In my experience some of the most dangerous incidents of k and t is in the wall so I hope you are ...
|
| kitchen circuits | 11/18/2009 |
Q: i am updating my kitchen which has 15 amp circuits, do I have to upgrade existing circuits to 20 ... A: If you are pulling permits for this job you will have to follow what the AHJ dictates. So you will ...
|
| 220 V 2 pole Breaker | 11/17/2009 |
Q: I have a motor that I am running an outlet for. The motor is 230 V 14 amp and comes with a 30 amp ... A: In the U.S.A this is how we would do it: If you buy 10-2 with a ground you will connect the ground ...
|
| Ceiling fan lighting issue | 11/16/2009 |
Q: I have an issue with my ceiling fan light kit. The first kit capacitor blew and Hunter sent me a new ... A: Voltage in Japan is 100 volts, ungrounded, and either 50 hz or 60 hz depending on what area you are ...
|
| Is replacing the entire subpanel overkill? | 11/15/2009 |
Q: After inspecting our home built in 1965, an electrician recommended that we replace the subpanel in ... A: If you have a certain type of panel then I would say yes you need to update it. That panel is over ...
|
| Eletrical line problem | 11/15/2009 |
Q: We got a heater of 1500 watts and plugged in. But it went off and when we checked further we ... A: You are talking about two things, fuses and tripped circuits. Fuses blow and are not resettable and ...
|
| 220 breaker on a dryer | 11/14/2009 |
Q: i have a new dryer.everytime i use it it trips the breaker. i got a new breaker (20) and it still ... A: Electric dryers require a double-pole 30 amp breaker and at least 10 awg wire. After you make sure ...
|
| Bathroom exhaust fans | 11/13/2009 |
Q: I own a rental house with a small (5x8) bathroom with a very old exhaust fan (about 40 years old, ... A: Any electrical fixture above the shower or tub area needs to be on a gfci circuit. Doubtful your ...
|
| capacitors | 11/13/2009 |
Q: I have a capacitor gone in a motor,its a 400v 50hz 36uf with push on lugs at top for connection. Ive ... A: Caps wired in parallel are added together because you have increased the plate size. It is like ...
|
| Generator hookup | 11/11/2009 |
Q: I am installing a Generac 10kw propane standby generator. Pre-wired harness is 30 feet long. I may ... A: There are splicing blocks available but you have to wrap (insulate) them well. I would splice in the ...
|
| electrical | 11/11/2009 |
Q: my kitchen lights quit working as well as the fan and light on our hood vent, and in the living ... A: Without a voltmeter you are just guessing. And you should never touch electrical wires without ...
|
| Centering a chandelier | 11/10/2009 |
Q: The chandelier is slightly off center due to the ceiling joist. The electrical box is attached to ... A: The ceiling joists are rarely found in the center of a room so you will need to have attic access. ...
|
| Size &t ype | 11/10/2009 |
Q: I have a new detached garage 150 ft from main box. I want 220& 110 underground (no conduit)type ... A: What you need to know is how many amps you plan on using. Add up your lighting, your air compressor, ...
|
| Range Outlet | 11/9/2009 |
Q: I have a question regarding moving the outlet for my range. I am doing some rearranging of my ... A: You should test the outlet for power after you turn off the breaker and before you disconnect it, ...
|
| Four Way Switch | 11/7/2009 |
Q: I recently switched an existing four way switch to a white one and since then the whole system ... A: If it worked before you changed the switch it means you have miswired the new switch. The new ...
|
| switch for blower | 11/7/2009 |
Q: Im replacing a dimmer switch for wood stove the old switch has a blk and white wires the new has 2 ... A: They are different because they were made at different times, perhaps from a different company, both ...
|
| adding ceiling light in existing room | 11/6/2009 |
Q: Is there a technique for running the wire (romex) in a finished wall and ceiling without tearing up ... A: Pulling wires is partly technical and partly an art form. Having the right tools makes all the ...
|
| Shop Wiring | 11/6/2009 |
Q: I recently built a shop and need to get power to it. An electrician suggesting taping my main power ... A: The amount of lighting will depend on several factors. One is your age, another is what type of ...
|
| gfci switch wiring | 11/5/2009 |
Q: I plan on wiring a switch to an outdoor lantern using power from my gfci load out. I have run my ... A: Hot from the load terminal will go to the switch. Neutral from the load terminal goes to the switch ...
|
| Shop Wiring | 11/5/2009 |
Q: I recently built a shop and need to get power to it. An electrician suggesting taping my main power ... A: The attic is better than a ditch. I do not like aluminum so I always suggest copper. The size of the ...
|
| Shutting off when hot | 11/4/2009 |
Q: I live in a older home and my kitchen and bath overhead lights are on the same circuit. I also have ... A: The first things to look for are wrong wattage bulbs and wrong type of bulbs. Each light is built ...
|
| 12/3 | 11/4/2009 |
Q: Good afternoon, We just ran 3000 ft of 12/3 and have a power converter (for a lack of better words) ... A: At 3000 feet you are going to have major voltage drop issues. What type of voltage and wattage do ...
|
| Multiple outlets stopped working | 11/3/2009 |
Q: After reading thru many question and answers, I believe I know what at least what to check. Anyway I ... A: First, throw the tester with lights in your drawer and get a digital voltmeter (they are less than ...
|
| 1930's school clock | 11/3/2009 |
Q: I have a 1930's school clock. It has 3 wires. Black, White, Red. The lable says 24 VDC. Does that ... A: How the schools kept all the clocks running at the same time, which is very important when you have ...
|
| Installing Appliances | 11/2/2009 |
Q: I will be installing a dishwasher in my mobile home tomorrow and have a few questions. 1) Am I able ... A: I am not familiar with local codes for your area and you may need a permit for what you are doing. ...
|
| only getting 52 volts from 110 volts | 11/2/2009 |
Q: I have a wire going to light sconces where I am reading about 52 volts. This wire is connected in a ... A: How I would troubleshoot this is to check all the connections in the switch box (with the power off) ...
|
| Hot tub circuit | 10/31/2009 |
Q: I have a hot tub that requires a 40amp circuit. Here is how I have installed it. There is a GFI ... A: The wire at that length is rated for a 40 amp breaker. It would be 50 amps if it was under 100' in ...
|
| Short cirucit? | 10/31/2009 |
Q: House electrical to separate building (Studio). Problem: Low voltage 20-30V on the studio side. On ... A: The wires could of been nicked originally and the conduit leaks somewhere. Once the ground became ...
|
| Short cirucit? | 10/30/2009 |
Q: House electrical to separate building (Studio). Problem: Low voltage 20-30V on the studio side. On ... A: You say you have 110 volts at a double pole breaker but you should be getting 220 volts across them. ...
|
| Freaked-out Smoke Detector | 10/29/2009 |
Q: We have a ceiling fan and smoke detector in one of our bedrooms. Whenever the ceiling fan is turned ... A: I have seen lower-grade ceiling fans get so hot when they are on that you cannot touch the base and ...
|
| Capping electrical outlet (plug) | 10/29/2009 |
Q: I have several outlets I want to cap, with blank plates, what is the safest way to do this? A: With the power off, disconnect the wires from the outlet and put wire nuts on them and then wrap ...
|
| GFCI outlet | 10/28/2009 |
Q: I am also on the board, in roofing and ventilation. I am remodeling a bathroom on my home. One ... A: If this circuit goes on to feed other outlets outside of the bathroom that are not normally gfci ...
|
| 6+ wires in Ceiling Light | 10/26/2009 |
Q: I am trying to replace an existing ceiling light that for some reason has 3 black, 3 white and a few ... A: It sounds like you should wire it the same as the old one. I am not sure what you mean when you say ...
|
| SMOKE COMING FROM ELECTRCAL OUTLET | 10/25/2009 |
Q: THEN NOTICED SMOKE AT THE RECEPTACLE. WE QUICKLY TURNED OFF UNIT AND UNPLUGGED. WATCHED AND WE DID ... A: If the unit was running at the appropriate amp draw then it may be that you had a loose connection ...
|
| Open Circuit ? | 10/22/2009 |
Q: In my home some outlets and switches on a circuit work and some do not. This includes a light switch ... A: Look for gfci outlet(s) that could of tripped. If that is not it start checking each circuit at the ...
|
| fused 120 volt outlet | 10/22/2009 |
Q: Is their such a thing as a fused 120 volt switch or outlet? A: The difference between a fuse and breaker is that the fuse blows and is not resettable, whereas the ...
|
| Switch Leg Issue | 10/21/2009 |
Q: I have a new construction switch leg question. My basement has 8 blue box pull string light fixtures ... A: You really should have two separate circuits for the lights and outlets. I always recommend putting ...
|
| Fuses | 10/20/2009 |
Q: I have two rooms next to each other. Each time I turn on the heater and the TV in one of the room, ... A: Check the wattage of the heater and see if you are drawing more amps with that and the T.V. on at ...
|
| 220 line problem | 10/19/2009 |
Q: I have a problem...Each time I run my electrical dryer, I blow a circuit. At firs, I thought it was ... A: One option is to have the factory service come and look at the new dryer to establish that the dryer ...
|
| 220 line problem | 10/19/2009 |
Q: I have a problem...Each time I run my electrical dryer, I blow a circuit. At firs, I thought it was ... A: What needs to happen is an amp meter put on the circuit and watched while the dryer is running. If ...
|
| resident wiring | 10/18/2009 |
Q: I visited my mother and she had six wall outlets that when I put a volt meter on them I got a ... A: The only time a broken ground would affect your reading is if you are testing to ground. If your ...
|
| oven bake element | 10/18/2009 |
Q: I need to replace my bake element that burned out I took the old one out and thought that there was ... A: At this point you should look at the schematic. But, normally the two black wires go together while ...
|
| connecting cook top to stove | 10/17/2009 |
Q: the cook top have 4 wires black,red,white, and a ground new wall mount stove has three black,red,and ... A: Usually the red and black are the two hot legs, white is neutral, and green is ground. You could ...
|
| Oven and Microwave Electric Supply | 10/16/2009 |
Q: Doing a kitchen makeover. I just removed a built in double oven. It had a plug/socket 240V supply, ... A: If the two are one unit all you do is wire it to the existing wire and check to make sure you have ...
|
| long distance wiring | 10/16/2009 |
Q: i have a 200 amp service pole about 300 feet away from the main panel of my home. what size wire and ... A: The rule of thumb is for every 100' over 100' you go to the next bigger size for copper wire. The ...
|
| question regarding sub panel | 10/15/2009 |
Q: I am looking to update the sub panel located in my garage (main panel in house). The main panel has ... A: First you need to establish how many amps you need for your house and that will tell you the ...
|
| kitchen wiring - countertop and dishwasher/disposal | 10/14/2009 |
Q: I am doing a complete remodel of my kitchen, down to the studs. Everything is exposed, and I'm ... A: As far as I know you can install as many outlets you want on the counter, as long as a 24" cord can ...
|
| 220 dryer plug | 10/13/2009 |
Q: i had to change the plug to fit dads old dryer(dryer plug to range plug),we decided to get a new ... A: At this point you need to take a voltmeter and verify which wires are supplying the 220 volts and ...
|
| 240V double pole fuse amperage | 10/12/2009 |
Q: I have a simple question that I've had people give me different answers. I have fuse box with a ... A: Two 30 amp fuses. You have up to 30 amps flowing through the two fuses so if you have 15 amp fuses ...
|
| Replaced bathroom switch, now GFI trips | 10/12/2009 |
Q: Bathroom, separate light and fan controlled by a pair of SPST switches with a common terminal on one ... A: You need to find out if you have reversed polarity, meaning the white is hot and the black is ...
|
| new LG 240v. 18,000 ac wall unit | 10/11/2009 |
Q: installed this unit 10/09/2009, i have a new 200 amp service, used a 20 amp 2 pole breaker switch, ... A: What do you get when you measure from hot prong to hot prong? You mentioned 123 at each prong but we ...
|
| New Construction Recessed Lighting with no access | 10/11/2009 |
Q: As I understand the NEC code, all junction boxes must be accessible without removing ... A: Lets use some good old common sense for this situation. If you install new construction in an area ...
|
| short | 9/24/2009 |
Q: I have an issue with one side of my mobile home losing electricity occasionally, actually off more ... A: It sounds more like an "open" rather than "short". I strongly recommend hiring an electrician ...
|
| service panel in exterior wall | 9/22/2009 |
Q: I am putting a service panel in an exterior 2x6 wall in my new garage due to the short length of the ... A: If the vapor is a major concern I would just run my conduit up from the box, on the outside, and ...
|
| wireing diogonogistics | 9/22/2009 |
Q: how can i trace the problem in an apt bldg on 2nd floor apt whenever they turned on the shower they ... A: Take a volt measurement between the showerhead and a reference ground that you know is really ...
|
| OPEN GROUND | 9/21/2009 |
Q: When installing a new outlet, tester showed an open ground....When I tested all of the outlets in ... A: It is possible that your house is old enough to not have ground wires. That was common in older ...
|
| electric | 9/21/2009 |
Q: I am replacing a combination switch outlet with a combination switch/gfci (Shock Sentry) I have a ... A: Your terminology is a little confusing. By "two wire system" do you mean two wires in one ...
|
| Question | 9/20/2009 |
Q: Is it normal to hear a buzzing sound coming from the electrical panel when the A/C comes on? Thanks A: It depends on where the buzzing is coming from. It can be a sign of a weak or loose breaker, loose ...
|
| Ceiling fan w light | 9/18/2009 |
Q: I'm wiring a ceiling fan and light is not working. situation....hot wire comes into switch ... A: When you installed the light kit make sure the quick-connect connection is tight. Have you tried the ...
|
| Thermostat for fan control | 9/18/2009 |
Q: I'm trying to get ventilation into a root cellar to cool it with night air during our hot summers ... A: Let me see if I understand, you want the cellar fan to come on when the outside air is less than 55 ...
|
| Electrical Outlet problem | 9/17/2009 |
Q: My daughter has an older home with an electrical outlet that has a 6 plug expander box plugged into ... A: Check the rating of the expander to make sure it can handle the amps of the dishwasher. Current ...
|
| shed wiring | 9/17/2009 |
Q: I can bring power to my 10x10 shed directly from my meter box whioh has breaker switch capability. ... A: You can use romex but that is hard to pull through the conduit. Look for wire with a THHN rating ...
|
| Dead breaker? | 9/16/2009 |
Q: I will start at the beginning; last winter, we had an electrical issue with our lights dimming, then ... A: There are a couple of possibilities and all are easier to verify when the problem exists. You did ...
|
| wiring a shed | 9/15/2009 |
Q: I can bring power to my 10x10 shed directly from my meter box whioh has breaker switch capability. ... A: I like PVC conduit in the ground for protection of the wire. You can go directly from a breaker to ...
|
| Electrical Panels | 9/14/2009 |
Q: I converted by home to a square D 200 AMP Sub panel with 30 breakers. I need to know which Square D ... A: If I understand correctly you installed the 200 amp subpanel and now what to upgrade your main. If ...
|
| hot tub | 9/13/2009 |
Q: i was advised to use 6 gauge wire to 50 amp breaker box, do i need to run 6 gauge from outside ... A: Your hot tub should have a GFCI disconnect and if it is on a 50 amp breaker then yes, you would use ...
|
| Upgrading 200 Amp Residential Load Center to 400 Amp | 9/10/2009 |
Q: Just a bit over 25 years ago I was a lic. cert. electrician, HVAC, B1 contractor in LA County, CA. ... A: Yes, but at least you get to live in Florida. This upgrade to 400 amps is not going to be cheap, ...
|
| Upgrading 200 Amp Residential Load Center to 400 Amp | 9/9/2009 |
Q: Just a bit over 25 years ago I was a lic. cert. electrician, HVAC, B1 contractor in LA County, CA. ... A: You will need to get the utility company and the local AHJ involved in this. The utility company ...
|
| tapping off a 220 circuit for a new GFI Circuit | 9/9/2009 |
Q: I built a shed 150 feet from my home. I ran 14/2 underground wire ( bk, wht, gnd) in gray PVC to the ... A: You probably should of asked for advise before this project began. The 14/2 is undersized. You ...
|
| 48v at box with power off | 9/8/2009 |
Q: I was attempting to replace a builder installed fan in a master bed room. With fan removed, and ... A: This is why a person should always, always check for voltage before working on wires. Do you just ...
|
| tube and knob wiring | 9/8/2009 |
Q: isit easy to determine if electricity is stii activein a old house.we want to blow insulation in the ... A: Yes, it is easy to determine if electrical wires are live. An inspector would have you remove old ...
|
| sub panel on a detached garage | 9/6/2009 |
Q: I was reading one of your responses on allexperts.com and I was curious about a situation I'm having ... A: Two grounding rods are okay as long as they follow code when installing them. This is not the normal ...
|
| Power fluctuating up and down | 9/5/2009 |
Q: The power and my home kept cutting off so I called an electriction to fix the problem. The guy said ... A: If your 15 amp circuit has any wire smaller than 10 gauge there is now a fire hazard by installing ...
|
| double switch outlet | 9/4/2009 |
Q: i am trying to replace a double switch outlet that turns two different lights on and off. each with ... A: Let me make sure I understand. You have a switched outlet that both the upper and lower prongs are ...
|
| electrical outlet | 9/3/2009 |
Q: I changed the light bulb. The breaker never shut off and the outlet now won't work as well as ... A: Look for a gfci outlet that may have tripped. If that is not the problem you will need a voltmeter ...
|
| wire size for oven | 9/3/2009 |
Q: What size of wire do I need for a 50 foot span of wire to a 240V double wall oven Total Connected ... A: According to the math that would be a 40 amp circuit so the wire size would be #8 awg copper. But ...
|
| Wiring two fixtures to one switch | 9/2/2009 |
Q: I have two exterior fixtures that need to be controlled by one switch. I know how to do this where ... A: At the switch you should have 2 sets of 3 wires (black,white,ground) already there and now you will ...
|
| 220V outlets | 9/2/2009 |
Q: I live in a small mobile home and both the stove and the refrigerator spaces are the same size. I ... A: Are you saying you want to swap where the stove and refrig are or remove the refrig and install a ...
|
| ceiling light | 8/31/2009 |
Q: I changed a ceiling light but didn't connect the ground wire to anything. There was a bare (I ... A: You should have a bare copper wire in the ceiling box and a bare wire from the fixture. They get ...
|
| AC Fan Motor Wiring | 8/31/2009 |
Q: The fan in my air conditioner unit does is not turning on. I have confirmed that the motor is ... A: You did not say but it sounds like this is the outdoor fan motor. Normally the outdoor fan is not ...
|
| Covering over house wiring | 8/30/2009 |
Q: I'm adding storage flooring using 4X8 sheets of osb on top of the bottom of my roof trusses. Some ... A: Wiring ran across joists rather than beside are suppose to have firring ran along so people do not ...
|
| SubPanel Followup Question | 8/30/2009 |
Q: I will take your advice and install the subpanel however have a couple of followup questions. Can I ... A: I am assuming you are pulling a permit for this and it will be inspected before being energized. It ...
|
| No power in one circuit. | 8/29/2009 |
Q: I accidently threw a switch and 2 live wires in a light fixture shorted a circuit. The house was ... A: You may have blown that switch or another switch in the circuit. However, if the whole circuit is ...
|
| question | 8/26/2009 |
Q: I found out a 30A breaker is being used to power outlets and light fixtures. I have a few questions ... A: I will answer backwards. The general length were voltage drop becomes an issue is 100'. The 15 amp ...
|
| proper bonding of CSST | 8/26/2009 |
Q: There is mixed info about a proprietary method to properly bond CSST gas feed pipe. Can you clear it ... A: The manufacture, the National Fuel Gas Code, the National Mechanical Code, and the NEC, all have ...
|
| Figuring Amps | 8/25/2009 |
Q: I have a hair dryer that has 1875 watts written on it and I was trying to figure the amps. It has ... A: In your equation P/E = I P = watts E = voltage I = amps The wattage rating of 1875 is if you have ...
|
| Replacing GFI Receptacle | 8/24/2009 |
Q: I have a GFI receptacle in the bathroom of my mobile home. At the opposite end of the house there is ... A: You should not replace the GFI with a switch. Instead, hire an electrician to find out why your GFI ...
|
| Electrical circuit breakers | 8/23/2009 |
Q: I have allot of appliances on one 15 amp circuit breaker that pops or breakers if 3 out of 5 of them ... A: If the wire is 14 gauge you cannot install a 20 amp breaker on that circuit. The wires could heat up ...
|
| 6 outlets dead | 8/22/2009 |
Q: Six kitchen outlets are dead. Not sure how or what did it. I assumed it was the GFI outlet. I ... A: The 15-20 amp outlet is not an issue. So let's move on. Normally in a kitchen you have several ...
|
| Remote Lighting Circuit - Riding Arena | 8/22/2009 |
Q: I want to run 2 20amp circuits to a new riding arena we are building. One circuit is for general ... A: Your voltage drop for 400 feet is significant. With 12/2 at 400 feet you approx. have a voltage drop ...
|
| Flickering clock display on stove | 8/21/2009 |
Q: I bought a new electric glasstop range a month ago, and the digital clock and display have a subtle ... A: It sounds like how a traffic signal works. An object disrupts the field (buried under the pavement) ...
|
| Flickering clock display on stove | 8/21/2009 |
Q: I bought a new electric glasstop range a month ago, and the digital clock and display have a subtle ... A: That would be amazing if you did have some super power that allowed you to turn off electrical ...
|
| Adding a Sub-Panel on 110V Service | 8/20/2009 |
Q: Adding a Sub-Panel on 110V Service I’m in the process of remodeling a small house in Mexico and the ... A: You said 40v, but I think you meant 40 amps. I am not familiar with codes in Mexico. Here in the ...
|
| 3 way switches | 8/20/2009 |
Q: Is there any difference in the continuity of 3 way switches from the 40's? One of mine started ... A: Yes, the new 3-way switches are different than the older ones. This is what you need to do: 1. ...
|
| outdoor photo cell | 8/17/2009 |
Q: I am trying to hook up and out door photo cell for 2 lights on the front porch. Says hook blk wirt ... A: Are these two separate light fixtures working off of one photocell or one light fixture with two ...
|
| 2 Bulb Outdoor Flood Day/Night | 8/16/2009 |
Q: Checked wiring black to black and white to white. Lamps bulbs ok. Socket...center contact - how do ... A: Checking the center socket can be tricky and dangerous because the very bottom center is hot and the ...
|
| Electrical Outlets in two bathrooms and outside have stopped working. | 8/13/2009 |
Q: All the outlets in two of our bathrooms and outside have stopped working. The rest of the house is ... A: You can turn the breakers all the way off and then turn them back on. If one of them does not feel ...
|
| 110 or 220 volts | 8/11/2009 |
Q: i am preparing to replace 2 winow ac units for my mother. my father was an electrician and installed ... A: You cannot direct wire a window A/C unless you have a disconnect switch nearby. In other words, you ...
|
| Jacuzzi | 8/10/2009 |
Q: I recently installed a used jacuzzi. The new location is about 200 feet if not a little more from ... A: The rule of thumb is every 100' you need to go up one size in wire to adapt for the voltage drop. ...
|
| electrical short? | 8/10/2009 |
Q: As new homeowners my husband removed an old ceiling fan and installed the new one in our livingroom. ... A: Tripped breakers must be fully turned off before they will reset in the on position. If the breaker ...
|
| installing new electrical oven | 8/7/2009 |
Q: I have some knowledge of wiring basic things, But I'm ready to install a new elec wall oven.The ... A: The first thing you need to do is determine what the amperage rating is for the oven. If it does not ...
|
| Knob and tube wiring | 7/31/2009 |
Q: I live in a two family house. I live in the main part and the back was built on. Some of my wirers ... A: It sounds like you want the service split so both parties have a meter and pay separate bills. If ...
|
| Distance/height above roof | 7/31/2009 |
Q: I've looked all over the web trying to find what the NEC code says about electric feed wires from a ... A: This sounds more like a local problem rather than a NEC, but I cannot tell for sure without seeing ...
|
| replacing old bathroom fixture | 7/30/2009 |
Q: i recently replaced the vanity and mirror in my bathroom. Now the hole in the wall where the wires ... A: At one time, people ran the wires down to the light fixture without a box for termination and ...
|
| grounding conductor size | 7/29/2009 |
Q: I'm rewiring a home that was built in 1953. In the service panel , there is no grounding bus. I've ... A: Normally a 1/2 inch grounding rod is sufficient for a 100 amp panel. However, inspectors can ask for ...
|
| Ceiling fan has ground wire | 7/29/2009 |
Q: I'm putting in a ceiling fan and it has a light wire, a fan wire, a neutral wire and a ground wire. ... A: There should be a ground wire in the ceiling box. It may be shoved way up or sometimes they took the ...
|
| GFCI | 7/28/2009 |
Q: Will a GFCI work on an old two wire system with no ground wire? Is there a special type of GFCI for ... A: You can install a gfci on a two-wire circuit you just need to use the little sticker that comes with ...
|
| 400a service | 7/28/2009 |
Q: I'm changing out my 200a service with a 400a service in my home and need to know what size and type ... A: I recommend calling your building inspector because they are going to be the ones that inspect and ...
|
| baseboard locations | 7/27/2009 |
Q: Does an electric (240V) baseboard heater HAVE to be under a window on an external wall, or can I ... A: The main reasons for heaters being placed under windows and on external walls is that those are main ...
|
| Rewiring my outside light | 7/27/2009 |
Q: My front outside light went out and I want to replace it with a Security light. Inside my front door ... A: You may or may not be able to pull that wire because it may have been stapled to a stud. If you are ...
|
| double ovens | 7/26/2009 |
Q: what size breaker should my new double wall oven be connected to the current breaker is a double ... A: The size of the wire from your breaker to the oven will determine what size breaker can be ...
|
| AC and Dryer on same ganged ciruit breaker | 7/26/2009 |
Q: I recently had my AC go out and the AC tech came out and said my AC was fine so I called my ... A: I have a feeling you should of trusted the AC tech because they make more money by selling you a new ...
|
| Heat Pump | 7/25/2009 |
Q: My wife and I just bought our first house and we are going to need a new furnace come winter as our ... A: Congrats on your new home ownership! A heat pump is an air conditioner that has a reversing valve ...
|
| 100 amp service - adequate? | 7/24/2009 |
Q: I'm a homeowner in Philadelphia, PA, and would like to do a load calculation to determine if I can ... A: He is referring to 31,800 watts or 31.8 kilowatts. He is saying that the main panel will allow you ...
|
| power out in only 3 rooms | 7/24/2009 |
Q: my daughter plugged in and turned on the vacuum in the living room. This caused the power to go out ... A: If you do sell her who will do the vacuuming? It was not your daughter's fault so please do not sell ...
|
| RSK-2 switch for swamp cooler | 7/23/2009 |
Q: I am installing an RSK-2 speed switch for swamp cooler which calls for 2 black, 1 red, and one "hot" ... A: Use a tester to find out which wire is "hot". Leave the whites alone. With the breaker off; You ...
|
| fuse pull-outs | 7/21/2009 |
Q: I have a 100 amp square d fuse panel. I would like to hook up an electric drier. I have a spare fuse ... A: It is not just the size of the fuses you have consider; you must consider the wire size that is ...
|
| problems with 3 way switch wiring | 7/21/2009 |
Q: I changed two 3 way switches out. One upstairs, one down stairs. The down stairs switch has to be ... A: You have miswired the new three way switches. Often the new ones need to be wired differently than ...
|
| 100 amp service | 7/20/2009 |
Q: I have a small cabin (850 Square Feet) in north georgia. I have 100 amp service to the cabin and I ... A: There is a load calculation sheet that is used to determine what the service should be. Rarely ...
|
| codes | 7/18/2009 |
Q: I live in central Illinois and had a tree fall on my house tearing away the meter base and wiring ... A: I am not aware of that code. It is my understanding that if you are simply changing out or upgrading ...
|
| Switched/unswitched outlet | 7/17/2009 |
Q: Greg, Under my kitchen sink is a single receptacle with 2 outlets. They both turn on and off with a ... A: You do need to run more romex because the outlet is being fed power from the switch. The wire is ...
|
| codes | 7/17/2009 |
Q: I live in central Illinois and had a tree fall on my house tearing away the meter base and wiring ... A: You have the NEC and you have state codes and you have local codes. When you say the wiring has to ...
|
| Plugs and Switeches not working | 7/16/2009 |
Q: We recently had a new roof installed and we had them replace the turtle back electric fans and ... A: If you believe someone caused a problem why not have them back out to fix it? If the problem ...
|
| Stove Plug Wiring | 7/16/2009 |
Q: My son just purchased a new stove that came with a 3 prong plug. The previous owner took the plug ... A: If he did wire incorrectly you have a dangerous situation. It means the chassis is now energized ...
|
| dryer wiring | 7/14/2009 |
Q: I am trying to hook up a dryer in my home. The previous outlet was left hanging under the house and ... A: The old way of wiring 220 volt outlets was to use black and white as hot and bare wire as ...
|
| A/C Circuit Breaker | 7/13/2009 |
Q: We are trying to replace our A/C circuit breaker. According to the front it is a Challenger 4 pole ... A: You will most likely need to put in a 20a double pole with a tiebar. It may be that the two circuits ...
|
| Wiring a new garbage disposal | 7/12/2009 |
Q: I want to install a new garbage disposal in a 40 year home that never had one. The source of power ... A: Technically the washer should be on it's own circuit, the kitchen outlets on their own circuit, and ...
|
| Window ACs trip breaker | 7/10/2009 |
Q: I live in a double wide mobile home with three window ACs. One in the back, the front, and in the ... A: You will need to hire an electrician to examine your circuits and perhaps run one or two new ...
|
| cook top wiring | 7/10/2009 |
Q: I have a two wire coming out of the wall with ground. The cook top, which is a Jenn_Air Model ... A: The two wires coming out of the wall sound like they are supplying 220 volts which means that each ...
|
| a/c condenser fan motor | 7/10/2009 |
Q: The fan motor went out at the house,so I purchase a new one but it has 4 wires and the old one had ... A: You need to look at the schematic of the A/C and the one that is on the new motor. It is probably ...
|
| pool filter gfci breaker tripping | 7/9/2009 |
Q: I had an above ground pool installed last year and the electrical line for the filter was run about ... A: This problem is not common. All of your fittings should be water-tight as well as the outlet. You ...
|
| Ground Problem | 7/8/2009 |
Q: I live in an apartment and I recently plug a surgeprotector and the "line fault" led lit. So I ... A: There are several ways you can get this type of reading. The ground could be getting power from the ...
|
| Problems wiring a dimmer to outlet | 7/7/2009 |
Q: I am trying to create a "light control box" Essentally its a portable box that allows me to plug a ... A: Your power cord that is going into this box should have the hot wire connected to the dimmer switch. ...
|
| installing a gfci | 7/6/2009 |
Q: The electrician installed the wiring in boxes for me to complete with gfci outlets. In the first ... A: When wiring gfci outlets you only want to use the "load" terminals when you want the gfci to control ...
|
| connecting three bulb sockets | 7/6/2009 |
Q: I'm trying to make my own photography studio lighting as cheaply as possible. So far i have ... A: You will need to add up the wattage of the bulbs and then divide by your voltage (108-120) to get ...
|
| HVAC | 7/4/2009 |
Q: I HAVE A 230VOLT3 PHASE AC UNIT FROM A CONSTRUCTION JOB LOOKING TO INSTALL IT IN MY HOME. HOW DO I ... A: Yes you can but it is expensive. Unless this used A/C is worth a lot of money it would cost more ...
|
| Missing Electric Heaters in Older FL Home | 7/4/2009 |
Q: A friend just bought a 1962 house in Florida. No central heat or cooling. There are ... A: Check the ceilings. You probably have radiant ceiling heat. It was very popular for awhile. Because ...
|
| doorbell wiring | 7/2/2009 |
Q: Hey Greg, I think my doorbell is haunted. I recently purchased a home and two months after I moved ... A: Answering your questions backwards; There may be a ghost in your doorbell but you would need a ...
|
| transformer plug- in hot | 7/1/2009 |
Q: I recently had a digital cable tv receiver box hooked up; the receiver itself isn't hot but the ... A: Terms like "hot" and "warm" are subjective and really serve little or no help to me in this line of ...
|
| GFIC | 7/1/2009 |
Q: Can I install a switch in front of a GFIC so I can turn the device on and off with out unplugging ... A: Some GFCI outlets trip when power is taken away, so that is the one you would avoid if you want to ...
|
| transformer plug- in hot | 6/30/2009 |
Q: I recently had a digital cable tv receiver box hooked up; the receiver itself isn't hot but the ... A: Almost all newer electronic equipment is energized to some degree when it is plugged in. There are ...
|
| Timer switch | 6/28/2009 |
Q: My outside lights are switvhed on bmo an day-night switch. Can I install a switch that will just ... A: The simplest thing to do is install a timer inline and set the turn-on to be on early in the ...
|
| GFCI in Bathroom | 6/28/2009 |
Q: I Greg, I have a roughed bathroom with light and fan on one circuit and I have another 20 amp ... A: According to the NEC, your bath outlet(s) should be on their own circuit. If you have only one ...
|
| 2nd Electrical meter base | 6/27/2009 |
Q: I am adding a rental unit tomy existing home. I am putting in a 2nd electrical 200 amp service ... A: Cities can be different in their requirements so you will need to contact your local building ...
|
| 3 Light Series | 6/26/2009 |
Q: Greg, I just bought my first home (built in 1958) and am attempting to replace the light fixtures ... A: What you have is a 3-way circuit. It is not wired like a regular 1-switch circuit. The red wires ...
|
| Can't get new ceiling fan to work | 6/25/2009 |
Q: I have been trying to install a new ceiling fan and am having a bit of trouble. In the ceiling box ... A: The guessing game is no fun so you will need to either purchase a voltmeter or hire an electrician ...
|
| Window AC Question | 6/24/2009 |
Q: Can I safely use a 15amp 125v plug with an converter on a grounded 20amp 250v outlet? The AC is ... A: If the outlet is wired for 240 volts it means both prongs are hot and if you plug a 120 volt A/C ...
|
| grounding wire | 6/23/2009 |
Q: I live in 100 year old home and recently upgraded our box to 200 amp and our grounding wire is also ... A: If they laid the grounding rod down at the proper depth you should be able to pour over the rod. The ...
|
| Induction range - how to check amperage? | 6/23/2009 |
Q: I live in a condo that does not have any gas lines anywhere in the building, but I cook a lot so I'm ... A: If you go to your circuit breaker panel you should find several "double" breakers, meaning they are ...
|
| new ceiling fan | 6/22/2009 |
Q: I installed a ceiling fan in my master bedroom. I tapped into an existing hot wire that runs into ... A: If the circuit can handle a ceiling fan then you need a hot wire going to the switch and then from ...
|
| line of mini pendants not working | 6/22/2009 |
Q: We have a line of 3 mini pendant lights above our kitchen counter/bar. They are attached to a ... A: It sounds like when the light blew it shorted out and caused the dimmer to quit working. Turn off ...
|
| pool motor failures | 6/21/2009 |
Q: I have had 5 pool motors fail in 2 years (7/07, 1/08, 7/08,12/08, 2/08, 6/08). The 7/07 replacement ... A: If I was going to inspect this I would start by examining all of the wires to see if they are ...
|
| old electrical wiring | 6/21/2009 |
Q: i want to install a windwo a/c unit in my garage. i want to use a on/off switch in the house, run ... A: First you need to determine whether that circuit can handle the additional load of the A/C. If it ...
|
| stove top and oven breaker and wire size | 6/20/2009 |
Q: I know and electrician and asked him what size breaker to use for a stove top and oven. He said 30 ... A: 30 amp sounds too small for a stove top and oven together. You should go with the larger one. Look ...
|
| How to connect 6/2 W/G Nmb Cable | 6/20/2009 |
Q: Previous home owner pull a 6/2 W/G Nmb Cable from the main service panel to a subpanel in the ... A: It sounds like they thought about getting 220 volts after they ran the wire, which should of been ...
|
| Circuit reads 60 volts inplace of 120 volts | 6/16/2009 |
Q: 120 volt circuit with GFCI and 6 outlets reads only 60 volts at each outlet & GFCI. Disconnect ... A: Check each outlet by turning off the breaker and pulling the outlet far enough out of the box to ...
|
| Whole house surge suppressor/protection | 6/15/2009 |
Q: I'm trying to protect the new computer (and two old computers) and a new 26" HDTV from electrical ... A: If you are going to install 3-prong outlets you will need to run a ground to each outlet. Yes, I do ...
|
| 120v cicuit on 240v breaker | 6/14/2009 |
Q: would a 240v double pole, single throw breaker interupt correctly if overloaded when its wired 120v ... A: Breakers are rated in amps, not volts. What determines the voltage is whether they are single or ...
|
| 120v cicuit on 240v breaker | 6/13/2009 |
Q: would a 240v double pole, single throw breaker interupt correctly if overloaded when its wired 120v ... A: A double pole 240v breaker has a 120 volts on each pole, hence the 240 volts. Both poles are suppose ...
|
| bathroom/dining lighting doesn't work | 6/13/2009 |
Q: Our bathroom on the main floor (half bath), dining room, and porch lights are not working. We ... A: Look for a gfci outlet that may be tripped. It could be located outside or in the bathroom. Also, ...
|
| reconnecting a repaired ceil fan motor | 6/10/2009 |
Q: when connecting green with green black with black and then white with white a high pitched noise ... A: Did you remove the shipping blocks that keep the motor from turning during shipping and installing? ...
|
| 200Amp Temp. Power Pole undergound to House Sub Panel | 6/9/2009 |
Q: I have a 200 Amp temp. Power Pole that will feed a Sub Panel on an existing House approx. 100' from ... A: 1. 2/0 copper 2. I prefer conduit but either will do as long as local codes allow it. I would run ...
|
| Electric Panel | 6/9/2009 |
Q: While at a home inspection for a client the breaker box was hot to touch on one breaker and it ... A: Was the hot breaker for the A/C? If so, an A/C works hardest in the afternoon and if the sun hits ...
|
| Non-grounded subpanels | 6/8/2009 |
Q: I'm upgrading a '60s house that has a 200a old main panel, feeding two 100 amp subpanels--the house ... A: Regardless of the stove you want your subpanels grounded. With a 100 amp panel you can run #6 for a ...
|
| voltage surge? | 6/8/2009 |
Q: 3 years ago we have our apartment rewired and all lights have been changed to energy saving bulbs or ... A: I am not familiar with the codes and voltages with your country. I suspect that voltage spikes and ...
|
| Electric meter | 6/6/2009 |
Q: How can I find someone besides our electric provider to check the calibration of our meter. Our ... A: We can all expect higher bills due to our new administration. But with politics aside, there are ...
|
| Outside Floodlights mounted on wall of house not working | 6/5/2009 |
Q: I have twin floodlights mounted on either side of my house on the wall in the backyard. The switch ... A: The switches should of had two wires to each and the two wires at each switch can be reversed. It ...
|
| electrical outlet | 6/4/2009 |
Q: I have an outlet located beneath my sink for the disposal and dishwasher. The outlet burnt out, so I ... A: The white should go on the side with the biggest prong. The other side has a tab that needs to be ...
|
| old wiring problems | 6/3/2009 |
Q: Jimmy, I am installing a light fixture into a ceiling with no pre-existing fixture at that ... A: The cable with power would be the one coming in and splits and goes to each switch. And that same ...
|
| nothing 240 works in the whole house.all outlets read 120 each side. | 6/3/2009 |
Q: I have 240 volts @ each element of the waterheater on new elements but no hot water. same with the ... A: The subject says you have 120 volts on each side but then your question says you have 240 volts ...
|
| 2 in 1 light switch/power socket | 6/2/2009 |
Q: Could you help me connect a light switch and power socket (a 2 in 1 device)to my residential power ... A: For an outlet to work you need a hot wire and a neutral. Some switch boxes only have a hot coming in ...
|
| Breaker 40 Amp Air Conditioner 15 Amps | 5/31/2009 |
Q: Can I put a 15 amps air conditioner on a breaker that is 40 amps. I know I have to change the ... A: Can you? It is physically possible. Should you? That is another question. If your A/C is rated for a ...
|
| does wiring a motor to 22 increase it's performance | 5/29/2009 |
Q: Greg, I bought a Rigid Table saw that has the capability of being wired for 220v. I have been ... A: The main advantage is that the amps are reduced and you can run a smaller wire size to it and hence ...
|
| 30A | 5/27/2009 |
Q: I have a 30A double breaker feeding my detached garage. I would like to replace the fuse box with a ... A: You did not mention where the fuse box is but it sounds like the 30 amp breaker is feeding a fuse ...
|
| Electric motor | 5/27/2009 |
Q: My fan on my AC unit starts up but runs slow. The paperwork with the unit says it should pull 1 ... A: The first thing to check is the voltage. You should have between 208 and 240 volts being supplied to ...
|
| changing dihwasher from hardwire to pluggin | 5/26/2009 |
Q: is there a anything wrong with me changing my dishwasher from hardwire to cord wire plugin im using ... A: Technically, yes with each connection you run a greater risk of a loose connection. However, your ...
|
| Tankless water heater | 5/25/2009 |
Q: Most of the specifications for tankless water heaters indicate 240v and up to 100w for proper ... A: Do you mean 100 amps? 100w = 100 watts and that does not sound right. If your home is electric, ...
|
| 240v outlet | 5/25/2009 |
Q: How do I determine if my air compressor will require a 3 or 4 wire 240v circuit? can power tools ... A: Good question. The requirements should be on a metal tag attached to the compressor. If it calls for ...
|
| new light and outlet | 5/24/2009 |
Q: I would like to add a light and an outlet to a circuit. I would like to run the wire from the ... A: Lets go backwards in your questions. You are not suppose to have two different size wires in the ...
|
| installing double oven | 5/24/2009 |
Q: We are installing a ge monogram double wall oven, ZET2SMSS the specs of the metal plaque are as ... A: When the engineers build ovens they face the dilemma that each house may have a different voltage ...
|
| Air Conditioning | 5/22/2009 |
Q: We got Central Air installed the beginning of last summer. It's a BRYANT. We turned it on a few days ... A: The most typical causes of what you explained are low air flow due to one or more of the following; ...
|
| exhaust fan | 5/20/2009 |
Q: I added an exhaust fan to my washroom and connected the wiring to the existing light switch. The ... A: Frank, The white from the fan needs to be connected to a neutral wire, not to the switch. What you ...
|
| second panel for shop | 5/20/2009 |
Q: I have a 200 amp service to my house panel. I am putting a 100 amp panel in a backyard shop, 160 ... A: I am curious why you are coming off the meter box instead of main panel, but it does not matter for ...
|
| 220v socket to 110v | 5/19/2009 |
Q: Let me start by telling what happened first. I had an older a/c that uses a 220v socket which was ... A: As you are aware, you hooked 220 volts to your 110 volt A/C. I am surprised it lasted for 2 days. ...
|
| Flood light fixture switch | 5/18/2009 |
Q: Are you aware of any off/on switch that will screw into one of the three threaded holes that exist ... A: The main thing to overcome are the 1/2" threads and the switch needs to be waterproof if this is ...
|
| bathroom outlets | 5/17/2009 |
Q: We recently moved into a relatively new house (built 2006). It has 5 1/2 bathrooms on 4 levels. ... A: What do all three have in common? They should all be on GFCI breakers and all require a good ground, ...
|
| 4 electrical things quit working | 5/17/2009 |
Q: The other day, when I turned on an upstairs bathroom light switch the 5 light fixture over sink made ... A: Is it a "fuse box" or "breaker panel"? A tripped breaker can appear to be okay sometimes and the to ...
|
| Should I upgrade from 100 to 200 Amp | 5/16/2009 |
Q: I am in the process of renovating a house that my wife and I just bought. It was last renovated in ... A: Given that you are switching two big users of electricity to gas and hopefully installing a more ...
|
| Sub panel and gounding rods | 5/15/2009 |
Q: I'm getting ready to run a new sub panel and underground line to my detached garage. I'm going to ... A: This is an accepted method but check with the local building codes just to make sure before you run ...
|
| wiring from home to camper / 30amp | 5/12/2009 |
Q: I just purchased a travel trailer and I need to run a 30amp 70ft. I was just wondering what gauge ... A: I love it when you guys say "I have limited funds for this.." What is that suppose to mean to me? ...
|
| electric to a camper | 5/12/2009 |
Q: i recently bought a camper and put it 500ft from my mothers house in attempt to save for a house. ... A: The money it is going to cost you to run sufficient wire will be significant. I do not know what ...
|
| Private water pump occassionaly trips circuit | 5/11/2009 |
Q: I have been having a problem lately with our water well. It started when our pressure switch of 15 ... A: Clint, It is most likely a problem with the motor or the motor controller, or both. You should have ...
|
| outdoor wiring to backyard and building | 5/11/2009 |
Q: ...I have run romex wire to two locations in my back yard in 1/2" elect conduit, one two plug outlet ... A: Alan, There are a couple of things I believe are wrong with this picture and I probably need some ...
|
| Stanley Vemco Garage Door Capacitor Removed.. Is this dangerous? | 5/10/2009 |
Q: I have a Stanley Vemco garage door opener that began to stop going up and down intermittently ~ it ... A: You may end up burning your motor so I would recommend you replace the capacitor. I believe it is a ...
|
| Loosing Power | 5/8/2009 |
Q: I have a bedroom that is intermittently losing power. I have identified the breaker that controls ... A: Most likely they are tied together either in a junction box or an outlet box. They may also be tied ...
|
| 12/3 split (2/20 breakers) | 5/7/2009 |
Q: I have an outdoor cooking center and am leveraging a 12/3 line that was no longer used and blanked ... A: You should never put a refrigerator on a gfci protected outlet. You can have a dedicated outlet ...
|
| Electrical hum | 5/7/2009 |
Q: I have a visual horizontal line running through my tv when plugged into down stairs outlets. If I ... A: It does not have to be on the same circuit breaker to cause noise. Your neighbor a few doors down ...
|
| AFI breakers and GFI outlets | 5/6/2009 |
Q: I have a AFI protected circuit and every time i put GFI on this circuit the GFI trips am i doing ... A: It sounds like your GFI outlet is not wired correctly or you have reverse polarity. Some of the new ...
|
| Electrical hum | 5/5/2009 |
Q: I have a visual horizontal line running through my tv when plugged into down stairs outlets. If I ... A: Find out what happens after in 7pm in your house and the house connected to you. It may that your ...
|
| Running extension from light fixture to create outlet in adjacent closet | 5/5/2009 |
Q: Is it OK to just plug two prong extension cord to the light socket outlet adapter ... A: Looking at that picture I am not sure that light is up to code in that cupboard. Extension cords ...
|
| old wiring spark and dead receptacle...related? | 5/4/2009 |
Q: while installing a ceiling fan with a light, there was a spark, when pulling wires through 1st ... A: The first thing is why are you working on this with the circuit breaker on? Turn it OFF before you ...
|
| Wires to light both hot | 5/4/2009 |
Q: I am doing some electrical work in a home I purchased that was originally built in the early 1900's. ... A: I need to know where you touched the probes to get this reading, and I recommend getting a digital ...
|
| wiring basic porcelain incandescent fixtures | 5/3/2009 |
Q: I am putting simple porcelain fixtures for standard incandescent bulbs (obviously compact ... A: Check to make sure the black coming in to the fixture with the switch is hot, and not the white. It ...
|
| electrical service for aeration | 5/2/2009 |
Q: Greg, I want to run an underground service line from my home approx. 600ft to my pond.All this line ... A: The first thing you need to know is the amp draw because that will determine the initial wire size. ...
|
| Light switches | 5/2/2009 |
Q: I have 3 light switches controling one light.Two of the switches work fine,the third,works only if ... A: Most likely it is wired wrong or you have the wrong type of switches. If it is wired correctly and ...
|
| 60 amp breaker | 5/1/2009 |
Q: i have to add a 60amp breaker for my pool heat pump. and there is no openings in the 200amp box, ... A: Piggy back is dangerous and against code. What you need is a subpanel and then feed from that back ...
|
| GFCI outlets | 4/30/2009 |
Q: I have a circuit in my house with 2 GFCI outlets on it. Is there any reason to have 2 on the same ... A: It is true that if the line ends with a GFCI that last outlet will be protected by that GFCI. The ...
|
| ceiling lights wiring | 4/22/2009 |
Q: I bought 4 light ceiling kit. There is no wiring scheme how to connect the rest of ceiling lights. I ... A: It sounds like you are wiring it correct, the blacks go together and the whites go together and the ...
|
| European wiring to U.S. codes | 4/22/2009 |
Q: I have a chandelier that I bought when stationed overseas in Germany. I thought I wired it ... A: Normally in Germany you are right with the color code. Two things; 1. Make sure that the lamp is ...
|
| Copeland Scroll Compressor | 4/21/2009 |
Q: I have a 54,000 btu Copeland Scroll compressor, R47K3-PFV-235, in my heat pump which draws 12 amps ... A: Your compressor draws 12 amps, but what about the fan motors? Is that 12 amps including those ...
|
| Plug powered by light switch | 4/21/2009 |
Q: I recently replaced a plug that was controlled by a light switch in my spare bedroom. I was told to ... A: If the switch originally controlled both halves of the outlet then you would not break or remove the ...
|
| Frigidaire Pro Series Stove - glass cooktop - burner quit working | 4/20/2009 |
Q: We have the Frigidaire Pro Series Model PLEF398CCA Stainless steel with black glass flat surface ... A: The element is about $150.00 and I am not aware of any programming that is needed, but a quick call ...
|
| microwave hood range | 4/19/2009 |
Q: simple question i guess may sound stupid but where do you put the plug outlet for a microwave hood ... A: The plug is usually fed up on the right side and above so you can unplug it. The plug has to be ...
|
| Wiring a pool system | 4/17/2009 |
Q: Is there a safety risk if I use the kitchen range wiring (8 Gage) from my main service panel to ... A: What you are talking about is not safe and is not to code. The only way you could follow code and ...
|
| ground rod installation | 4/16/2009 |
Q: I am about to upgrade from a 75amp panel to a 200amp panel and need to install a 10' ground rod as ... A: The inspectors in the area I live want the ground rod to stick up above the cement enough so they ...
|
| AFCI breakers tripping when it rains | 4/16/2009 |
Q: About a month ago, the two AFCI circuit breakers (15 amps each) for my bedrooms in my electrical ... A: AFCI breakers can become weaker (more sensitive) over time, just like regular breakers. And the more ...
|
| 30 amp thermostat for radiant heater. | 4/15/2009 |
Q: I was hoping to find out about replacing a thermostat. Right now i have radiant heating in the ... A: Turn off the breaker and look inside your t-stat for info on what the amperage rating is. It sounds ...
|
| dryer not heating after re-wire | 4/15/2009 |
Q: We installed a new electrical panel and changed everything to match what was there. everything ... A: The electric dryer requires 120 volts for the motor to run, but requires 220 volts for the elements ...
|
| Electric Baseboard Heat Issue | 4/14/2009 |
Q: I recently had an issue with my living room heating where the heat would constantly stay on, ... A: We normally say 220 volts or 240 volts but it is what ever the power company actually gives you. And ...
|
| wire type | 4/14/2009 |
Q: I just wanted to double check that the wiring in my home is copper wiring. My house was built in the ... A: The best way to find out what type of wire you have throughout the house is to remove the breaker ...
|
| Electric Baseboard Heat Issue | 4/13/2009 |
Q: I recently had an issue with my living room heating where the heat would constantly stay on, ... A: The first place I would start is the circuit breakers and make sure you do not have one that is ...
|
| Wiring a timer switch | 4/13/2009 |
Q: I bought a Intermatic FD60MWC Auto Shut-Off Timer ( http://www.rewci.com/infd60inspwo.html ). This ... A: Jason, I clicked on that link and read, quote "These timers are designed to replace any standard ...
|
| Circuit with hot to ground reverse | 4/12/2009 |
Q: I have a circuit that has worked fine for 4 years. Recently it quit working. The circuit is in a ... A: It sounds like a loose connection or partially tripped breaker. Start at the breaker panel and make ...
|
| Generator Transfer | 4/12/2009 |
Q: I have several questions about installing my own manual transfer switch. I have a 3kw Honda with ... A: It sounds like you are installing a subpanel type of TS, and if so then you need a double-pole ...
|
| Generator Transfer | 4/11/2009 |
Q: I have several questions about installing my own manual transfer switch. I have a 3kw Honda with ... A: Kent, Great question. With the current threats to our power grids and the horrible storms across ...
|
| power gone | 4/9/2009 |
Q: In the kitchen, I have the main overhead lights on a dual dimmer. One on one side of the kitchen ... A: What you have are two 3-way switches feeding the kitchen lights. If you do not have power at one ...
|
| 250 receptacle | 4/8/2009 |
Q: i bought a welding machine, it requires 250 volts(or 225) to use in my garage, can i re-wire a ... A: To the best of my knowledge you have the same type of voltage and frequency as here in the U.S. ...
|
| Wiring standalone garage | 4/6/2009 |
Q: I want to run power from the panel in my house to a panel in a stand alone garage I am building. I ... A: Your 10 awg is what we call 10 gauge and it carries 30 amps if the distance is less than 100 feet. ...
|
| Ground Fault Breaker | 4/6/2009 |
Q: I have a double pole 50 amp Sq. D GFCI breaker that services my hot tub. It now trips off right ... A: I found one hot tub that had a light right above the control board and it was slowly dripping water ...
|
| connecting a portable generator to a house | 4/5/2009 |
Q: I have a 5000w portable generator. I would like to use it during outages. I understand the need for ... A: Your transfer switch should come with a wiring diagram. Basically you are feeding your whole main ...
|
| 100amp to 200amp service upgrade | 4/3/2009 |
Q: I recently purchased an older farm home said to be about 100 yrs old. This house is currently ... A: If the "post and line" is the old "knob and tube" (which I suspect it is) then my suggestion would ...
|
| home power keeps tripping more and more regular | 4/2/2009 |
Q: I live in India so I’m not surprised that I have finally got an electricity issue, however it sounds ... A: Every time the breaker trips it loses tolerance so it will trip easier the next time. If you have a ...
|
| Adding Ground Wire | 4/1/2009 |
Q: I am going to be moving into an 82 year old house. The house has an upgraded circuit breaker box ... A: It would probably be better to drive a ground rod near the panel and ground the main panel. Then ...
|
| can lights | 4/1/2009 |
Q: The situation is there are 3 rooms, in feet 13 x 7 10 x 12 8 x 10 Installing 6-inch can (or ... A: Randy, Can lights can be very useful and attractive if used correctly. Here is the problem with ...
|
| outlet plugs | 3/31/2009 |
Q: I just moved into a house--in 1 bedroom a ceiling fan has been added. The light is control by the ... A: That switch use to control one of the outlets and someone made it control the fan. Does the switch ...
|
| Oven Element | 3/31/2009 |
Q: I have an old GE wall oven (guessing 1960-70 model) and one of the elements went out. I ordered an ... A: I cannot find that model number. I do not believe you can get the exact element anymore. The white ...
|
| wiring ceiling fan between 2 switches | 3/29/2009 |
Q: I am installing a ceiling fan, with remote, in family room. House is fairly new and has box set up ... A: Either someone miswired the switches or they are not meant to work together as a 3-way. Are you ...
|
| Lights and Outlets | 3/28/2009 |
Q: Recently the light in my bathroom went out, I figured it was a burnt out bulb so replaced, no light, ... A: First check for a gfci outlet. It has a little reset and test button on it. It could be in the ...
|
| Electrical Plug for Water Well | 3/28/2009 |
Q: I currently have a new home under construction. I have a brand new water well/pump ready to go but ... A: You could use a 220 volt 20 amp plug and outlet. Yes you can use the 250 volt outlet. You will wire ...
|
| troubleshooting outdoor light fixture | 3/27/2009 |
Q: Maybe you will be able to give me some more advice. My husband just replaced the outdoor light by ... A: Did you buy the exact same light to replace the one that was not working correctly? It is possible ...
|
| ground fault breaker/plug | 3/27/2009 |
Q: We live along the coast-Hurricane Ike put 8' of water in our downstairs--covering all the electrical ... A: All the boxes and junction boxes need to be checked. Water can leave a mineral trail that electrons ...
|
| Removal of electrical outlet and light switch | 3/26/2009 |
Q: I need to remove a two-plug electrical outlet and single switch light in order to accomodate new ... A: At the outlet your black wires will get connected together (wire nut), the white wires together, and ...
|
| wiring for 9kw sauna heater | 3/24/2009 |
Q: I have installed a 9kw sauna heater. The house was set up with 10-3 wire to a 30 amp breaker. When ... A: If it takes 220 volts, the heater draws about 40 amps so you need to go up to 50 amps. This will ...
|
| Outdoor number sign not working | 3/23/2009 |
Q: Need to know how to what setting my multimeter should be on and where to probe and what readings ... A: If it is A/C voltage you should set it to 700 volts A/C and touch where the two prongs of the bulb ...
|
| comes and goes | 3/23/2009 |
Q: We have a 200 amp electrical system. The electricity in one area of our basement and part of our ... A: It is possible that you are losing one leg of your power and the oven is back-feeding. The question ...
|
| Split Dual Breaker | 3/21/2009 |
Q: Electrician installed a dual 30amp breaker just in case we use an electric drier but instead we ... A: Your electrician should of ran 10/3 instead of 10/2. This mistake will only allow you to run one ...
|
| Dimming, brightening lights | 3/21/2009 |
Q: My lights and TV and fan dim then brighten, dim and brighten. It is often and is bad, but ... A: Has the landlord seen the lights flickering? Did the electric company see it? Did the electrician ...
|
| HQI aquarium lighting troubles........... | 3/20/2009 |
Q: For about the past year I have noticed drastic change sin the brightness, color temp, and longevity ... A: Did you check voltage with no load or loaded? First check it unloaded. Where did you check the ...
|
| Electric dryer wiring | 3/19/2009 |
Q: I have a used dryer that i just purchased.The plug on the dryer is a 30Amp 125v/250v 4 prong plug.In ... A: Two choices: 1. Install a 3-prong 30 amp dryer outlet and replace the 4-prong cord with a 3-prong ...
|
| broken connection | 3/19/2009 |
Q: I am having a problem in a mobile home with the wiring. I plugged in a lamp, turned it on and it ... A: Look for a GFCI outlet, usually the bathroom, kitchen, or outside, and see if it tripped. Hit the ...
|
| lights flickering | 3/18/2009 |
Q: Several of my lights at home started to flicker very frequently and I have a couple UPS started to ... A: It is possible that your circuit is overloaded, and it is possible that another circuit is causing ...
|
| 240v tablesaw swapout from 120/240v dryer | 3/18/2009 |
Q: Hughes, Just purchased a 1988 home in Houston,,,Has an existing 120/240v 30A clothes dryer on the ... A: You are on the right track. The 10/2 is actually better than the 12/2 in this case. The 6-15 is for ...
|
| Lights Come On With Dryer. | 3/17/2009 |
Q: So today perfectly normal average day sitting in the living room with my son when the power goes ... A: This sounds like a main breaker issue with one leg bad and your dryer back-fed the other leg. If ...
|
| Installing motion sensor light | 3/16/2009 |
Q: Iam tring to install a motion sensor light. I have already installed a double switch so that one ... A: You need a hot wire and neutral. A hot goes to the switch and then from the switch to the ...
|
| arc fault interrupter tripping | 3/15/2009 |
Q: my wife was vacuuming a few rooms with a kenmore upright when it shuts off. apparently, some kind ... A: Jay, The AFCI has not been perfected, but many would argue that it is better than nothing. Unlike ...
|
| electric range install | 3/14/2009 |
Q: I just removed a 35 year old electric range that was hard wired. Coming from the wall is a Black ... A: In a 2 wire plus ground configuration for 220 volts the black is hot, the white is hot, and the ...
|
| converting 4 prong dryer to 3 prong | 3/13/2009 |
Q: we converted the dryer to a 3 prong. dryer runs but no heat is producing. is there such thing that ... A: It is possible that you have energized the chassis of the dryer and extreme caution should be taken. ...
|
| Pullout disconnect | 3/11/2009 |
Q: I have a outside condensor unit AC that is rated at 15 amps. I have a 2-pole breaker feeding this ... A: You have three choices. One, you can install a disconnect that has an arm on the outside. Two, you ...
|
| Tankless Hot Water Heater amperage | 3/6/2009 |
Q: I have a couple of questions I guess. I want to install a tankless hot water heater in my house to ... A: I have a couple of answers I guess. First, which one is best depends on how many people occupy the ...
|
| Replacing a light with a loop | 3/6/2009 |
Q: I recently bought a new light to put in my daughters room. When I removed the standard light, there ... A: The old light should of had two wires coming from it (hot and neutral) to the wires in the box. When ...
|
| dryer and stove receptacles | 3/5/2009 |
Q: what is the difference between a dryer and stove outlet? We have 4 prong outlets for both, but the ... A: The reason they are different is one is rated for 30 amps and the other for 50 amps. They are ...
|
| Electric Baseboard Heaters Relay | 3/3/2009 |
Q: I have 3 baseboards all on 1 circuit breaker (kitchen, liv room & hall)that continue to run full ... A: Are these baseboard electric or baseboard hydronic heat? Since each heater is in a different room, ...
|
| Breaker Box | 2/26/2009 |
Q: I just finished instaling a new thermastat. I cutoff all the power when I'm doing any electrical ... A: Pull the dryer plug out of the outlet and try turning the breakers all the way off and then turn ...
|
| dryer outlet/welding outlet | 2/25/2009 |
Q: Ive read a lot of posts where people are using their dryer outlet for their welder. I would like to ... A: If this is brand new, the manual should tell you the required breaker size. Look at the requirement ...
|
| dryer outlet/welding outlet | 2/25/2009 |
Q: Ive read a lot of posts where people are using their dryer outlet for their welder. I would like to ... A: I like the idea of changing your dryer to 4-prong because this will separate the ground and neutral ...
|
| dryer outlet/welding outlet | 2/24/2009 |
Q: Ive read a lot of posts where people are using their dryer outlet for their welder. I would like to ... A: In a garage the NEC allows for one 220 volt circuit used for multiple devices with the understanding ...
|
| size wire | 2/24/2009 |
Q: running a new line from an old meter to a new barn; I would like to know what size wire to use and ... A: The first thing you need to establish is how many amps are you going to want/need out at the barn ...
|
| Outdoor GFCI & lamp post light | 2/23/2009 |
Q: My outdoor lamp post light recently stopped working. I replaced the photo eye sensor & actual light ... A: Think of a gfci outlet as a breaker. So all the power on the way to the outlet can be on but ...
|
| breaker keeps tripping | 2/22/2009 |
Q: About to install a can light in laundry room and discovered 4 separate 12/2 lines going to old ... A: Your homecenter store most likely sells wire markers that electricians use to put on wires so they ...
|
| dryer wire hook up | 2/21/2009 |
Q: we have a dryer and the wires are red black and white, our plug in wires are yellow blue and white. ... A: You should use a voltmeter to verify which wires are hot and which is neutral. On your dryer; red ...
|
| 3/phase air compressor | 2/21/2009 |
Q: How to tell the difference between 3/phase and 220v? There is a 3 prong twist plug on the ... A: 3 phase is how many phases you have and 220v is the measure of voltage. This question is like can ...
|
| shower fan install location | 2/20/2009 |
Q: I'm planning a bathroom in the basement and my location doesn't lend itself to placing my exhaust ... A: There isn't room in the joists to place the fan outside of the shower and run the duct through the ...
|
| cooktop wiring | 2/19/2009 |
Q: i am installing a cooktop (240). it is a 30 amp circuit (10 guage wire) i have 10/2 with ground to ... A: The installation manual should be clear on this, but if it is not then you can figure if the cooktop ...
|
| Sub Panel Installation | 2/19/2009 |
Q: Greg, I recently had a sub panel put in by my electrician. I am adding a circuit, and happened to be ... A: The neutral and ground are on the same bar at the main service panel. In other words, they are ...
|
| Sub Panel? | 2/18/2009 |
Q: I will be finishing a 1158 sq. ft. basement (home theater, rec room, home office) in a 7 year old ... A: You could run everything from the main. However, you need to weigh the cost and trouble of running ...
|
| subpanel wiring | 2/18/2009 |
Q: im rewiring my home and i have a utility room where my washer/dryer, elec water heater, and few ... A: If your dryer, water heater, and washer all ran at the same time it would probably be too much for ...
|
| wire type and capacity for downline service | 2/16/2009 |
Q: I want to know the correct wire type and size for an 80 foot run from a current load center to a new ... A: If you are only running 120v you could use copper #4, 2 wire with ground. If you are not using ...
|
| Dryer stopped working | 2/16/2009 |
Q: I had a leak in my laundry room last week from the washer drain. I went in there barefoot while the ... A: This is a perfect example of why the NEC was changed so the chassis has its own ground separate from ...
|
| Heat pump pulling tomuch amperage | 2/14/2009 |
Q: We had a Kenmore heat pump installed recently and received a whopper of an electric bill. Had an ... A: It sounds like your electric back up heat is turning on. There could be several causes but let me ...
|
| waterheater | 2/13/2009 |
Q: I would like to make my water heater quicker to recover. Why can't I wire another 30 amp circuit to ... A: You would have to check with the manufacture of the heater to see if it is designed to handle that, ...
|
| Running a Treadmill in Europe | 2/13/2009 |
Q: I have a Nordic Track treadmill that runs on 110 (I think it is uses 1100 Watts). Can I use it in ... A: A step-down transformer takes the incoming voltage and lowers it. Sometimes it is cheaper/easier ...
|
| Install Split Aircon | 2/12/2009 |
Q: I am installing a 24k BTU A/C with #10-3 w/Grd and 25 amp C/B. I intend to install a disconnect ... A: Let me explain how a split system is wired. The indoor unit (air handler) has a either a 220volt or ...
|
| knob and tube | 2/12/2009 |
Q: I am currently planning on replacing all the knt in my two story cape cod bungalow. I am adequatly ... A: It depends on how your power is ran to your house. And it also depends on local codes. For ...
|
| knob and tube | 2/11/2009 |
Q: I am currently planning on replacing all the knt in my two story cape cod bungalow. I am adequatly ... A: Whatever the service panel is rated for you will need to run wire (including the ground) that is ...
|
| wellpump pressure switch | 2/10/2009 |
Q: Pressure switch has 2 different wires coming to switch ,each separate wire has a black wire ,a ... A: If this is a 220 volt pump the switch should be double pole. If it is then there should be two sides ...
|
| 15 Amp AFI Trips | 2/9/2009 |
Q: Two questions: I think I've got too many appliances and outlets running to my 15 Amp AFI breaker. ... A: It is possible that you have the circuit loaded to the point that it is ready to trip. Each time a ...
|
| dehumidistat wall switch | 2/9/2009 |
Q: I have an existing bath fan controlled by a wall switch (line voltage) that I would like to replace ... A: It sounds like you want the fan to come on when steam builds up in the bathroom and then turn itself ...
|
| electric outlet near gas line | 2/8/2009 |
Q: Is there a code problem with installing electrical box ON the wall near the incoming line for a gas ... A: Most gas stoves require an outlet for 110 volts. It is never recommended to use an extension cord so ...
|
| Direct Box Old Electric Dryer | 2/8/2009 |
Q: Is this acceptable? There is an old dryer in the home that I am renting and it is directly hooked ... A: In all my years I have never seen a dryer direct wired to a box. All appliances that are ...
|
| thermostat replacement | 2/7/2009 |
Q: I have a seven wire thermostat that is connected to Nordyne air conditioner/heat pump. The manual ... A: It looks like you may be able use it. But with a heatpump it can get pretty complicated and it ...
|
| ELectrical problem | 2/6/2009 |
Q: I replaced a single electrical switch to a bedroom that was only controlling the light in that room. ... A: It sounds like the power to the other two room are fed from this box. You should have three sets ...
|
| knob and tube | 2/6/2009 |
Q: I am currently planning on replacing all the knt in my two story cape cod bungalow. I am adequatly ... A: Finding the neutral for a hot in the panel is very easy. I am not sure exactly what you are doing ...
|
| electric in bathroom | 2/5/2009 |
Q: recentley we added high hats in the kitchen, which is directly under one of our bathroom tub/shower. ... A: If there is a stream of water hitting electricity the current can easily flow through that stream ...
|
| GFCI wiring | 2/3/2009 |
Q: I am trying to change an outlet in my bathroom and update it to a GFCI outlet. The box with the ... A: You did not mention the ground wire. Some GFCI outlets require a ground wire connected to a good ...
|
| Lights get brighter | 2/3/2009 |
Q: In my 30 year old house, I recently replaced 2 overhead lights, (2) 2-way & (2) single pole switches ... A: It sounds like it may be time for a service upgrade and redistributing some loads. We have much ...
|
| dimmer light fan | 2/2/2009 |
Q: I am trying to connect a dimmer fan/light combo to my current fan with light. I have some prior ... A: This should be pretty easy. It sounds like the wires at the bottom go to your outlets, one of the ...
|
| new switch | 2/1/2009 |
Q: I just put in a new island in my kitchen and have 2 outlets and a switch for the garbage disposal ... A: It sounds like you either wired the switch wrong or the outlet. The switch is a 4-way switch? If ...
|
| OUTLET PROBLEM | 1/31/2009 |
Q: I had a microwave plugged into an outlet for a while. This outlet is being supplied by an outlet ... A: This outlet may be on a gfci breaker or being fed from a gfci outlet. That is the first place to ...
|
| Wiring a fluorescent fixture as a plug-in lamp | 1/31/2009 |
Q: The fixture has a ground wire but the zip wire (with 2 prong plug) doesn't. My outlet is 2-prong, ... A: I cannot tell you to disregard the ground wire that came with the fixture. If it comes with one then ...
|
| Fluorescent Lights in Garage - Take Two | 1/30/2009 |
Q: I was informed the lights are to be wired in parallel. I hope this is not a dumb question. The ... A: Parallel simply means that each light is being fed from the source. Normally the power gets ran to ...
|
| main breaker | 1/29/2009 |
Q: my main breaker keeps blowing. the watertank has its own circit but it sems like if i run any ... A: Probably the best thing to do is have an electrician take a look at your system and see what the ...
|
| wiring a oven range | 1/27/2009 |
Q: we have just pull out our old cook top and wall oven and bought a new oven range slide in. and our ... A: Your house was built during the time the NEC allowed for 3-wire connections (two hots and a ...
|
| installing outdoor outlet | 1/27/2009 |
Q: First want to thank you for your time helping others here. My question, i'll be installing an ... A: If this was new construction or remodeling the outdoor outlet would not be on the same circuit as ...
|
| Space Heater | 1/26/2009 |
Q: I am replaceing a baseboard electric heater with a built in thermostat. I did not take the old won ... A: It sounds like you bypassed the switch. Yes, there is no neutral in your heater because it is ...
|
| Safety | 1/25/2009 |
Q: I'm hoping you'd be willing to answer the following question about safety/code: Is it o.k. for the ... A: If the sub panel is rated for 125 amps then you need to run wire that is appropriate for 125 amps, ...
|
| front door sconces -- wiring | 1/25/2009 |
Q: A friend of mine called me to take a look at this: she is having work done on her house (not ... A: I need to know how you are measuring power, exactly how you did it and what type of voltmeter did ...
|
| Sub Panel Wire Size | 1/24/2009 |
Q: I have a few questions regarding sub panels. Is the amp rating of a sub panel supposed to be higher ... A: The wire running to a subpanel has to be rated for whatever that panel is rated for. No matter what ...
|
| Electrical Panel | 1/24/2009 |
Q: I have a 100 amp service fuse panel (amalgamated electric) that is full. Some 14/2 wire has been ... A: Where did you read that about the dryer? The concern I have is if you are overtaxing the 100 amp ...
|
| oven malfunction | 1/23/2009 |
Q: I have a frigidaire pro gas range #plgf659ec. It is only 16 months old. The "Bake" mode has failed. ... A: The first thing to check is that you are not in "time bake" mode. If you have verified that all the ...
|
| electrical | 1/22/2009 |
Q: I installed a programmable light switch for my outside lights, beside 2 other switches (3 switches ... A: All the switches should have the tabs snug against the box. If they are not, then yes you probably ...
|
| dryer throwing the main breaker | 1/22/2009 |
Q: I have a 5 yr. old Roper dryer. It runs on it's own 30 amp breaker. Recently, when the dryer is ... A: You could have a short in the motor or heating element(s). An amp-meter can be used to find out the ...
|
| Safety | 1/21/2009 |
Q: I'm hoping you'd be willing to answer the following question about safety/code: Is it o.k. for the ... A: You can have junction boxes or subpanels between the main breaker and the device. I am not sure ...
|
| 3 way switch gang box | 1/20/2009 |
Q: I am working with a new lighting installation in my basement and have never wired 3 way switches but ... A: First, if it is a 20 amp circuit you will need to run 12 gauge all the way through. Do not make the ...
|
| oven wire splicing | 1/19/2009 |
Q: I have an in cabinet, 96 Kenmore micro-oven combo #665.4433452. The wiring harness had a loose wire ... A: Excellent question. The answer depends on if you feel like you ever need to separate the wires ...
|
| GFI/Circuit breaker | 1/18/2009 |
Q: We did a bathroom remodel and a friend added a few gfi outlets, a light and an exhaust fan with a ... A: If this is the only bathroom, the lights and outlets can be on the same circuit. Otherwise they need ...
|
| old home wiring | 1/17/2009 |
Q: I am remodeling my kitchen. For 30 years the fridge has been on a circuit with 2 other receptacles ... A: Your new microwave will need its own circuit (20 amps). The refrigerator should be on its own ...
|
| Lamps and Bulbs. | 1/17/2009 |
Q: Is it ok to use a regular 60 watt bulb in a lamp that says requires a 3 way 150 watt incandescent ... A: The "type A" is the shape and size of the base of the bulb so you have to follow that. If the ...
|
| wiring bathroom fan/heater | 1/16/2009 |
Q: I want to put a timer switch on my bathroom heater. Currently I have wiring coming into a two ... A: It sounds like the black/white/ground is the source power. To verify, disconnect all wires and make ...
|
| Wire size | 1/15/2009 |
Q: I am running 60 amp panel to the garage ,from my 100 amp house panel . It is approx 180 ft of wire . ... A: #6 is very, very close to the max voltage drop allowed by the NEC. Note the words "max allowed" ...
|
| 2 outlets not working | 1/12/2009 |
Q: This is the previous question I sent: Boyfriend installed a new big computer monitor which blew the ... A: Yes, we do have secrets but unfortunately if I tell you what they are they cease to be secrets. j/k. ...
|
| installing 220 vlt outlet | 1/10/2009 |
Q: I am trying to put a 220 volt outlet in my basement for my dryer. The wiring is already there I ... A: The two hots get connected to the two straight prongs and the neutral gets connected to the the "L" ...
|
| Burnt component smell at disconnect breaker | 1/9/2009 |
Q: Overjoyed to have found this resource, thanks in advance for any insight. Basic Issue: ... A: You do not add the two phases together, so your 95 amps is incorrect. However, your 47 and 46 amps ...
|
| voltage in outlets | 1/8/2009 |
Q: Some of our home outlets read 145-150 volts when we checked them. Is this a problem? How do we ... A: You did not say, but I will assume you are in the U.S. This could be a problem for some loads and ...
|
| Electrical Fluctuation | 1/7/2009 |
Q: The electricity in my house fluctuates whenever anything is turned on. The strange thing is if you ... A: It sounds like there is a circuit that is wired from two different sources and perhaps shares a ...
|
| Thermostat will not follow commands | 1/7/2009 |
Q: I have a hot water baseboard heating system and I changed from a conventional thermostat to a seven ... A: I could not locate the model for the White Rodgers. But at this point you need to find out what ...
|
| electrical wiring | 12/16/2008 |
Q: 1 - in the bathroom there is a combo light switch/single outlet recepticle. The light switch works ... A: The outlet could have a broken or loose connection in the box, or the outlet itself is worn out. Do ...
|
| Breaker? | 12/15/2008 |
Q: Tonight, our kitchen, garage, and living room lights went out. This has happened a few times in the ... A: That is an awful lot to be on one breaker. The breaker has probably been overloaded for too long and ...
|
| AFCI Breaker | 12/14/2008 |
Q: I have a question, is it possible in a circuit with a AFCI Breaker that some of the outlets will ... A: Are AFCI breakers required in garages in your part of the country? It seems like they would be a ...
|
| Very low power | 12/13/2008 |
Q: I live in a duplex and each unit has separate meters. One night around midnight our lights were ... A: There are too many possibilities for you to be expected to fix this problem. You need a good ...
|
| electrical panel | 12/13/2008 |
Q: I am from Ontario Canada and I'm considering moving my bathroom to a much larger room. The problem ... A: I am not familiar with codes in Canada, but I would not recommend having the panel inside the ...
|
| ceiling fan with light with remote and three way switches | 12/12/2008 |
Q: I am replacing a hallway light with a remote controlled ceiling fan with a light. The light is in ... A: You should of connected the black and white marked line to the same wires that the old light was ...
|
| AC wiring | 12/12/2008 |
Q: We are selling our house and the buyer's home inspector identified a double tapped circuit breaker ... A: Placing two wires under the same breaker is not allowed. It sounds like someone took one leg of your ...
|
| exterior christmas lights | 12/10/2008 |
Q: I am running christmas lights on my property. It is a fairly short run using a 9' extension cord to ... A: This is a very good question. Technically the correct answer is no, however; Christmas lights ...
|
| trip breaker | 12/10/2008 |
Q: I installed some new sconces, new electrical wiring and new light switches. I used new 12 guage ... A: It sounds like you have the switches bypassing the lights so when you turn them on you have a direct ...
|
| Bathroom outlet suddenly not working. | 12/6/2008 |
Q: ..this morning I noticed the outlet in the bathroom was not working -- I have my cats water ... A: This should be on a gfci breaker or outlet. The gfci outlet could be located in that bathroom, ...
|
| Circuit goes dead when controlling Circuit Breaker is 'ON | 12/5/2008 |
Q: An answer to yourThanks for answering this if you can. I have a 15 amp gfi breaker which controls ... A: Feel free to ask as many questions as you like. What you should have is two 3-way switches and one ...
|
| Circuit goes dead when controlling Circuit Breaker is 'ON" | 12/5/2008 |
Q: An answer to yourThanks for answering this if you can. I have a 15 amp gfi breaker which controls ... A: It is most likely a loose connection and I have never seen a loose connection tighten itself. In ...
|
| Moving an existing electrical outlet to another room | 12/3/2008 |
Q: My garage is finished with drywall and one electrical outlet (with the exception of the garage door ... A: If you have an AFCI breaker for the bedroom this would not work well. Even if you do not have AFCI ...
|
| Wiring Honeywell truesteam humidifier | 12/2/2008 |
Q: I am installing a Honeywell steam humidifier to a Lennox dual fuel heat pump/gas furnace. The ... A: When I said four wires to the humidistat, I meant to say four wires to the humidifier. Your two ...
|
| electrical problem at home | 12/1/2008 |
Q: we had the washing machine, dishwasher,tv, and also the blowdryer on in our small 2 bedroom house ... A: Normally your dishwasher and garbage disposal are not on a gfci, and they are not a circuit together ...
|
| Wiring Honeywell truesteam humidifier | 11/29/2008 |
Q: I am installing a Honeywell steam humidifier to a Lennox dual fuel heat pump/gas furnace. The ... A: All you are doing is breaking the "G" circuit (which is the fan) and supplying an "R" and "C" ...
|
| electric | 11/29/2008 |
Q: An outside outlet is dead, tested it with both a meter and a lamp. Switched out the 3 wire unit ... A: If you pulled out the outlet and there was no power to the wires then replacing it would not be the ...
|
| Wiring Honeywell truesteam humidifier | 11/27/2008 |
Q: I am installing a Honeywell steam humidifier to a Lennox dual fuel heat pump/gas furnace. The ... A: Scan the diagrams for me. Normally you would have the humidifier turn on when the heat is called ...
|
| dryer plug | 11/26/2008 |
Q: turned on my dryer smelt burning,red wire was melted a bit in outlet,turned off breaker and the red ... A: With the circuit breaker off; Strip the wire back and cut off burnt part. Reattach firmly to outlet ...
|
| Plugging In Dryer Caused Loud Pop | 11/26/2008 |
Q: First, thanks in advance for your help! My problem is that my tenant just purchased a washer and ... A: The dryer should be on its own fuse or breaker, so it should not affect any other circuits. If it ...
|
| Help me! | 11/25/2008 |
Q: I am wiring a ceiling fan that has a variable speed and dimmer light the wiring coming out of the ... A: Okay, what I need you to do is tell me where power is at (hot and neutral) and you will need a ...
|
| partial power outage and surging in mobile home | 11/23/2008 |
Q: Sometimes when it goes out if flickers many times and other times it just goes out and sometimes ... A: It sounds like either a main breaker is going bad, a few breakers are going bad, the panel is pitted ...
|
| Circuit breaker problem? | 11/21/2008 |
Q: My wife was drying her hair in the master bath when the dryer shut off. No breakers tripped - yet ... A: It sounds exactly like a gfci outlet or breaker tripped. You should go to the main panel and check ...
|
| House lost neutral | 11/21/2008 |
Q: An electrical crew cut the neutral going to my house form the street (underground utilities). Most ... A: This is very serious! It sounds like they may have cut through the cable and shorted the wires ...
|
| home wiring | 11/20/2008 |
Q: While replacing the light fixture in the stairway to the basement, i fount that it uses the old knob ... A: It is possible that they are using the same neutral and you have reversed polarity. It is easy to do ...
|
| Electric Heating Relays | 11/20/2008 |
Q: A friend of mine has 3 - 2000 watt fan forced electric heaters installed in his living room and they ... A: So that is 4 - 2000 watt heaters you want on one t-stat? The first thing you need to establish is ...
|
| Dryer Plug Issue | 11/19/2008 |
Q: I put my dryer in storage when I moved into my folks home after they passed away. Their old dryer ... A: Kay, Your dryer has a 30 amp cord on it, which is correct. Your parents have a 50 amp outlet and ...
|
| apartment wiring | 11/19/2008 |
Q: i am currently renting an apartment where my roomate and i have to constantly reset the breaker ... A: Typically the lighting and outlets are put on separate circuits. A breaker that continues to trip is ...
|
| WIRES | 11/18/2008 |
Q: hi my partner tried to put up a new light fitting he also replaced the old switches with dimmer ... A: It sounds like either a breaker tripped or the dimmer switch is no longer working. I would start by ...
|
| Electrical Amperage in our home | 11/18/2008 |
Q: We have a 3200 Sq.ft home in Cypress, Texas. (near HOuston) When the air conditioning comes on the ... A: The size of the main depends on a load calculation that is usually required by the city or county ...
|
| adding a dishwasher | 11/15/2008 |
Q: I just purchased an older home and it doesn't have a dishwasher.There is a wire ran for under ... A: Your dishwasher uses enough watts to need its own circuit. The dishwasher should not be on the ...
|
| lighting switch- radio controlled | 11/14/2008 |
Q: I am looking for a lighting switch that can control 1000W of lighting. The circuit is structured as ... A: The same voltage drop to the switch still applies to the wire going to the lights so the wire size ...
|
| German Dryer Not Hot Enough | 11/13/2008 |
Q: I bought a German Brand dryer (Bosch) n the States and it's not getting hot enough to dry ... A: In your first question you said you had fuses, now you say you have breakers. Do you have a breaker ...
|
| Electrical box for a florescent fixture | 11/12/2008 |
Q: I am trying to install a florescent light fixture in my laundry room. The electrical box that held ... A: Some florescent light fixtures do not require a separate box for the wiring. You can do the wiring ...
|
| wiring | 11/9/2008 |
Q: I have my refridge on a 20 amp circuit as well as 3 other outlets is there any way to make sure the ... A: If you really want to know for sure you will have to open each outlet and trace the wire around the ...
|
| esb avalon16 residential tanning bed electrical help | 11/7/2008 |
Q: We have a esb avalon16 bed that has always worked great but now shuts off automatically every couple ... A: Call a qualified electrician before you start a fire. Unplug the unit until you can get an ...
|
| Non-working receptacles | 11/6/2008 |
Q: where a "master electrician" once lived. Apparently this guy loved outlets, because my house if ... A: I love Cape Cod homes. However, a custom job by a homeowner or handyman is an electricians worst ...
|
| Garage GFCI Tripping | 11/4/2008 |
Q: I have four florescent light fixtures each with two 4' long 40 watt bulbs in them hanging in my ... A: You should keep the GFCI in the garage because of code. However, the lights do not need to be on a ...
|
| open ground fault | 11/2/2008 |
Q: I am wiring a basement and am having a problem with the last three of four outlets, two boxes of two ... A: Each outlet needs it own ground wire connected to it. In the first box you will take the incoming ...
|
| Electric heat 4 wire thermostat question ... | 10/28/2008 |
Q: I tried another expert, but they are not familiar with electric heat - thank you so much for your ... A: Without looking at your wiring I cannot tell you if you have created a dangerous situation or not. ...
|
| Hot tub wiring | 10/27/2008 |
Q: i am wiring a hot tub that requires 220 #6 4 wire 3 + ground my panel currently has 5 i belive 220 ... A: It sounds like you have an electric oven and maybe a separate cooktop, water heater, dryer, and your ...
|
| recessed lighting | 10/26/2008 |
Q: I am instaling four 5 inch can lights in my living room. I have a spare dedicated gfi outlet that I ... A: Technically you cannot add 12 gauge to the end of 10 gauge. I would just go ahead and feed the ...
|
| installing a new pull switch on ceiling fan/light | 10/25/2008 |
Q: I am installing a new pull switch on my ceiling fan. Prior to installing the switch and with the ... A: Did you remove the ceiling fan to replace the pull switch or did you leave it in place? The pull ...
|
| bathroom GFCI circuits | 10/25/2008 |
Q: I have rewired many baths, and usually have all switches (to lites, exhaust, etc) protected by the ... A: No, not according to the NEC. The light over the sink and the fan are usually not on the same ...
|
| wiring | 10/24/2008 |
Q: i turned the power off to my bathroom from my breaker box when i was unscrewing the wires the and ... A: It sounds like the breakers are not marked correctly. Remember that the bathroom light is most ...
|
| power to my shop | 10/23/2008 |
Q: I've decided to get some power to my shop.Outlets,lights to run saws, sanders ,small ... A: If you bury the wires in conduit you do not need direct burial wire. Of course you can run direct ...
|
| Wire from my home to my shop | 10/21/2008 |
Q: I just bought a home that has 6 awg al xlpe 600 volts wire running from the home to a shop 200 ft ... A: Your 6 awg is effectively 10 awg at that distance which is good for 30 amps. So your 100 amp panel ...
|
| TRAVEL TRAILER HOOK UP AT HOME | 10/19/2008 |
Q: I AM TRYING TO HOOK UP ELECTRIC TO MY CAMPER.I GOT A SEPERATE BREAKER BOX. DISTANCE FROM MAIN BOX AT ... A: This is a common problem with campers. You need to know your amperage needs and voltage needs. If ...
|
| 1 second delay when turning on lights | 10/17/2008 |
Q: 2 days ago I noticed a 1 second delay when switching my daughters room light on. Then yesterday the ... A: The switches most likely need to be changed. They are both probably the same age and get about the ...
|
| nameplate | 10/16/2008 |
Q: Does a nameplate on equipment tell you if you need a neutral wire?I know ac uses 220 and doesn't ... A: If the equipment uses 120 and 220 volts it needs 3 or 4 wires. An electric dryer uses 220v for the ...
|
| main amperage requirements in resi | 10/16/2008 |
Q: I own an apartment with 60amp service... How do I determine the amount of main service I need... I ... A: You could do a load calculation to find out the service you need. Simply adding your loads is not ...
|
| a.m. radio noise from house wiring | 10/15/2008 |
Q: M. radio at my house. I notice that when I turn on an outside light the noise gets dramatically ... A: There are many factors that can contribute to the disturbance of Amplitude Modulation (A.M.), which ...
|
| ceiling fan/ light problem | 10/14/2008 |
Q: I replaced a broken double switch that controlled a ceiling fan and its light. I wired it exactly ... A: Does the switch have two screws on both sides? If so, then you have wired the hot and the fan to ...
|
| 4 wire drier plug | 10/9/2008 |
Q: would the ground and nuetral be hooked on the same post at drier? A: On a three prong dryer the ground and neutral are bonded together. The ground is attached to the ...
|
| Remodeling kitchen adding wall oven and cooktop | 10/7/2008 |
Q: Our home was constructed in 2000. Currently we have an electric 4 burner range with a self cleaning ... A: The NEC allows both the cooktop and oven to be on the same breaker, as long as the breaker can ...
|
| 200 vs 100 amp service | 10/6/2008 |
Q: We moved from a house with a 200 amp service to one with 100 amp service. Our electric blanket ... A: A quick test would be to use a voltmeter in the same outlet as the one the blanket is plugged into. ...
|
| House Main Breaker | 10/5/2008 |
Q: Our apt. has only one breaker between the meter , and the Apt, upstairs. I cannot determine the amp ... A: Two 20 amp breakers with single lever is called a 20amp double pole breaker and it is rated at 20 ...
|
| Sub Panel | 10/3/2008 |
Q: question is ... I am running a 125 subpanel around 125 feet from the main panel ... what size feeder ... A: Normally a 125 amp panel requires #2 copper. However, your long distance means that you need to go ...
|
| Dayton G73 Electric Heater | 10/3/2008 |
Q: In reference to the Murray/Alex Napier exchange regarding the above. To review - the Dayton Heater ... A: This sounds like a pure 220volt heater, meaning that is does not require 120volts. If so, black from ...
|
| wiring mobile home | 10/1/2008 |
Q: We just put a pole outside for new electric service. The electrician we got put a 200amp breaker on ... A: There are too many unknowns for me to tell you if it safe or not. You should of pulled a permit for ...
|
| Re-wiring a pump | 10/1/2008 |
Q: I recently replaced my submersible well pump when I had a new well drilled on my property. The old ... A: Get a voltmeter and determine the voltage of the pump and which wires are carrying what volts. ...
|
| two or more undercabinet lights in series | 9/30/2008 |
Q: I am wiring two halogen under cabinet lights, with each having it's own switch. Do I need a fourth, ... A: If you are using the built in switches then you need to run one black, one white, and one ground to ...
|
| adding new wiring | 9/30/2008 |
Q: The load-bearing walls are cinder blocks with wire metal lath and plaster. The non-load-bearing ... A: There is a product called "Wiremold" that goes on the outside of the wall. This may be what you will ...
|
| Trane shop heater wiring | 9/29/2008 |
Q: Old, hanging Trane shop heater, natural gas, 115v. Fan motor went bad, ordered a replacement from ... A: The four wires indicate that it is either multispeed or requires a capacitor. The wiring diagram on ...
|
| two or more undercabinet lights in series | 9/28/2008 |
Q: I am wiring two halogen under cabinet lights, with each having it's own switch. Do I need a fourth, ... A: You will have black from the outlet go to each switch. From the other side of the switch you will ...
|
| Dryer wiring problem | 9/27/2008 |
Q: I just remodeled an old cabin and put 10-2 wire in for the dryer instead of 10-3. The walls have ... A: Mark, There is product called Wiremold that you can run on the outside of the wall. What you need ...
|
| wiring multiple outlets | 9/26/2008 |
Q: How would i wire multiple outlets or do they have to be home runs? A: This depends on the application. For example, bathroom outlets need to be on their own "home run", ...
|
| 220V Single Phase machine with Three phase socket? | 9/25/2008 |
Q: I have an espresso machine that requires single phase 20amp power at 60hz...now I have an outlet ... A: You need to change the outlet to match the plug on the espresso machine. Typically you have two flat ...
|
| electricity goes out and later comes back | 9/24/2008 |
Q: I would be grateful if you can help me with the following problem. On a regular basis (weekly, ... A: When the power goes out you will need to trace the circuit and check each junction box and fixture ...
|
| hvac | 9/24/2008 |
Q: I have a heat pump that is about 23 years.American standard, I am in the process of changing from ... A: You will need to physically look at which wire goes to the reversing valve, which wire goes to the ...
|
| 3-way rocker switch | 9/22/2008 |
Q: I have the same problem in all areas with a 3-way. I am using leviton Decora switches. My house is ... A: The new 3-way switches are wired differently than some of the old ones. If you replace it wire for ...
|
| wiring in our new house melted our dryer | 9/21/2008 |
Q: Greg, Hello! Help! We just moved to a new (old) house and the first few days when I was doing ... A: The two causes that I can think of are the outlet is wired wrong and you got 220 volts on the ...
|
| service entrance | 9/21/2008 |
Q: My entrance coming in behind the meter goes in to a cylinder fused square d switch box rated at 100 ... A: It sounds like you need an electrician to inspect your wiring and you may need to pull a permit. ...
|
| Upstairs lighting circuit not working ? | 9/18/2008 |
Q: The problem is that the bathroom light was switched on which in turn blew the bulb, the bulb was ... A: The voltage pen tester only detects if voltage is present, not if you have a good circuit. If you ...
|
| 220v line ? | 9/18/2008 |
Q: is there any way i can run a 220v line split off of my stove for a dryer,i know that it wont be ... A: You can do that for a stove and oven, and you can do it in the garage for loads that will not be ...
|
| Upstairs lighting circuit not working ? | 9/17/2008 |
Q: The problem is that the bathroom light was switched on which in turn blew the bulb, the bulb was ... A: Three ways to approach this problem: Start at the main power and work your way towards the light. ...
|
| Hit Electric Wire in Ceiling with Drill | 9/15/2008 |
Q: We were installing large hanging hooks in our garage ceiling and used a regular stud finder, which ... A: I am glad to hear you are getting an electrician out there. The danger depends on several aspects. ...
|
| Electric furnace wiring | 9/13/2008 |
Q: Greg I'm installing a 20kw electric furnace and have worked out the min circuit breaker should be ... A: Go with the 2 gauge. A two-pole breaker connects to both legs so you can get 240 volts between the ...
|
| Ceiling fan wiring | 9/11/2008 |
Q: I'm replacing a light fixture controlled by a wall switch with a ceiling fan/light. Present wiring ... A: Do not worry, this is not a stupid question. Are the two lines present at the switch box or light ...
|
| Two Switches 1 Live Line | 9/11/2008 |
Q: Currently I have 1 switch at the top of the stairs and it turns on the lights to the Rec Room. It is ... A: If that switch only has two wires coming to it then it sounds like the power goes to the light box ...
|
| Lights | 9/10/2008 |
Q: My husband moved a window unit from one window to another. It had been working fine all day. Then ... A: The unit is plugged into a circuit that cannot properly support it. You will need to either place ...
|
| Questionable wiring | 9/7/2008 |
Q: I recently discovered some 14 gauge wiring on a 20 amp circuit in my house. The 14 gauge seems to ... A: If the lights were added on, it should not be too difficult to change the wire. With the power off, ...
|
| Home Sauna Wiring | 8/31/2008 |
Q: I'm building a sauna in a shed behind my house (120 feet from the main electirical panel). The ... A: You are very close on this one. The max length, given the voltage drop, is 119 feet with #8. If ...
|
| How to replace an receptacle? | 8/31/2008 |
Q: I found an old 3-prong socket (with one connection) in my new home that appears to be an old socket ... A: First you should find out if it is 220 volt or 110 volt. This will help you if you decide to use the ...
|
| wiring outside the house | 8/30/2008 |
Q: Is there any way to reconnect to a short line coming through the basement wall? Our old well pump ... A: I guess that is why they are plumbers and not electricians. You are going to need to find where the ...
|
| subpanel | 8/30/2008 |
Q: the subpanel in my detached garage did not pass inspection because the main breaker did not have a ... A: You gave me the model of the subpanel, which does not have a main breaker. I believe you are ...
|
| WELDER HOOK UP | 8/29/2008 |
Q: I NEED TO RUN A 240 V CIRCUIT TO A SYNCROWAVE 200 WELDER. ITS RATED OUTPUT IS 150 AMPS AT 26 ... A: The voltage drop should not be a concern for 60 feet. I would recommend #4 gauge and a 60 amp ...
|
| Lennox start capacitor not grounded | 8/29/2008 |
Q: I believe - red, yellow, green wires) recently burned out on my 10+ old Lennox outside air unit. A ... A: Start caps have a tolerance whereas run caps do not. The start cap should have a % of tolerance ...
|
| wiring three way to outlets! | 8/28/2008 |
Q: I'm Currently working on renovating my house, In my upstairs bedroom i want to have my recepticals ... A: Here are the different ways to wire it according to where the power comes in and if the light is ...
|
| wire length in main panel | 8/27/2008 |
Q: I am wiring a new 125 Amp Murray main lug panel. I was taught in an electrical course 20 years ago ... A: You can have a wire nut in the panel. Two schools of thought; you get to pick which one. Bring the ...
|
| washer and dryer grounding??? | 8/27/2008 |
Q: ..I just got an old washer and dryer and I'm wondering if the green wire hanging from the back of ... A: The middle one should be the neutral, which is white on the dryer. Remember to bond the neutral ...
|
| washer and dryer grounding??? | 8/26/2008 |
Q: ..I just got an old washer and dryer and I'm wondering if the green wire hanging from the back of ... A: That green wire gets connected to your cold water line. It is most likely that the people who owned ...
|
| electrical problem | 8/26/2008 |
Q: the other day while vacuuming my breaker tripped. I unplugged the vacuum and went to the breaker ... A: If the bathroom outlets are on the same circuit and have power then it would not be a circuit ...
|
| electric thermostat | 8/25/2008 |
Q: I want to move my thermostat from the electric heater to a wall mount. I have run 12-2 wire to the ... A: It depends on whether the t-stat is single or double pole. And, are you sure the 12-2 is big enough? ...
|
| wiring in a ceiling fan | 8/25/2008 |
Q: Greg, I am looking to install a ceiling fan in a bedroom that has no ceiling fixture. There is a ... A: The way I told you to wire it would make the outlet hot on both upper and lower prongs. If you are ...
|
| wiring in a ceiling fan | 8/24/2008 |
Q: Greg, I am looking to install a ceiling fan in a bedroom that has no ceiling fixture. There is a ... A: I would suggest running wires from your switch to the attic and across to where you want your fan to ...
|
| Replacing Furnce | 8/23/2008 |
Q: We are replacing a 15yo furnace with more efficient model. Terrible time deciding which brand. ... A: Having been factory trained by Carrier, worked for factory authorized Lennox - Trane & Carrier; And ...
|
| Capacitor | 8/22/2008 |
Q: If a blower motor (for an air handler) asks for a 5mF/370V cap, would it be a big deal to connect a ... A: Run caps need to be exactly what the motor calls for or else you will have premature burn out of the ...
|
| need home generator connection to house help | 8/21/2008 |
Q: I have a 5500 watt gas electric generator. I have not had time to get an electrician to install the ... A: "Do you think that will work as a temp fix thru this storm?" All indications that I have seen you ...
|
| Hard wire do wall plug | 8/20/2008 |
Q: I bought a range hood that was supposed to have a plug but that instead has 2 wires coming out of it ... A: I take it that you are not replacing an existing hood, but adding a new one that never had any ...
|
| Plugs not working | 8/18/2008 |
Q: The plugs in my two back rooms don't seem to work. I have tried flipping the switch at the circuit ... A: The testers that light up merely tell that there is voltage present, but not how much. It also ...
|
| One Circuit two breakers | 8/17/2008 |
Q: My garbage disposal circuit requires that I turn off two separate breakers and siimultaneously to ... A: No, this is not normal. Somehow you have that tied into another circuit. You will need to back track ...
|
| New switch | 8/17/2008 |
Q: I want to add a switch and an outlet to an existing line of outlets. However, I only want the ... A: Yes it is possible. With the power off, run your romex (12/2) from the switch to the outlet. You ...
|
| Outside Garage Lights | 8/16/2008 |
Q: Have a problem with outside garage light pair, standard builders’ grade fixtures from Lowes: Both ... A: Mike, This is an old trick that sometimes works. We usually do not reveal it because it is ...
|
| Shed feeder question | 8/15/2008 |
Q: Hughes: I just built a 12 x 16 shed and pulled my electrical permit to wire it up. I have a ... A: I am surprised that the inspector is allowing you to put in a 100 amp service panel on #4 wire. This ...
|
| Outdoor GFCI got wet | 8/14/2008 |
Q: Greg, My father and I installed a GFCI line outside for my new pool. Over the past 3+ weeks, it has ... A: If the pump was plugged in and the cover was open to accommodate the plug then it is very possible ...
|
| Circuit out | 8/13/2008 |
Q: After a recent storm, the main switch activated. On turning it back on, the switch activated again. ... A: Bill, That is a good way to troubleshoot. If the breaker trips with no load on the transformer you ...
|
| GFI Outlet | 8/12/2008 |
Q: I have just replaced a GFI outlet in my kitchen. I believe i have everything connected correctly ... A: You should have the hot wire connected to "Line-Hot" or "Line-Black", the neutral to "Line-Neutral" ...
|
| Running wiring to the shed | 8/11/2008 |
Q: I'd like to run 20amp wiring from the breaker box, through the basement and outside - then running ... A: Many cities allow a home owner to do an electrical upgrade under builder-owner as long as a permit ...
|
| Running wiring to the shed | 8/10/2008 |
Q: I'd like to run 20amp wiring from the breaker box, through the basement and outside - then running ... A: Greg, Here are some things to think about: 1. Is the pump 110 volts or 220 volts? 2. Do you think ...
|
| 208 VAC | 8/9/2008 |
Q: We are a non-profit that just received a donation of a forklift and battery charger for our ... A: 1.The diagram was scanned at too low of resolution for me to read. I can see that it is telling us ...
|
| Dimmer and Recessed Light | 8/8/2008 |
Q: I installed nine (9) recessed lights in our living room. The wire used is Romex 12 Gauge (Yellow ... A: The actual wattage drawn is a result of the actual voltage supplied. The resistance of the filament ...
|
| 24v supply for humidifier | 8/8/2008 |
Q: I am (re)installing an Aprilaire 700M humidifier on my Bryant 350MAV furnace. (The old one, an ... A: The "HUM" is for your humidifier connection. This is only energized when the furnace in is the heat ...
|
| Grounding strap concern | 8/6/2008 |
Q: The original DirecTV installer did not use exactly one of the points in an article "Grounding ... A: I do not enough information from that picture to give you advise. You need to find out how ...
|
| three-way switch wiring issue | 8/5/2008 |
Q: have three way switch circuit that is giving me a problem. Situation: I have a three switch to ... A: Newer three-way switches are wired differently than older three-way switches. If you replace an ...
|
| mobile home | 8/5/2008 |
Q: Hughes, How difficult is it to change the aluminum wiring in a mobile home to copper wiring. Also I ... A: Aluminum wire expands and contracts more than copper does, so it is more prone to become loose and ...
|
| TV turns off when Stove is turned on | 8/4/2008 |
Q: This is a problem that has happened to me in two separate apartments. It only started after I ... A: It sounds like your surge-protector is doing it's job. An A/C draws a lot of power when it turns on ...
|
| MOBILE HOME ELECTRICAL | 8/3/2008 |
Q: LOST POWER TO A 220 AC UNIT, AND ALSO REFRIGE AND FREEZER, AND OTHER SPOTS AROUND THE HOUSE, WHAT IS ... A: The first place I would look is in the main panel. It sounds like either a main breaker going bad or ...
|
| replacing a receptacle | 8/3/2008 |
Q: before replacement, when the light switch was in the off position, the receptacles had power to only ... A: There is a small metal tab on the side of the outlet where the screws are that needs to be broken. ...
|
| installing new ceiling fan | 8/2/2008 |
Q: I am trying to install a new ceiling fan/light combo. The existing fan uses the pull chains to ... A: This means that power is most likely being supplied at the light fixture and the two wires to the ...
|
| swamp cooler motor | 8/2/2008 |
Q: I bought a 1 yr old cooler this summer from a friend who I guess left it undrained last winter, so I ... A: The first thing to check is the voltage supplied to the motor. If that is okay then you did the ...
|
| Residential remodel wiring | 8/1/2008 |
Q: I have recently bought an older home that had some older updates, including the electrical. We had ... A: It will probably be better to isolate the bedroom outlets like you are thinking. This will also ...
|
| expanding from one outlet to three | 7/30/2008 |
Q: I am renovating my bathroom. I have one standard outlet on the opposite wall from the sink. I want ... A: The first thing you want to check is if this outlet is on a GFCI breaker, or fed from another GFCI ...
|
| Stackable W/D | 7/29/2008 |
Q: My husband pulled out a stackable washer/dryer unit to replace the dryer vent. After it was done, he ... A: Interesting problem. It sounds like a wire came loose, or the plug is not making good contact in the ...
|
| Garage Door Opener (GDO) | 7/29/2008 |
Q: I had a motor "start" capacitor blown on my 20 year old model 2200 Stanley GDO. A replacement ... A: This sounds like a start capacitor. A run capacitor has an exact micro f. rating. A start capacitor ...
|
| Need subpanel for new A/C system | 7/27/2008 |
Q: I have an 8.5-yr old house with a 3.5 ton Goodman A/C system going bad. I have 2400 sq. feet and 2 ... A: Without seeing the job there is no way for me to estimate a cost. There are too many variables. ...
|
| no power along one wall in garage | 7/26/2008 |
Q: I have NO experience in wiring. I was working in my gagrage last week when I noticed that I had no ... A: It sounds like there is a good chance the breaker needs to be replaced. But the outlets need to be ...
|
| Ground rods, GFI & Arc-Fault breaker questions | 7/24/2008 |
Q: I am building a 24x60 (with 14x60 second floor) workshop next to my house and it is wiring time. I ... A: Ken, For the ground rods you should consult your local building inspector because each area can ...
|
| Vent Pipe Shock | 7/24/2008 |
Q: I am a journeyman electrician with years of troubleshooting experience. Recently a customer was ... A: What were the two vents for? Are the vents well grounded? Is one well grounded and the other not? ...
|
| Wire capacities | 7/23/2008 |
Q: Need a direct answer. After asking several electricians I am confused. I am installing a sub-panel ... A: If local codes are stricter than the NEC, the local codes supercede the NEC. Which is why it is good ...
|
| Wire capacities | 7/23/2008 |
Q: Need a direct answer. After asking several electricians I am confused. I am installing a sub-panel ... A: What is the subpanel rated for? You need to run the wire size that is appropriate for the rating of ...
|
| Running electricity to an outside brick shed | 7/22/2008 |
Q: i have just moved into a new house and have a brick shed which is about 3 feet from the main ... A: Drilling the holes is okay but you would need to run conduit. Anytime you have electrical wires on ...
|
| Electrical Wiring problem | 7/21/2008 |
Q: Not a home wiring issue but this is the closest I could find. Hope you can help. My neighbor has a ... A: It is possible that you have a loose or broken ground wire. Try plugging the motorhome into a ...
|
| bad recptacle | 7/21/2008 |
Q: I have a circuit in my house that that covers three rooms. Two rooms receptacles and lights work ... A: It is a good idea to have the bathroom outlet on it's own gfci circuit. However, it sounds like you ...
|
| Breaker question & kiln | 7/20/2008 |
Q: Greetings! I hired a professional electrician to add a 50 amp circuit breaker to my home service ... A: How long does the kiln run at (basically) 50 amps? If the kiln runs at 50 amps for 3 hours or more ...
|
| 220V electric shower | 7/20/2008 |
Q: I will appreciate very much if you can help me with this problem : I´m a resident in a ... A: I looked at the manual, but I do not understand the language, and it appears that there are two ...
|
| A problem I don't understand.... | 7/17/2008 |
Q: I removed all my basement lights and decded to install new ones. I installed new boxes and wire from ... A: Ground wires can have voltage due to voltage coming up from the earth through the ground rod, from ...
|
| Moving ceiling light fixture | 7/17/2008 |
Q: My current ceiling light fixture is not centered to our living room. I'd like to move it ... A: If you have good attic access then this is not difficult. You will need to run the romex from the ...
|
| garbage disp and dishwasher | 7/16/2008 |
Q: our switch for the garbage disp has been sticky latly and you have to really push hard to get it to ... A: It is possible that he tripped a gfci outlet or breaker. Check the kitchen and bathroom for a gfci ...
|
| Switched outlet | 7/15/2008 |
Q: I have an outlet with 4 receptacles, and power feeding the outlet box. one black, one white, one ... A: First you want to establish if the wires from the switch are hot or not. And you want to establish ...
|
| Toggle switch connection to existing outlet | 7/15/2008 |
Q: I have installed an exhaust fan under the eave of my house to vent kitchen smoke via existing ... A: You could replace the outlet with an outlet that has a switch, or you can install a cut-in box near ...
|
| electrical - sockets and lights not working | 7/14/2008 |
Q: Can you please help? In the bedroom: Lights for the closet and above the sinks will not come on. ... A: Were you experiencing a problem that caused you to mess with the electrical panel? Mosts likely a ...
|
| circuit box | 7/13/2008 |
Q: dryer not working - tried flipping switches in circuit box - 2 for kitchen had white test buttons - ... A: Yes, if the test button is on the circuit breaker it will trip the breaker. If a breaker trips for ...
|
| circuit box | 7/13/2008 |
Q: dryer not working - tried flipping switches in circuit box - 2 for kitchen had white test buttons - ... A: There should be a reset button for the two. If the reset button does not allow you to turn the ...
|
| Lighting System for church outdoor Poster | 7/12/2008 |
Q: Our Local church is planing to light up an advertising poster fixed on the outside part of the ... A: Wow, a lot to answer here. First I would suggest using a photocell instead of a timer. This way you ...
|
| CEILING LIGHTS | 7/11/2008 |
Q: I HAVE TO SAY I DO NOT KNOW MUCH ABOUT ELECTRIC. BUT I TURNED MY BREAKER OFF AND CHANGED FIVE LIGHTS ... A: Yes, ground can actually be hot. Which is why electricians are taught to use a voltmeter before ...
|
| electrical panel | 7/9/2008 |
Q: my 30 year old house had an old heater that had its own small box with two 220v circuits. I ... A: You will need to run it to the main panel. The existing 220v circuit has been broken down into two ...
|
| Confused about wiring my new kenmore H2 Dryer | 7/8/2008 |
Q: The dryer came with the standard three prong cord. Delivery guys said i had to buy the three prong ... A: Good question and I am glad you asked. The 4-prong is the way the National Electrical Code wants us ...
|
| all home air fan | 7/8/2008 |
Q: the fan is a few months old turns on, will run and then after a while shuts off, ckt breaker does ... A: Is it a "whole house" fan that takes air from the house and blows it into the attic, or an "attic" ...
|
| Fixing a someone elses Mistake | 7/7/2008 |
Q: Hey I was installing a new panel box in my 1938 home when I noticed something odd. I have a 220v ... A: You should check local codes because you probably do not have to have the 50a gfi disconnect fed ...
|
| house wiring | 7/7/2008 |
Q: have a 4" box with a three wire that controls my light on my stair landing also from this box comes ... A: Let me see if I understand this correctly. It sounds like your 3-wire switch is a 3-way switch that ...
|
| Main breaker in subpanel keeps tripping | 5/28/2008 |
Q: I have a lot of info to give so I will give the question first. The 2 hot bars in a breaker box ... A: When you rewired your house you should of updated the panel to 200 amp service. To answer your ...
|
| loose neutral | 5/28/2008 |
Q: The lights in my master bedroom dim and stay there when a small appliance such as an iron is ... A: It is not uncommon on older homes to have the lights dim when a clothes iron is plugged in on the ...
|
| combo switch | 5/27/2008 |
Q: "I am having trouble installing a new combo outlet...the outlet is a combo switch/outlet..I have ... A: You will need a voltmeter to do this correctly. Simply trying wire configurations is dangerous. If ...
|
| Location of Breaker Box | 5/26/2008 |
Q: I an currently living in Colorado and my wife and I are searching for a home. I've have noticed ... A: Charles, Where I live all main breaker boxes are mounted on the outside. We have no basements. ...
|
| Oversizing electrical wire | 5/25/2008 |
Q: I ran 10g wire for a Reiker Heater ceiling fan, designed to give out 5,000 btu of heat. Ten guage ... A: The 10 gauge wire is okay. The circuit breaker is there to keep the device from running at too high ...
|
| Wiring a new receptacle from single-pole switch | 5/25/2008 |
Q: I am trying to add a receptacle near a new work box that currently has a single-pole switch in it ... A: You will need to find out which black wire is the "hot" wire and which one feeds the light. Turn ...
|
| Wall Switch on celing Fan | 5/24/2008 |
Q: This gives me the option of speeds from "blow you away"...to "pleasant breeze". I'm the nervous ... A: A dimmer switch generates heat because it acts like a resistor in series with the fan. How much ...
|
| Electrical Outlet Problem | 5/24/2008 |
Q: I can not get a plug pulled out from an outlet. It is an outlet outside that my pool pump is ... A: Jen, It is possible that the prongs have fused themselves to the inside of the outlet, or they have ...
|
| "Strange" Electical problems in my mobile home | 5/23/2008 |
Q: I have the strangest thing going on here in my mobile home. On several occasions within the past ... A: John, it sounds like your problems are all related in some way. This really sounds like you should ...
|
| Tankless Water Heater Wiring | 5/22/2008 |
Q: I just bought an electric tankless water heater. The instructions say to run two separate 8/2 wires ... A: At 200 feet (100 feet each) you are at the limit for 8/2 so you cannot go to 10/2. If anything you ...
|
| cooktop | 5/21/2008 |
Q: I have a three prong 250V outlet for my old cooktop and just bought a new one that came with a four ... A: The NEC is trying to get us away from the old 3 prong system and converted over to the 4 prong ...
|
| Switches & Receptacles | 5/21/2008 |
Q: I am building a room in my son's basement and want to know how many receptacles & switches can I put ... A: Good question. Technically the outlets and lights should be on separate circuits. The number of ...
|
| bathroom fan | 5/20/2008 |
Q: i am trying to install a bathroom fan.The bathroom has two sets of lights operated by one ... A: You need to determine if the power is first going to the switch or to the light. If power is going ...
|
| Low voltage at wall switch | 5/18/2008 |
Q: A wall switch controls a porch light. It had been working. When it quit working i checked the ... A: What do you get hot to neutral from both sides of the switch with the switch in the "ON" position? ...
|
| water pump to definite purpose (relay?) | 5/17/2008 |
Q: I am installing a new Torrium water pump and water storage tank to replace mt 30 gal. bladder tank. ... A: It sounds like they are switching one leg of the 220 volt. Which is okay. It may be that you have ...
|
| water pump to definite purpose (relay?) | 5/17/2008 |
Q: I am installing a new Torrium water pump and water storage tank to replace mt 30 gal. bladder tank. ... A: L1 and L2 are the supply voltage from the source. You should have two hot legs and a ground. The ...
|
| cooktop hookup | 5/15/2008 |
Q: how to wire a new electronic control cooktop with 240vac 4 wire (red, black, white and green) to a ... A: Black, white, and ground (copper) is considered 2-wire with a ground. When used for 220 volt both ...
|
| stove and miro wave hook up | 5/15/2008 |
Q: i had a direct wire 220v to my stove 3 wire white,black,copper. bought a three wire plug hooked ... A: If these are separate appliances you cannot hook them both up to the same breaker. If you have ...
|
| new light switch wiring | 5/11/2008 |
Q: I have a switch that is at a end run and I wanted to add one more switch that would operate a hall ... A: You are switching either the neutral or hot leg for the existing lights and your new switch and ...
|
| inground pool ground | 5/10/2008 |
Q: I recently pulled out a cement slab in front of my pool that had to holes for a handrail in it. When ... A: Call either an electrician in your area or a building inspector right away to get the proper ...
|
| Kitchen/Bathroom remodel and wiring | 5/8/2008 |
Q: My wife and I are currently in the process of remodeling our kitchen. We do not plan on ripping out ... A: This is a good question because it poses a dilemma for many homeowners updating their houses. If ...
|
| GFCI tripping | 5/7/2008 |
Q: I have a GFCI next to my sink. My refrigerator is the only thing connected to it downstream. Small ... A: The first thing I would do is put the refrigerator on it's own 20 amp circuit. It should not be on a ...
|
| Using a European espresso maker from Italy in the USA | 5/7/2008 |
Q: I lived in Italy and purchased an espresso coffee maker and brought it with me to the USA. I got it ... A: Oh sure you can make it safe and pass code. Of course what you have now is really not advisable. ...
|
| 30 AMP OUTLET | 5/6/2008 |
Q: I HAVE A TILE SAW WITH A NORMAL GROUNDED PLUG THAT NEEDS TO RUN ON A 30 AMP BREAKER. I AM GOING TO ... A: You did not say, but I will assume it is 115 volts. If so, 30 amp outlets are pretty common and most ...
|
| Using a European espresso maker from Italy in the USA | 5/6/2008 |
Q: I lived in Italy and purchased an espresso coffee maker and brought it with me to the USA. I got it ... A: 1)I am not familiar enough with the color system of the Italians to answer properly. If I had a ...
|
| convert one three wire circuit to two circuits | 5/5/2008 |
Q: At present, two fixtures on one switch are in parallel; so a three wire cable connects the two ... A: If you have three wire running from the switch to each fixture you can do this. Take the hot wire ...
|
| dishwasher that may have caused an electrical problem | 5/3/2008 |
Q: A wooden spoon dropped onto the heating element of our dishwasher while it was running. This caused ... A: Mick, Some dishwashers are on their own breakers, and just because a breaker appears to be on does ...
|
| 3 way switches | 5/2/2008 |
Q: I'm installing some new lighting in a house and one of the dimmer switches burned out on me. I was ... A: The original switch has a "hot" leg coming to it and a "hot" leg leaving to feed the light. It is ...
|
| gas to dual fuel range replacement | 5/2/2008 |
Q: I am replacing a gas only slide-in range with a dual fuel one. The only wiring present now is a 40' ... A: John, Even though the bigger gauge wire is more expensive you are smart to be thinking ahead in case ...
|
| 3 way switches | 5/1/2008 |
Q: I'm installing some new lighting in a house and one of the dimmer switches burned out on me. I was ... A: If the original switch had two wires (not including the ground) then it was not a 3-way switch. If ...
|
| 3-wire confusion | 4/29/2008 |
Q: I'm finishing my basement and can't seem to successfully add 2 lights to the existing lighting ... A: It sounds like the black wire is being ran as "hot" all the way from the breaker to your switch. ...
|
| jenn air cooktop | 4/29/2008 |
Q: On my new jenn air cooktop stove, i am having trouble getting the grill warm enough to grill. We ... A: Are you sure it is 3-phase? 3-phase is mostly found in commercial buildings. 208 volts is at the ...
|
| a/c circuit breaker hookup unusual question | 4/28/2008 |
Q: Is this correct? A/C unit calls for a 50 amp breaker. Wire is a size 8 (3 wires and a ground inside ... A: You need to install a 50amp double pole breaker. You need 6 gauge for a 50 amp breaker. Two single ...
|
| 220 volt to 115 volt | 4/25/2008 |
Q: I have a 220 single pole outlet (nema 6-15 plug) that I would like to convert to a 115 volt ... A: Yes, it should be easy. You should have two hots and one ground. You will keep one hot by keeping ...
|
| Installing a Celling fan to a Switch Outlet | 4/24/2008 |
Q: I have a switch that is connected to an outlet in my bedroom. I want to add a celling fan to this ... A: Without drywall work your best bet is Wire Channel or Wiremold. It is channel that goes on the ...
|
| Outlet distance | 4/22/2008 |
Q: We are trying to finish the basement in our house and I was wondering what the distance the outlets ... A: If a wall is 2ft or more it needs an outlet. From the beginning of a wall the first outlet must be ...
|
| Converting a 110 outlet to 240 | 4/21/2008 |
Q: I'm purchasing a new washer/dryer that operate at 240V / 20amp. I've got an existing dedicated ... A: Good question. Usually a washing machine does not fall into the continuous load category, however ...
|
| A/C Start assist kit | 4/21/2008 |
Q: I need a little help here. I have been an a/c mechanic for about 25 years, but have forgotten how to ... A: I am wondering why you are not going with the "Kick-Start" or "Hard-Start" kit? Those are wonderful. ...
|
| halogen lighting problems | 4/20/2008 |
Q: I have a series of 3 halorgen pendants hanging in a series in my kitchen. Yesterday, one light went ... A: If they are truly in series then they are wired wrong. However, I suspect you mean that they are all ...
|
| Install pump start relay | 4/19/2008 |
Q: How do I install a pump start relay? I have a 240v irrigation well pump with 3 wires coming into the ... A: You should place the start relay as close to the pump as possible. If there is no box you can ...
|
| electric space heaters | 4/19/2008 |
Q: How many 1000 watt in-wall or baseboard heaters can be safely wired on (for example) a 20amp 120 ... A: A 240 volt load that does not require 110 volts only needs the black and white plus ground. ...
|
| electric space heaters | 4/18/2008 |
Q: How many 1000 watt in-wall or baseboard heaters can be safely wired on (for example) a 20amp 120 ... A: One on the 120volt circuit and Three on the 240 volt circuit. These would be considered "continuous ...
|
| Motion sensor with multiple lights | 4/17/2008 |
Q: I have a building that I would like the lights to come on when someone comes in the door and then ... A: If you were happy with the system but it draws too much power for the sensor I would suggest adding ...
|
| Water Wire HOT | 4/17/2008 |
Q: The wire to my water heater gets extremely hot (too hot to hold) when it is in heating mode. ... A: My first thought is why are you holding a wire to your water heater? Second thought is what gauge is ...
|
| Second Meter Base | 4/14/2008 |
Q: I have a small metal working business in my home and feel that it uses a good portion of the total ... A: If your shop is separate from the home they should allow this. But I am sure you can see their ...
|
| Sub panel fusing | 4/13/2008 |
Q: I'm planning to install a sub panel to feed a fridge, kitchen plugs, and a dishwasher. Based on ... A: The first thing you need to do is make sure your main panel can support the extra load you are ...
|
| Split Circuit with shared neutral and ground | 4/13/2008 |
Q: Due to some issues with the wiring in my house I have found I am mapping the whole house and ... A: Yes it is allowed, if you mean having two branch circuits sharing a neutral. Yes, you can. It is ...
|
| Wiring a Ceiling Fan w/ dimmer switch and motor control on the wall | 4/12/2008 |
Q: There are similar answers to this question, but I think I have a unique problem here. I want to ... A: The best way to do this is to run another cable from the fan to the switch. Remove the existing ...
|
| please help | 4/11/2008 |
Q: We just moved into a new place. When we attempted to plug a light into an outlet here, there was a ... A: Forget saving your landlord the cost of an electrician and save yourself a lot of trouble by calling ...
|
| Running out of ideas | 4/11/2008 |
Q: I have checked our panel box,switch and outlet power and light bulbs and one trip to the attic. My ... A: Sounds like a perfect candidate for a tripped gfci outlet or breaker. If it is an outlet it will ...
|
| GFI Keep Popping | 4/9/2008 |
Q: Ok, so we bought a refigerator (used) on Craigslist a couple weeks ago. Previous owner said it was ... A: The first thing to do is not plug it into a GFCI protected outlet, ever. Refrigerators, and other ...
|
| home wiring | 4/8/2008 |
Q: last week lightning struck near my house and shut the power off. The power came back on quickly ... A: You should see if there is a gfci outlet controlling those outlets, it may be tripped. Plus, you ...
|
| pendant light | 4/8/2008 |
Q: I just ordered two pendant lights (hanging from the ceiling) and found out they are plug-in. Do you ... A: You have a ceiling cover that the wires fit through and if it is the proper ones for the new lights ...
|
| conversion of power | 4/7/2008 |
Q: I've ran the 220 line and set up the recepticals and had them checked by my local electrician for ... A: You need to look at the nameplate, which I am assuming you have not because you are guessing at the ...
|
| Dryer sparked when plugged in | 4/7/2008 |
Q: I have a maytag electrical clothes dryer that is about 9 years old. It was making a loud noise, my ... A: Lani, I believe the lint trap is in the front so I am concerned when you say he took off the back ...
|
| flickering lights, popping noises, | 4/6/2008 |
Q: I truly hope you can help me! My wife and I have an older home with a 100 amp service. Last night, ... A: The loose neutral certainly could of caused what you described. It is possible that the utility tech ...
|
| conversion of power | 4/6/2008 |
Q: I've ran the 220 line and set up the recepticals and had them checked by my local electrician for ... A: The frequency of a load is only important to certian devices. For instance, an incandescent light ...
|
| flickering lights, popping noises, | 4/5/2008 |
Q: I truly hope you can help me! My wife and I have an older home with a 100 amp service. Last night, ... A: A bad (loose, corroded, etc) main neutral at the panel is connected with every circuit and can cause ...
|
| flickering lights, popping noises, "hot electric" smell | 4/5/2008 |
Q: I truly hope you can help me! My wife and I have an older home with a 100 amp service. Last night, ... A: Mike, This definitely needs to be checked out by a qualified electrician. Is PP & L the utility ...
|
| Comination switch recptacle | 4/2/2008 |
Q: Currently in a 2 gang box I have the garbage disposal switch and a regular duplex receptacle each on ... A: Are you just adding an outlet? In other words, you still have the duplex and now you have a ...
|
| New Circuit | 4/1/2008 |
Q: Mr. Hughes I am adding a 15 amp breaker to my box. It will run about 25-40 feet to the circuit. The ... A: Justin, These are all good questions and I am glad you asked before doing the work. Your outlets ...
|
| My light will not turn off / even without the switch | 4/1/2008 |
Q: Stupid of me... I changed a fixture and during my re-wiring, the light's GROUND cable hit the live ... A: Allan, We need to retrace a bit first. How many wires are in the light fixture box? It is possible ...
|
| Current With Circuit Breaker Off | 3/31/2008 |
Q: Is it possible for a circuit to retain or carry a residual or parasitic charge even when the ... A: Gary, please do not use an aluminum ladder to do electrical work, instead switch to a fiberglass ...
|
| Lighting fixture | 3/31/2008 |
Q: "My new light fixture has clear wire. I have read conflicting - opposite- information on the web ... A: Technically it does matter for safety's sake. However, because it is AC and not DC it will work with ...
|
| 220 plug for hook up of a dryer | 3/30/2008 |
Q: in my kitchen i had a stove they removed the stove we want a dryer there but the 220 wire that was ... A: You will need a voltmeter to check which two are the "hot" legs and which one is the neutral. The ...
|
| Arching | 3/30/2008 |
Q: My daughter just moved into a single family home. When pluggingin the gas stove circuits in house ... A: You have done the right thing by calling out a professional electrician. This sounds like a ...
|
| double pole gfci circuit | 3/29/2008 |
Q: I hope that you can help me with this question. I pulled 4 #12 thhn wires to my bathroom, with the ... A: I do not know why you want two independent outlets. The only reason I can think of is that you are ...
|
| how to size a panel | 3/28/2008 |
Q: i have a friend that wants to change out his panel from a 100 amp servise to a 200 amp servise but i ... A: 100 amp panel use to be the standard, but with all the new appliances and loads a lot of people are ...
|
| Pendant lighting | 3/25/2008 |
Q: Is there a rule of thumb to hang pendant lights.I feel the previous owner hung them in the wrong ... A: They are generally hung in the center over the counter to light up the countertop. Generally they ...
|
| Thermostat duel fuel | 3/23/2008 |
Q: I have conventional heating and a heat pump and I wanted to put a programmable thermostat in. I ... A: Honeywell makes good products. What you need is a heatpump t-stat. Keep a record of what you just ...
|
| Amperage Question | 3/22/2008 |
Q: I was wondering if you could assist. I originall asked Rick Meill a question about roughing in the ... A: Lets go back to the start. According to the NEC, your bathroom outlets cannot be shared with any ...
|
| adding single pole switch for under cabinet light | 3/20/2008 |
Q: I am adding hard-wired under-cabinet light fixtures in my kitchen. I want to use a single-pole ... A: Justin, You will need to add what we call a "pig tail" to one of the black wires and one of the ...
|
| cook top replacement | 3/19/2008 |
Q: I replaced a cook top in my kitchen. The old wiring was standard 12 2 110v, the new cook top ic 220. ... A: Are you replacing a gas cooktop with an electric cooktop? You can use the existing circuit as long ...
|
| Wire Warm to the Touch | 3/18/2008 |
Q: Greg, Is there any reason one lone wire should be warm to the touch when all other wires coming from ... A: Most likely it is either drawing more wattage, or it runs more continous than the others. There is ...
|
| wiring question | 3/17/2008 |
Q: I have little wiring knowledge so bear with me, in a bathroom I am trying to switch a ... A: Aaron, Thanks for the picture it helped me see what you were saying. Actually this has been wired ...
|
| new light fixture | 3/17/2008 |
Q: i have just replaced one light fixture in a hallway with another and rewired the new fixture the ... A: There are about 12 different ways to wire a 4-way switch circuit. What I need to know is how the ...
|
| Lights Dimming, then brightenning - Really worried! | 3/16/2008 |
Q: I live in a rental apartment, that is likely 50+ yrs old now (not sure exactly). I have put a call ... A: Your local utility company may be of some assistance, so you might give them a call. I do not know ...
|
| Tap an existing electrical wire | 3/14/2008 |
Q: I'm installing a steam shower. The steam generator requires a 110V/30A power supply. Nearby in the ... A: Norman, I have never used those on anything more than 24 volts, and I probably would not. But you ...
|
| Bathroom H-F-L-NL rough in question. | 3/14/2008 |
Q: Can you give me some guidance on roughing in my bathroom? I bought my house with an unfinished ... A: BC, If you are in the United States, this is not up to code as I understand what you are ...
|
| New wiring | 3/13/2008 |
Q: I had a contractor install a new Jacuzzi tub which required 220. The existing location had 110 ... A: There are several issues to this. To answer you first question; This is how 220 volts is made when ...
|
| Lights Out | 3/11/2008 |
Q: My boyfriend was painting the kitchen and had all the outlets unscrewed from the wall he hit the ... A: The best way to diagnose is with a voltmeter. If you do not feel "qualified" enough to stick a meter ...
|
| No power to rooms. | 3/11/2008 |
Q: I'm having a problem with no power getting to neither my sister's room, nor the bathroom (they're ... A: Two things to check. First see if there is a gfci outlet in the bathroom. There should be one and ...
|
| wiring to a triple switch | 3/10/2008 |
Q: Please could you help. I am trying to connect 2 individual kitchen lights and an outside light to a ... A: The back of your triple switch should have a common on one side and three terminals on the other ...
|
| clicking sound in wall | 3/8/2008 |
Q: At night while lying in bed I hear a clicking sound coming from the wall. It appears to be coming ... A: You could try turning of the breaker to that outlet one night and see if it goes away. More likely ...
|
| light switch/outlet | 3/7/2008 |
Q: I have a light switch (for light above kitchen sink) and an outlet in the same receptacle box. I ... A: My best guess is that one of the wires came loose in a wire nut (cap). With that many wires in one ...
|
| WIRING NOT SHUTTING OFF | 3/6/2008 |
Q: I remodeling my basement. i placed 7 can lights in the ceiling and would like to have these on a ... A: Mike, Unless these are high wattage heat lamp bulbs 30 amps is too much. They should be on a 15 amp ...
|
| Jacuzzi bathtub wire. | 3/5/2008 |
Q: I am installing a Jacuzzi bathtub which requires a 120 VAC, 15 AMP, 60 Hz dedicated GFCI protected ... A: Dan, I would recommend running pvc conduit on the outside of the house, and installing a gfci ...
|
| Installing new light fixture | 3/4/2008 |
Q: I had our handyman Tyler come to our 10-year-old house (purchased by us in the fall of 2007) to do ... A: You are correct, the power was ran to the fixture and then the hot leg was sent down to the switch ...
|
| Light fixture | 3/3/2008 |
Q: I am trying to install a light fixture with a 3 way switch, but I am not sure where the wire from ... A: Tony, It sounds like power is coming in one switch and the other switch is being fed through your ...
|
| faulty breaker | 3/1/2008 |
Q: I have an old breaker I'm trying to replace the only writing on it is CB SWP it is a single pole 15 ... A: Yes take it with you and it only matters if the breaker itself is gfci. It would probably be better ...
|
| Ground Rods | 3/1/2008 |
Q: Have upgraded old service from 60 amp to 100 with new disconnect and panel box.How many ground rods ... A: You need one ground rod and you will need to ground the water pipes. Check with local codes to see ...
|
| range cord | 2/29/2008 |
Q: we have a 40-amp range, and can only find 50-amp cords at Home Depot. is it okay to attach a 50-amp ... A: Will it work? Yes. Technically, the wire size should match the outlet rating. Will it cause a ...
|
| Hot wire, very hot. | 2/29/2008 |
Q: I bought a new over the range micro/convection oven with a 110v plug. The previous fan/light hood ... A: Those are not meant to be hardwired, hence the cord. So that is the first thing gone wrong. Next, ...
|
| no power to GFI outtlet in bathroom | 2/26/2008 |
Q: the GFI went out and we replaced it but there is still no power to the outlet. The circuit breaker ... A: Your follow question needs to be more specific. Do you have power at the wire on your circuit ...
|
| no power to GFI outtlet in bathroom | 2/25/2008 |
Q: the GFI went out and we replaced it but there is still no power to the outlet. The circuit breaker ... A: Pull the outlet out of the wall and check with a voltmeter across the two wires. If you have power ...
|
| Failing miserably at installing a light fixture | 2/25/2008 |
Q: I have done a lot of research and I'm not too goo ith terminology but I'll try my best here. I spent ... A: Mark, It sounds like you need to connect to red and white at the light fixture. Here is a quick ...
|
| Wiring in our home | 2/23/2008 |
Q: We have a new construction and have noticed that whenever I run the vacuum the lights dim. Is that ... A: Yes, it could be an indication that something is not correct. The outlets should not be on the same ...
|
| 100A subpanel | 2/22/2008 |
Q: We are finishing our basement and one electricians quote includes installing a 100A subpanel, the ... A: Patti, A subpanel is used when you either need more room for breakers than the box has, or you need ...
|
| multiple fixtures | 2/1/2008 |
Q: we are stuck!! we got two 3way switches with 3 light fixtures between them...HOW DO WE WIRE IT WITH ... A: This has a level of difficulty to it. 3-wire is black, red, white and ground. 2-wire is black, ...
|
| Range Wiring | 2/1/2008 |
Q: I moved into a home built in 1981. The range area in the kitchen had no receptacle. It had a armor ... A: You mentioned that you have 4 wires. Two hots, a neutral, and a ground. You said the ground and ...
|
| Circuit problem | 1/31/2008 |
Q: I've been using a lot of electricity on one particular circuit (my room). I was using the tv, ... A: Your question is not aimed at the source problem and that is you are overloading your circuit. ...
|
| Range Wiring | 1/31/2008 |
Q: I moved into a home built in 1981. The range area in the kitchen had no receptacle. It had a armor ... A: If you want to bring it up to the newest code you will need to install a 4 prong plug and a 4 prong ...
|
| InGround Pool wiring | 1/29/2008 |
Q: I am in the process of running a feed line to a pump house located near the pool. I have read ... A: A portable spa has a breaker in the main panel and then a gfci breaker in the disconnect located ...
|
| Tracklights burning out. | 1/29/2008 |
Q: i'm a new j-man electrician in canada, so im doing some trouble shooting for my sisters place. but ... A: Tracklights are very specific in what can be used and the allowed wattage. Often people put in a ...
|
| Short circuit in a Jenn Air Range | 1/28/2008 |
Q: Hughes, I have read your answer on another Jenn-Air range, 4 to 3 wires conversion, but, while very ... A: From your explanation it does not appear that you did anything wrong. It sounds like the 110 volt ...
|
| Arc Fault Circuit Breakers | 1/27/2008 |
Q: We are in the final phases of purchasing a house built in 1940. During the home inspection, our ... A: With the wiring is in this condition it sounds like a whole house rewire is in the near future. If ...
|
| Outlet/light combo | 1/27/2008 |
Q: I built a room in my basement and I want to wire lights in it. I would like to use the same power ... A: Be careful to not overload any of the circuits. Find out what is on the circuit you would like to ...
|
| electrical panel | 1/26/2008 |
Q: I have a 3 panels with 3 separate 50 amp services coming into my RV home. 1 for the heat pump, 1 ... A: If you run the washer and dryer at the same time you will be pulling almost 30 amps. The new water ...
|
| TRipped Circuit Breaker, no devices plugged in, no wire ends touching | 1/24/2008 |
Q: In the process of remodelling my kitchen, I removed the cabinets from the walls. To get one cabinet ... A: First turn the breaker all the way to the "off" position and then try turning it to the on position. ...
|
| 240v hookup | 1/23/2008 |
Q: I had a professional rewire my new home, and install a laundry in the basement. I decided to make a ... A: The two things I suggest you do is to buy a voltage tester and remove the wires from the circuit ...
|
| Dimmer Switch 2 black wires and One Green | 1/23/2008 |
Q: I bought this a few years ago, and never got it installed and am without packaging (surprise!) I ... A: The markings indicate the type of wire used. Your old switch should have two wires connected to it ...
|
| Adding an Outlet for Plasma TV | 1/22/2008 |
Q: "I have an electrical outlet that I am trying to add a new outlet to use for a 50" plasma ... A: Are you installing the outlet in the upper half of the wall? Since you already have a refrigerator ...
|
| Breaker size for small appliance | 1/21/2008 |
Q: I was planning to install a small 500watt base board heater (240V) I have a 240V line on a 50amp ... A: Your base board heater does not meet the requirements to be fed directly from the range. Your ...
|
| SUB PANEL | 1/21/2008 |
Q: GREG THANKS FOR TAKING TIME TO HELP. I HAVE A REMODEL OF A KITCHEN. WE HAVE REMOVED THE OVEN STOVE ... A: Can you replace two of the 15 or 20 amp breakers with a "twin" breaker? It is a thin version and has ...
|
| Ceiling Fan wiring | 1/14/2008 |
Q: I am replacing a ceiling fan/light combo unit and didn't pay close attention to how the original ... A: Take the white wire that is paired with the "hot" wire and connect it with the white wire from the ...
|
| Ceiling Fan wiring | 1/13/2008 |
Q: I am replacing a ceiling fan/light combo unit and didn't pay close attention to how the original ... A: Your best thing to do now is purchase (if you don't own one) a tester. Separate all the wires and ...
|
| 110v apliance on 230V socket | 1/13/2008 |
Q: I am a fellow volunteer at allexperts.com, though of a very distinct area of knowledge: Dentistry. ... A: Looking back I thought the bulb was rated at 125 volts, but I now see that the extender is rated at ...
|
| Garbage disposal wiring | 1/12/2008 |
Q: I have a new garbage disposal with a white and black wire. The old disposal was connected to a ... A: Sometimes the electrician leaves 110 volt at one of the two outlets at the double outlet, and the ...
|
| 26 volts on turned off breaker | 1/10/2008 |
Q: Live on an island, solar/wind house for collecting power inverter used to produce AC, house is wired ... A: Charles, There are several things to look for. Check for voltage coming from your ground rod up ...
|
| possible defective residential electric meter | 1/9/2008 |
Q: We started reading our meter several times a day when our bill became unreasonably high and found ... A: The digital meter will not act like the older type that you could watch spin. There is a product ...
|
| Extension Cords | 1/8/2008 |
Q: You have seen the craze on christmas lights beening set to music.. Well I joined the club. But I do ... A: It is a little late for Christmas but I like the idea. There is wiring that is rated for outdoor ...
|
| warm electrical receptacle / brackish wires | 1/8/2008 |
Q: in our home there are no gfi receptacles. i noticed that the bathroom receptacle is warm when it ... A: The most likely culprit is an overloaded circuit. However, it is possible that the outlet is worn ...
|
| electrical trouble | 1/7/2008 |
Q: I was trying to install a ceiling fan when I touched to wires that apparently didn't go together. ... A: Check to see if the GFCI outlet in your bathroom tripped. It may be in a different bathroom if you ...
|
| WELDER WIRING OUTLET | 1/7/2008 |
Q: the breakers are a double-throw(barred-together) am i to believe the wiring is 10-3 not 12-2 ... A: Eric, I would not assume that the wires are 10 gauge and they would not need to be 3 wire for a ...
|
| rewiring | 1/6/2008 |
Q: My aged parents have been told they probably need their 5-bedroom house rewired. I know this ... A: No need to apologize for the length, it helps me give better advise. Since this is happening to the ...
|
| rewiring | 1/5/2008 |
Q: My aged parents have been told they probably need their 5-bedroom house rewired. I know this ... A: Hmmm, just how long is a piece of string? It sounds like you already know my answer but I will go ...
|
| wiring a heat pump to breaker box | 1/3/2008 |
Q: i recently purchased a heat pump and the electric installing was not included in the install , i ... A: Is this a wall unit, split system, or package unit? You mention two breakers in the furnace, are ...
|
| Lights dim and bright | 1/3/2008 |
Q: House built in 1920's New wiring added 2 yeaars ago with new breaker box. I turned on the washing ... A: It appears to be your whole electrical system that is affected. The voltage needs to be checked at ...
|
| 240 Volt Wall Heater | 1/2/2008 |
Q: Have purchased a 240 V wall heater and already have 240 v. run to the location. The wireing is red, ... A: You can open up the circuit breaker panel and see if the black and red are connected to the double ...
|
| 220 and 110 for Washing Machine and Dryer | 1/1/2008 |
Q: I have a stacking washer and dryer in a closet in a high rise apartment. The closet has a 220 ... A: The 220 volt outlet was intended for a combo unit that requires one 220 volt outlet. The internal ...
|
| conduit | 1/1/2008 |
Q: i need to run a new circuit from my existing panel to a new addition on the opposite side of my ... A: Check local codes you may not need to run the coax and phone line in conduit. If you do, then no, do ...
|
| how to start an Air Conditioning and Heating business | 12/30/2007 |
Q: My father and I are considering starting an Air Conditioning and Heating business in a small local ... A: Drew, you would be better served by contacting local HVAC companies and your local BBB. You might ...
|
| Switch has 60VAC in off position | 12/29/2007 |
Q: I just bought my house 6 months ago, and I'm in the process of redoing one of the bathrooms. Today ... A: It appears that you have reverse polarity somewhere. Meaning that your neutral wire is hot. Take ...
|
| Converting 120/240 circuit to 240 only | 12/29/2007 |
Q: How can I convert a 120/240 circuit with a Nema 14-30 receptacle in my basement to a 240 volt 30 ... A: In a 240/120 volt outlet you will have a black and red hot leg. The white is neutral and green/bare ...
|
| Re: Rewiring a 110 lamp 220 | 12/28/2007 |
Q: We are building a house in Ireland and are looking to bring some lamps from the US. Are we able to ... A: I believe a simple plug adapter will work for you since the load is purely resistive. Check the lamp ...
|
| Installing a ceiling fan | 12/27/2007 |
Q: My husband and I just bought a new ceiling fan for our bedroom. Previously, we had been using a ... A: In residential wiring "red" is never, ever used as ground. There are standards for wiring and those ...
|
| breaker burns and smokes | 12/26/2007 |
Q: I had a new furnace and heat pump installed 12 months ago. everything was working fine until 2 weeks ... A: Quickly get a qualified electrician familiar with mobile homes to check out your electrical system. ...
|
| Oven and Cooktop wiring | 12/25/2007 |
Q: My house was built in the early '80s. We will be installing a new cooktop and built-in oven soon. ... A: It will save you money by not installing an outlet and cord for your built in oven so that is good ...
|
| Gas range | 12/24/2007 |
Q: My contractor installed my gas range (convection oven gas burners); manual says to use 125/250 volts ... A: The manual states that you need 125/250 volts and your contractor said that 110 volts "would ...
|
| thermostate replacement | 12/23/2007 |
Q: I have an old thermostat with 7 wires. I don't know what to do with the "B" wire. can you help? ... A: The best thing to do is trace the "B" wire and find out what it feeds or being fed from. Usually it ...
|
| King Wall heater | 12/23/2007 |
Q: im wanting to install a king wall heater and run it off 220volt,but there is only 110V supplying a ... A: You cannot connect to that light switch or light fixture to feed a heater. You did not mention the ...
|
| Garage Heating Solution | 12/23/2007 |
Q: I just can't figure out what to do and I was hoping you could help. I've installed a 240V heater in ... A: I would install a relay with a 220 volt coil that closes the circuit to the 110 volt fan circuit ...
|
| Main breaker haphazardly trips | 12/23/2007 |
Q: I am having a problem with the main circuit breaker in my apartment. Once in a while, it will break, ... A: It sounds like you need a bigger main breaker, however you can only install one if the supply wire ...
|
| open ground at receptical | 12/22/2007 |
Q: Can you install a GFI receptical in a circuit that has an open ground and be in code? A: Yes. You have to mark the receptacle (on the outside so anyone can see) that it is ungrounded. Most ...
|
| shop wiring | 12/22/2007 |
Q: I recently bought a house with a small work shop. The problem I'm having is the receptacles only ... A: The first problem I notice is that the breaker is over rated for the wire size. That is a code ...
|
| hot water heater | 12/22/2007 |
Q: we have changed the elements and the thermastats on our hot water heater, but still don't have hot ... A: Have you pushed in the "reset" button on overtemp protection? If you feel qualified, measure the ...
|
| Burned up line voltage thermostat | 12/21/2007 |
Q: I had electric baseboard heat in a room addition and the 240 volt line voltage thermostat melted the ... A: The breaker will trip if an overload of current passes through it. From your explanation I am not ...
|
| both my outlet holes are live | 12/21/2007 |
Q: I added a bunch of outlets to my house recently when we were remodeling and we just realized that ... A: How are you testing to see if they are "live"? This would mean that you disconnected a neutral and ...
|
| three cable confusion | 12/19/2007 |
Q: I am trying to move the location of the switch (which was in a very inconvenient spot) in the ... A: Since you did not mark the wires when you removed the switch you will need a voltmeter to be able to ...
|
| Space heater wiring | 12/18/2007 |
Q: We keep tripping the fuse when we use a new space heater. We have tried different outlets.One on a ... A: Your voltage will play a part in how many amps are pulled. But in any case your 15 amp circuit ...
|
| Single Circuit Rewire, PVC Conduit Use | 12/17/2007 |
Q: I have a quick question. I am rewiring a single circuit in my home (one of the last which was ... A: 1. Use the gray PVC found in the electrical department along with the glue that is made especially ...
|
| Outdoor lighting with motion detection | 12/17/2007 |
Q: I want to install outdoor motion sensor light, but also want to control the same light from an ... A: Most outdoor lights with motion sensor have a way to turn them on at the switch without motion ...
|
| Electrical clothes dryer | 12/17/2007 |
Q: I'm renting a house with a hook up for a gas dryer. I own an electrical dryer. i want to hook up my ... A: You have two choices. You either buy a gas dryer, or you get the landlord to run a 220 volt circuit ...
|
| 220v circuits | 12/15/2007 |
Q: When I moved to the US from the UK I brought all my 230V woodworking tools with me - in the hope ... A: Gareth, Actually they are both single phase. Here in America the norm is 120 volts supply and in ...
|
| 200 amp to 400 amp service upgrade? | 12/15/2007 |
Q: I also sent this question to another moderator in this forum but since then noticed that you have ... A: Ken, Adding up the breakers in the panels is really of no value since they are rated above what the ...
|
| Oven wiring | 12/13/2007 |
Q: I am installing a KitchenAid double convection oven. The pigtail has 4 wires, black, white, red and ... A: This would not pass code today. Not all inspectors pay close attention to detail so this could of ...
|
| heater | 12/13/2007 |
Q: if i my heater is not heating and I have a light blinking on and off on my circuit board, what does ... A: It means that your board detected a fault. A certain amount of blinks in a row tells the technician ...
|
| Changing a ceiling fan into 2 flush mount light fixtures | 12/13/2007 |
Q: G., I have a client that needs me to change a ceiling fan into 2 flush mount light fixtures on the ... A: It depends on where you want the lights. If they have to be in an exact location and other than the ...
|
| Changing a ceiling fan into 2 flush mount light fixtures | 12/12/2007 |
Q: G., I have a client that needs me to change a ceiling fan into 2 flush mount light fixtures on the ... A: Flush mount refers to a light that hugs the ceiling. You should be able to simply remove the ...
|
| Electric baseboard heater problems | 12/11/2007 |
Q: I just bought a condominium constructed 20 years ago. There was a 1000 watt 208V baseboard heater ... A: It could be a partially tripped breaker. The best way to check is with a voltage meter. Put the two ...
|
| Battery Preservation | 12/10/2007 |
Q: Since one usually has to buy batteries at a store in packs, how can I store the batteries I don't ... A: Batteries generally do not like extremes (hot or cold). I am assuming we are talking about AAA, AA, ...
|
| wall mounted switch | 12/9/2007 |
Q: A: This is a good question. If you are remodeling a house for little people, or people in wheel chairs ...
|
| light fixture wiring | 12/6/2007 |
Q: i am installing a new light fixture in an old house. the new fixture has a black wire, a white wire ... A: Take the two black wires and connect them to the black wire of your new fixture with a wirenut. Take ...
|
| Having two dryers in one home | 12/4/2007 |
Q: I have two dryers but only one plug. Is there a plug made to run both dryers on the same circuit, ... A: You might get away with it if they are both GAS dryers. But if they are electric, you will not be ...
|
| Furnace Motor Wiring | 12/2/2007 |
Q: I do understand my motor has different speeds, but if I only connect White to white, and Blk to Blk, ... A: Most home owners should not mess with the speed of their furnace blower motor. The speed needs to be ...
|
| lights dimming when other loads start | 12/2/2007 |
Q: We are experiencing a problem with lights dimming in our home. When other loads such as microwave, ... A: Your symptoms all point to either low voltage, too many loads on one circuit, or a loose neutral or ...
|
| outdoor electrical outlet | 12/2/2007 |
Q: I am trying to plug up my Christmas lights and they won't work from any of the outlets on the ... A: They should be fed from a GFCI outlet or GFCI breaker. If you look in your breaker panel and find a ...
|
| Follow up to question I asked of Will Babbit | 12/1/2007 |
Q: I assume you have access to my question but basically, I have an 3hp, 11 amp, single phase, 230V ... A: Jeff, I do not have access to your original question. Is this a dedicated line to your planer? ...
|
| 20 amp outlet | 12/1/2007 |
Q: Sir: The A/C I'd like to install has a 20 amp plug. Is it possible to replace the existing outlet to ... A: If you are trying to plug it into a 15 amp circuit than you need to run a new circuit for the A/C or ...
|
| Adding a sub-panel | 11/30/2007 |
Q: Greg, I am adding about 500 sf to my house and will be adding a sub-panel for the new circuits. I ... A: To do it correctly a "Load Calculation" needs to be performed on your existing circuits with the ...
|
| Wiring Question | 11/29/2007 |
Q: Greg, I recently bought a new house and had a quick question regarding the wiring of the Electric ... A: Martin, First find out what the requirements are for the oven. If the oven requires a 30 amp ...
|
| grounding... | 11/28/2007 |
Q: We have a 2 1/2 yr old modular on a full concrete basement. Ever since, we had a water issue, with ... A: On top of your tank you will find a large nut. Under that nut lies the anode. You will need to turn ...
|
| grounding... | 11/27/2007 |
Q: We have a 2 1/2 yr old modular on a full concrete basement. Ever since, we had a water issue, with ... A: Mike, You did the right things by grounding the pipes and installing the correct connectors from ...
|
| wiring pot lights | 11/27/2007 |
Q: I`m was wondering about wiring 6 pot-lights in a 20-10 rec room. its a drop ceiling, the ? is when ... A: Your first light should have two wires coming in (hot and neutral). Connect these to the wires of ...
|
| Hot to touch Ceiling light fixture | 11/25/2007 |
Q: I have a flush ceiling light fixture in kitchen. It smells hot and is hot to touch.I was up in crawl ... A: When you say "flush" are you referring to a "recessed" light fixture? If so, there are basically ...
|
| change a circuit breaker | 11/25/2007 |
Q: I have a circuit breaker that has gone bad. A little bit of smoke comes out of it when it is on so I ... A: Most breakers place the model number on the side of the breaker so you cannot read it until you ...
|
| Outdoor light on 20 amp circuit | 11/24/2007 |
Q: I goofed when I rewired my home. I wasn't thinking and tapped of a junction box for lighting in one ... A: Putting a j-box concealed in the wall is against code. Running the wire diagonally in the wall is ...
|
| Aux Electrical Panel | 11/23/2007 |
Q: I want to install an aux electrical panel in my basement for new basement shop power, game room ... A: You do need a 100 amp breaker in the main panel to feed the subpanel, and you need a separate ground ...
|
| Outdoor light on 20 amp circuit | 11/22/2007 |
Q: I goofed when I rewired my home. I wasn't thinking and tapped of a junction box for lighting in one ... A: Is it unsafe? You need to wire it correctly and protect it from weather. The difference between a ...
|
| Wall Oven installation | 11/21/2007 |
Q: We have purchased a new frigidaire wall oven, which has the standard 4 wires ( a red, a black, ... A: I am not sure where you live and I do not know local codes. However, if it were me with this set up ...
|
| Thermostat | 11/19/2007 |
Q: If my digital programmable thermostat is showing the correct room temp and date/time but won't turn ... A: The problem with jumping at the furnace is that you have not ruled out a broken wire between the ...
|
| Installing a dimmer switch | 11/19/2007 |
Q: Hey Greg, This might be a simple question but I have to ask, novice here. I am installing a dimmer ... A: Yes, you have a 4-way switch. (I deleted my remarks about advise given from "shelf stockers" about ...
|
| Thermostat | 11/18/2007 |
Q: If my digital programmable thermostat is showing the correct room temp and date/time but won't turn ... A: Most digital t-stats show they are calling for heat (usually in the form of an icon), this is what ...
|
| New Home electrical Panel | 11/18/2007 |
Q: I am building a new home approximately 2500sf main floor (incl garages) 2000 top floor and 2000sf ... A: A lot will depend on whether you use gas or electric for your big loads (heater, water heater, oven, ...
|
| Installing a dimmer switch | 11/18/2007 |
Q: Hey Greg, This might be a simple question but I have to ask, novice here. I am installing a dimmer ... A: Does the original switch have four posts (not poles) or two? If it has two, and the two red ones ...
|
| New light fixtures are tripping the breakers | 11/17/2007 |
Q: I am replacing two wall sconces with new ones. The old fixture was a type A the new ones require ... A: The Type of bulb refers to the shape of the bulb. You should have more info than Type A, or B, or C. ...
|
| thermostat replacement | 11/16/2007 |
Q: Good evening. I wish to replace my 19 year old Lennox heat pump thermostat with a Honeywell ... A: Rick, Lennox did their own thing when it came to wire color and naming standards. So their units do ...
|
| Electrical Outlet problem | 11/16/2007 |
Q: I have an electrical outlet in the kitchen that the toaster will not work in. I can plug in a lamp, ... A: It sounds like the plug from the toaster is not making good contact with the prongs in the outlet. ...
|
| residential light switch | 11/15/2007 |
Q: We have lived in our 1960's built 3 bedroom story and a half for 20 years. About 10 years ago I ... A: What type of light bulb are you using? If it is incandescent, you may need to replace the switch. ...
|
| circuit problem | 11/14/2007 |
Q: I was running a tale saw when the circuit went dead. The beaker did not trip, though I have since ... A: If this is A/C current you do not have a positive and a negative. You have what we call a "hot" and ...
|
| Breaker panel | 11/14/2007 |
Q: I am buying a NEW house in Texas. Is there any particular reason that the circuit breaker panel for ... A: In warmer/milder climates it is not unusual to have your main panel mounted outside. Where I live I ...
|
| Main Panel | 11/13/2007 |
Q: I have a 200A main service panel (installed & inspected new in 1981). It is Sylvania panel with ... A: I found this in the question pool and thought I would address it because it is a very, very popular ...
|
| Ceiling fan question | 11/13/2007 |
Q: I purchased a new home and recently installed a hunter ceiling fan to a pre-wired junction box. ... A: Doug, You had two wires from the two switches (one for the light, and one for the fan) correct? ...
|
| Electrical Outlet issues | 11/11/2007 |
Q: Recently had some electrical work done to the house. All in all, went well, but I have one ... A: Douglas, a good way to find out if you hired a great electrician is to call them back out on ...
|
| fusebox | 11/11/2007 |
Q: last night the plug sockets in my house all stopped working. The overhead lights continued to work. ... A: You either have a circuit breaker that no longer works correctly, or you have a short in that ...
|
| A 100 year old house.. to buy or not to buy? | 11/10/2007 |
Q: My husband and I are facing a relocation to the Chicago area in a few months and are toying with the ... A: Chicago has some great pocket areas and I love the city (to visit that is). I lived just outside ...
|
| sub-panel install | 11/10/2007 |
Q: I'm renovating a 500 sg' room above the garage. There is 200 amp service in the main house with a ... A: The 10 gauge will not pass. It would be for a 30 amp breaker only. Instead of adding up the ...
|
| replacing an old wall oven and cook top with a 1 piece combo | 11/8/2007 |
Q: I am in a 40 - 45 year old house. The breaker box is the infamous federal "no blow" pacific. I have ... A: Not knowing exactly all that is involved I cannot really comment on the estimate. I do not have the ...
|
| electrical | 11/5/2007 |
Q: is it normal for lights to dim when i start the vaccum cleaner in the same room? A: It is not suppose to be normal, however it is not uncommon. Many homes have the receptacles and ...
|
| Outlet replacement - 4black wires and 1 shite | 11/3/2007 |
Q: I've replaced almost all of our outlets, some have 2blk/2wht with 1 ground, some are 1blk/1wht. Now ... A: No need for another outlet. Take two black wire and pig tail it (wire nut) with a small piece of ...
|
| Electric Cooktop wiring. | 11/2/2007 |
Q: I just swapped out A Jenn-Air Electric Cooktop for a New Kitchen-Aid Unit. My Power supply is 3 wire ... A: Wires from breaker panel to the cooktop: Black should be one power leg from breaker. Red should be ...
|
| Honeywell visionPRO th8000 thermostat | 11/1/2007 |
Q: I have the above mentioned Thermostat installed recently with a new heat pump and works in ... A: It sounds like your back up heat is not coming on. The sequence for heat is usually, heat pump only ...
|
| Short circuit | 10/31/2007 |
Q: I have a portable Dimplex air cond. and I'm pretty sure there is a short somewhere because whenever ... A: Frank, The small pump is not weird for a portable A/C. It is used to help eliminate the condensate ...
|
| Grounding... | 10/30/2007 |
Q: Our house is a 2 1/2 yr old modular on a full basement in Central New York. Ever since moving in, we ... A: Mike, I am sorry you had so many problems and expenses. Did anyone check your water heater to make ...
|
| furnace electrical componets | 10/29/2007 |
Q: My circulation pump on my boiler keeps running even when the zones are not calling , what part is ... A: It depends on how you have it wired. Usually the t-stat calls for the circ pump. If you have ...
|
| breaker box wiring | 10/29/2007 |
Q: I have installed a breaker box in my wife’s green house. The main breaker box has a 30 amp ... A: From the 30 amp breaker from the main box what size wire did you run to the subpanel in the green ...
|
| What is this? | 10/28/2007 |
Q: We just moved into a new house and were wondering if you could tell us what this is and what is used ... A: My first guess is that it is an outlet from another country than the United States. It sort of looks ...
|
| Electrical box | 10/26/2007 |
Q: I am in the process of buying a home. I briefly looked at the breaker box. How do I know what type ... A: The two 100 amp breakers means that you have a 100 amp service. If you want a larger service you ...
|
| arc Fault breakers | 10/25/2007 |
Q: I am going to upgrade my service to 200A with a new panel and the question is what do you think ... A: Not that I know of. One is looking for arching and one is looking for leakage to ground. I have ...
|
| Switch confusion | 10/24/2007 |
Q: Hughes, I'm hoping you can help me. I bought this house about a yr ago and finally found a ... A: Sorry you are having so much trouble. It sounds like maybe the light use to be a pull chain and ...
|
| New light fixture | 10/23/2007 |
Q: I have just installed a new chandelier over our dining room table. Everything is working, but I was ... A: Lewis, This is a good question. The answer is; because this is AC current the light will still ...
|
| sauna circuit | 10/22/2007 |
Q: I have a 6k sauna heater on a 240v breaker. I changed to a gfci breaker. The breaker trips when the ... A: Jim, Where I live, the sauna company will not deliver the new sauna until an approved GFCI ...
|
| converting a 3 way switch to an outlet? | 10/22/2007 |
Q: I have a 3 way switch that controls a light in my den. I would like to use one switch to control ... A: Normally one switch has both a hot and neutral, and the other switch does not. (I say normally ...
|
| ROMEX | 10/21/2007 |
Q: MY WIFE AND I BOUGHT A HOME A ARE DOING A FULL REHAB I HAVE TO "REWIRE" THE HOUSE HAVE THE ... A: Nathan, This is a big job and many codes are involved. I strongly suggest you get a qualified ...
|
| Hooking up a telephone jack | 10/20/2007 |
Q: We had a phone wire installed a few years ago and now have decided to hook it up. The phone jack ... A: Be careful, because if someone calls you while you are holding the bare wires you will get shocked. ...
|
| wires | 10/20/2007 |
Q: my q is i just putting in a new cooktop and the new on only has the black com adn the red hot but ... A: Glen, Most cooktops have three wires. Black, Red, ground or Black, White, ground The reason is ...
|
| 50 HZ compared to 60 Hz. | 10/19/2007 |
Q: I have a piano from England and is wired for 220, 50Hz I can supplie 220 but only 60Hz. Will a ... A: It should state on your piano near the model number. It would look something like this: v 220 ...
|
| arc Fault breakers | 10/19/2007 |
Q: I am going to upgrade my service to 200A with a new panel and the question is what do you think ... A: There has been some complaints about false trips from devices used in other rooms than the bedrooms. ...
|
| A/C Disconnect | 10/18/2007 |
Q: I read a question about wiring an A/C disconnect. I have a similar problem. I have run a 10-3 wire ... A: You should have four connections, two for "Line" and two for "Load", and one ground lug. Your A/C ...
|
| New electric heater | 10/17/2007 |
Q: I purchased a new 4000 watt 240V portable electric heater. I have an existing run of 100' 10/3 with ... A: Sorry John, I found your question in the question pool and I am sorry I didn't find it faster. I ...
|
| intermatic little black box | 10/16/2007 |
Q: Brand new. Installed and worked perfectly for about 6 weeks. Suddenly stopped working. Manual over ... A: Intermatic makes many types of timers so I am not sure which one we are talking about here. But, as ...
|
| megger testing | 10/15/2007 |
Q: I was remodeling an older home. A friend (electrician) helped me to rrewire the home. I didn't ... A: Ah, the old Megger Test. To be honest I have not needed to use a Megger since I left the Navy. As an ...
|
| New electric heater | 10/14/2007 |
Q: I purchased a new 4000 watt 240V portable electric heater. I have an existing run of 100' 10/3 with ... A: No this is against code and you will overload the circuit and possibly create a dangerous situation. ...
|
| 2 wire 220v issue | 10/14/2007 |
Q: Don, I have an old home in the mountains with no grounding. My water heater was hooked up with a 2 ... A: You should not use the ground wire to make up the neutral to your dryer, if that is what you are ...
|
| 3-prong dryer to 4-prong outlet | 10/14/2007 |
Q: I was helping a friend install an old model Frigidaire washer/dryer combo stack in her new ... A: Erik, I have not heard of a convertor. But switching to a 4 prong plug is not hard. Instead of ...
|
| 220 volt: 3 wire plug, 4 wire outlet | 10/13/2007 |
Q: On a temporary basis, I want to us a 220 welder in my garage that has a three prong plug by making ... A: The four prong dryer outlet has the ground and neutral separated. Your dryer needs a neutral because ...
|
| wall outlet | 10/11/2007 |
Q: outlet test for continuity, but still does not work with appliances, I have changed the outlet, 2 ... A: Ron, I can remember the first time I ran across a microwave that would not work but seemed like it ...
|
| Light sensors | 10/11/2007 |
Q: Is there such a thing as a combination motion sensor and timer light fixture or add on device? The ... A: Ted, This is what I would do; There are switches that have motion detectors built in, so I would ...
|
| Sump pump & refrigerator on 15 amp circuit | 10/11/2007 |
Q: I recently installed a standby generator. I have a 2nd backup sump pump on a 15 amp circuit and a ... A: Mike, Is your sump pump submersible or is it the pedestal variety? If it is the pedestal variety ...
|
| Building A Job Site Power Distribution Box 220v to 110v | 10/11/2007 |
Q: I have a 150 foot 220v extension cable i would like to use to run power from a 220v temporary power ... A: A couple of reasons you are frying the prongs could be a loose connection between the socket and ...
|
| Mix Lighting & Receptacles On Same Circuit | 10/10/2007 |
Q: I'm getting ready to add a few new electrical circuits to my home. My question has to do with the ... A: As long as it is all 12 gauge then you are fine. In the example of the lone bathroom the whole ...
|
| oven wiring | 10/10/2007 |
Q: I have a built-in oven and, while replacing the lower element had one of the wires slip back into ... A: Rod, Been there done that and it was no fun. Your best bet is to turn off the breaker and pull the ...
|
| Mix Lighting & Receptacles On Same Circuit | 10/10/2007 |
Q: I'm getting ready to add a few new electrical circuits to my home. My question has to do with the ... A: Stuart, I can find one exception right off the top of my head. If you only have one bathroom then ...
|
| Outdoor Outlets and Lighting | 10/9/2007 |
Q: we are putting in a electric gate and lighting about 150' away from the main panel of our home. We ... A: Mike, Good thinking. The first thing you want to do is determine if 220 volts will ever be needed ...
|
| voltage across light fixture w/ switch in off position | 10/9/2007 |
Q: I replaced some ceiling mounted light fixtures for a friend and noticed that with the power switch ... A: Ken, Pretty much most homes have stray voltage at one point or another. Causes range from reversed ...
|
| Fixture keeps shorting out. | 10/9/2007 |
Q: Hey there, I have a switched ceiling box in my basement with a fixture attached. The fixture ... A: These can be very tricky to find the problem. What else is on this circuit? Are you buying bulbs ...
|
| Is neutral wire created at each home? | 10/8/2007 |
Q: This question is more theoretical than practical. I work in the electrical department of a large ... A: If you step outside and look at your line coming from the utility pole you should see 3 wires. Two ...
|
| gfci tripping | 10/8/2007 |
Q: We have a Bay Marie unit outside of our commercial kitchen on a little table. The GFCI receptacle ... A: Angie, Replacing it with a regular outlet may be against code. Check with local code. There is ...
|
| New lights on new breaker, lights are all dim | 10/8/2007 |
Q: I installed a series of 3" can lights to light the perimeter of the main rooms in our house. These ... A: You wired the lights in series but they need to be wired in parallel. You have created a voltage ...
|
| motion sensor wiring | 10/8/2007 |
Q: I am stumped. Trying to wire a motion sensor. the box has black,white, red wires coming in from ... A: Dustin, Some motion sensors come pre-wired so you all have to do is wire black to black and white ...
|
| Pull Chain Removal w/o room for wires | 10/8/2007 |
Q: I live in an older building and of the 20 or so overhead lights in the apartment, 3 have pull ... A: Evan, You have two options; You can install "raceway" type conduit that is exposed or you can ...
|
| leakage voltages? | 10/7/2007 |
Q: I am measuring about 30 volts between the live wire of the 240v mains and the (disconnected) live ... A: Derek, Is this a 240 volt light? Check voltage across the light fixture with the wire disconnected ...
|
| Connecting an American Dryer | 10/7/2007 |
Q: I recently moved to Spain and brought our 220V dryer with us. Can I connect to a European outlet ... A: If your appliance says 50/60 hz and if you can get 110 volts from the 220 volts. Remember, your ...
|
| Hampton Bay remote reciever installation | 10/7/2007 |
Q: I just purchased a Hampton Bay Mediterranian ceiling fan. I was two steps away from finishing ... A: Gamal, They make those darn remotes almost too big to fit up there. What you have to do is get all ...
|
| Neutral Line and voltage | 10/6/2007 |
Q: My question is more on electrical theory. If the neutral line on a 120 volt circuit is the return ... A: Your answer is "voltage drop". If you study electrical theory you will understand how these three ...
|
| EUROPEAN CHANDELIER | 10/6/2007 |
Q: I have a european changelier that I bought from Chez and want to know can it be used in the US. I ... A: If this is a 110-120 volt light than it should work. Since this is ac current all we have to do is ...
|
| service panel limits | 10/6/2007 |
Q: I have a breaker box with a 200A main breaker and I am assuming it has a legit 200A service. Right ... A: Keith, This is a common question. The thing you have to remember is that just because a circuit is ...
|
| disconnect | 10/6/2007 |
Q: I have a few questions about a sub panel disconnect and I get different answers from different ... A: Craig, I am confused a bit, so humor me a minute. Why are you installing a 60 amp sub panel? Why ...
|
| wiring a Hudson Bay fan | 10/5/2007 |
Q: I wired a remote control Hudson Bay fan but not the kind that can reverse the fan blades. This ... A: One hot was for the fan, and one hot was for the light. Your remote now does the work of the two ...
|
| electric furnace | 10/5/2007 |
Q: I bought a used electric furnace to heat my garage. It was a temporary heat source for a home under ... A: Jeff, This is the correct way to ground your furnace. The circuit with #6 wire is for the elements ...
|
| tv plug sparking | 10/5/2007 |
Q: Television is turned off, but when I plug it into the wall receptacle it sparks, I've checked the ... A: A little know fact; most TVs draw power even with the switch off. There are circuits energized ...
|
| Appliance Outlet Wiring | 10/5/2007 |
Q: ...I recently changed my dryer cord from a 3 prong to a 4 prong. The dryer runs but does not heat ... A: It sounds like you are getting 120 volts instead of the 200 volts needed to power the elements. ...
|
| disconnect | 10/5/2007 |
Q: I have a few questions about a sub panel disconnect and I get different answers from different ... A: Craig, NEC states that there has to be a disconnect "in sight" of the A/C. Whether that disconnect ...
|
| motion detectors floodlights | 10/4/2007 |
Q: Is it possible to wire two motion detector floodlights to work together as one light? I would like ... A: Yes, you can do this. Make sure all the hots are on the same phase! Either detector turns on ...
|
| plug gets hot to the touch. | 10/4/2007 |
Q: I own a house that was built in 1942 and has most of its old wiring. I have gas heat on my main ... A: Mike, "Hot" is a relative term. Most plugs for heaters get warm because of the amount of amps for ...
|
| Wire size for 150amp main box | 10/3/2007 |
Q: I am looking at buying a hot tub and realized that it requires a 50amp single phase breaker. The ... A: The 600v just means that the wire is rated up to 600 volts. That has nothing to do with the ampacity ...
|
| wiring on lights | 10/2/2007 |
Q: we have track lights in our living room and they no longer work..the lights in our guest bathroom ... A: Go into the guest bathroom and look for the GFCI outlet (it has a button in between the upper and ...
|
| installing switch in under counter flouresent? | 10/2/2007 |
Q: I took out the old switch & got the wireing all confused. Now I don't know how to rewire & install ... A: A diagram won't help if you don't which wires are which. Basically, power gets connected to one ...
|
| Wire size for A/C compressor | 10/1/2007 |
Q: Grey, I am adding a sub-panel and happen to notice in my new house that was just built this ... A: You are correct in your concern. I would call the builder and explain the problem and ask to have it ...
|
| wiring a switch/outlet | 9/30/2007 |
Q: in wiring a switch/outlet, i ran into difficulty. i wired the 2 dark screws with the hot wire, i ... A: Your two dark screws should have a jumper between them. This is where your "hot" wires attach. The ...
|
| voltage low in part of circuit | 9/29/2007 |
Q: I have a circuit that feeds the lights and recetacles upstairs in my home. About 4 ceiling lights ... A: Assuming that your meter is working correctly and you were testing hot to neutral then my next step ...
|
| Air Compressor Timer | 9/28/2007 |
Q: I forgot to turn off the circuit breaker to my air compressor last night. Well, during the night it ... A: Does this need to hold pressure 24 hours? If not, I would wire up a switch to a timer that when the ...
|
| amps | 9/28/2007 |
Q: I have a 240V circuit that runs from 2- 120V, 20 amp breakers. Is the 240V circuit 20 amps or 40 ... A: You have 20 amps at 240 volts = 4800 watts You are limited by two factors: Wire size & Breaker ...
|
| wiring a light switch | 9/27/2007 |
Q: I want to connect a switch to control the outside light in my home. the source is at a three way ... A: You will need access to a hot and a neutral. See if you have both of these at the 3-way switch. If ...
|
| Welder Hook Up | 9/26/2007 |
Q: I recently purchased a Miller welder M-225P AC. Specs are: AC arc welder Volts 575 Ampers 15 ... A: The voltage seems odd, are you sure it is 575 volts? Sometimes you will read the max voltage and ...
|
| fluorescent lights | 9/25/2007 |
Q: My old ballast is a REB-4P32-SC but all I could find at Lowes was a ICN-4P32-SC and no one there ... A: The ICN means it is low profile and electronically designed to replace a wide range of ballasts. The ...
|
| Multiple Cables Through Joists | 9/25/2007 |
Q: Good Morning Greg, I'm remodeling a detached garage into a workshop/storage rooms. My service ... A: If you are running across the joists I would suggest running them on top and then protect them on ...
|
| Titan Water heater (Tankless) SCR2-120 | 9/24/2007 |
Q: Installing Titan water heater model SCR2-120 tankless. Unit states to use 60 amp breaker with 220 ... A: If this unit does not require 120 volts you want to wire (from your 6-3) black to black on water ...
|
| hottub wiring is popping the GCFI | 9/22/2007 |
Q: The pump motor label says "connected for 115v" (there is an option for 240v - I guess internal ... A: It is possible that your GFCI tripped enough to cause internal failure so that it is no longer ...
|
| Question on wiring switched outlet | 9/22/2007 |
Q: I am replacing some of the old non-polorized 2-prong outlets in my home. Most of the wiring is ... A: One of the outlets of the duplex is hot all the time so you can plug a vacuum cleaner, stereo, tv, ...
|
| water heater connections | 9/21/2007 |
Q: My water heater quit and in the process of trying to figure out the problem, I noticed something I ... A: It really depends on the quality of your continuity tester. You will have a certain amount of ohm ...
|
| water heater connections | 9/21/2007 |
Q: My water heater quit and in the process of trying to figure out the problem, I noticed something I ... A: Bob, I know it sounds confusing with the 10-3 no ground to 10-2 with a ground. But is sounds like ...
|
| Double Oven connection | 9/20/2007 |
Q: I recently replaced a double wall oven with a new one. The old one had the neutral connected to the ... A: The whites get wirenutted together and you can only have one ground wire under a screw so you will ...
|
| Double Oven connection | 9/19/2007 |
Q: I recently replaced a double wall oven with a new one. The old one had the neutral connected to the ... A: Lou, It use to be acceptable to wire the ground and neutral together on 220 volt appliances. Code ...
|
| wiring application leaving me stumped | 9/19/2007 |
Q: About me, I came from the field (substation maintenance) into ITT 12 years ago so I have knowledge ... A: Randy, Both the "hot" and neutral carry current. In fact, a lot of times a ground is actually ...
|
| Electrical problem with 2 circuits | 9/19/2007 |
Q: A 52 inch plasma Samung Tv is on a 20 amp circuit. A 50 amp gfi 220v circuit is a seperate circuit ... A: In my area, you have to put the GFI Disconnect near the hot tub. So do you have one in the panel and ...
|
| 240 v wiring/ Concession Trailer | 9/18/2007 |
Q: The plugs have four wires and I need to replace an outlet that has been moved I don't know which ... A: The best way to tell is with a voltmeter. The two wires that register 240 volts are the two hots, ...
|
| Sub Panel | 9/18/2007 |
Q: I would like to install a sub panel on the oposite side of my home for some new pool equipment and a ... A: Rick, Ah, that makes sense. I have to ask because 3 phase is a totally different beast. If you ...
|
| Electrical problem with 2 circuits | 9/18/2007 |
Q: A 52 inch plasma Samung Tv is on a 20 amp circuit. A 50 amp gfi 220v circuit is a seperate circuit ... A: Assuming all has been wired correctly and good grounds are present, it is tough to diagnose over ...
|
| Wiring to home generator sub panel | 9/17/2007 |
Q: I'm presently installing a proper manually switched 60 amp generator sub panel next to my main ... A: Of course the electrician is correct. The breaker and wire size must match the load. Otherwise your ...
|
| Converting 15 amp to 30 amp | 9/17/2007 |
Q: my wife has been taking our RV to horse shows where the are circuit panels with 15 amp receptacles. ... A: The thing you have to watch out for is accidently getting 220 volts. I am not sure I follow what ...
|
| Wire Size | 9/17/2007 |
Q: I am running 300' to a RV hookup coming off a 200amp panel. I want to set up a 100amp panel at the ... A: 6 AWG is not enough, and it is not close to being enough. I am assuming it will be just 120 volts, ...
|
| bad circuit breaker or short? | 9/17/2007 |
Q: My microwave oven recently shut off when I pressed the button. I plugged it into another outlet and ... A: Is your kitchen circuit GFCI protected? If so, look for a GFCI outlet tripped. In not, measure ...
|
| Ceiling Fan Wiring | 9/16/2007 |
Q: Why would one fan/light fixture exist on two circuits? Does this indicate a mistake somewhere? How ... A: Hopefully this was a mistake, because it is creates a dangerous situation. You will need to find the ...
|
| Wall Oven Replacement | 9/16/2007 |
Q: I'm replacing a microwave/wall oven combo unit with a separate wall oven and separate microwave, ... A: Yes, keep the 40 amp breaker in the main panel to feed the subpanel. In the subpanel you will have ...
|
| open ground | 9/16/2007 |
Q: My inspection failed because "open ground" in each room I have replaced all 3 prong outlets to two ... A: You are not required to ground those old two prong outlets. You are allowed to put those adapters ...
|
| electrical wire to short | 9/15/2007 |
Q: I am replacing my dead 120v Maytag dishwasher with a new 120v Maytag dishwasher. However, the ... A: Heather, Yes, you have three options: 1. Install a Junction Box in the wall behind the dishwasher ...
|
| Service to detached garage | 9/15/2007 |
Q: Hey Greg.First, I want to thank you for your time. Quick question. I am helping a friend ti install ... A: Unless the load of the house combined with the load of the garage is going to exceed the 200 amps I ...
|
| Electric Furnace Wiring | 9/14/2007 |
Q: I have a heat pump with a Bryant air handler/electric furnace. The unit has two shut-offs that look ... A: Joel, I believe your question keeps getting thrown into the "question pool" because you really need ...
|
| Convert unused 3 prong dryer outlet to feed subpanel for attached garage addition | 9/12/2007 |
Q: I have a unused 220 V 30 AMP dryer outlet that I plan on moving into our attached garage and ... A: Joe, Interesting dilemma. My first question is "will 30 amps be enough for the garage?" If so, ...
|
| track lighting, cable | 9/12/2007 |
Q: what is the reason you can't run flexible track lighting or cable lighting thru an interior wall. ... A: Maybe I misunderstood. Are you talking about running the track cable right up to the wall and then ...
|
| third wire 220v outlet | 9/11/2007 |
Q: I am installing a dryer. The dryer has a three wire plug and the house has a three wire outlet. I ... A: It sounds like your dryer is being fed from a subpanel, where the ground and neutral are not bonded, ...
|
| Installation of combination switch/GFCI | 9/11/2007 |
Q: I am trying to install a switch /gfci combo in the bathroom of my rented apartment. I want to ... A: The two wires are for the switch and they give you the choice of two scenarios: 1. No GFCI ...
|
| Trying to identify old/odd outlet type. | 9/10/2007 |
Q: while looking for houses to purchase I came across an odd outlet type, I've looked on the internet ... A: This is an old 110 volt non-grounded outlet used prior to the 1960's. Outlets have changed over ...
|
| Dishwasher Ground (use of conduit) | 9/10/2007 |
Q: I'm trying to install a new dishwasher and discovered that the old one had been hooked up via wiring ... A: Commercial buildings often use the conduit as ground. A j-box will need to be installed in the ...
|
| track lighting, cable | 9/10/2007 |
Q: what is the reason you can't run flexible track lighting or cable lighting thru an interior wall. ... A: It is a safety issue. As you are aware, it is physically possible but not a smart thing to do. It ...
|
| GFI/REGULAR OUTLET | 9/10/2007 |
Q: I have (8) GFI outlet on a 20 amp circuit. It is possible for me to change and outlet in the middle ... A: If each outlet is its own GFCI (not a common GFCI Breaker), then each outlet should have the "hot" ...
|
| Upgrading circuit breaker from 15 to 20 amp | 9/8/2007 |
Q: Can a circuit breaker be upgraded from 15AMP to 20AMP without having to rewire? I have not confirmed ... A: 12 gauge can be on a 15 or 20 amp breaker. 14 gauge can be on a 15 amp breaker only. In other ...
|
| outdoor electric cable | 9/8/2007 |
Q: i want to run a cable outside from the basement to the attic. I want to have a dedicated line to ... A: You can run 14/2 romex but it has to be in conduit if it is on the outside. If you are trying to ...
|
| ge washing machine | 9/8/2007 |
Q: i have a ge washing machine that is not holding water in the wash tub. when you fill the machine to ... A: Without your model number I can only tell you how the older models worked. Basically this is how ...
|
| Voltage across two incoming lines to house | 9/7/2007 |
Q: What is the rms voltage between two incoming lines L1 and L2 into my house? I see in simple ... A: Do you really have three phase to your house? Rarely do you ever see three phase in the U.S. to a ...
|
| Installing a Subpanel | 9/7/2007 |
Q: I would like to install a subpanel in the basement of my church for a new technology center they are ... A: "What kind of breaker (amperage) is needed in the existing first floor panel to power the basement ...
|
| Meter and disconnect boxes | 9/7/2007 |
Q: i have a 100a meter on my house right now. I'm looking to move to a meter outside on an h-post. And ... A: I hope I understood you correctly. If not, please send me more info. Depending on the distances it ...
|
| GFI/REGULAR OUTLET | 9/7/2007 |
Q: I have (8) GFI outlet on a 20 amp circuit. It is possible for me to change and outlet in the middle ... A: If each outlet is a GFCI, as opposed to being fed from a GFCI, it is physically possible. But, if ...
|
| plug switch combo | 9/6/2007 |
Q: can you please help me wire this plug switch combo I bought from home depot. I took the face plate ... A: One side should have two screws and one side should have one screw. The side with two screws gets ...
|
| cutting a track lighting kit in half | 9/6/2007 |
Q: Recently I purchased a track lighting kit, plus one extra transformer. The electrician cut the ... A: Most lighting transformers have a minimum load wattage, so I would contact the manufacture (if it ...
|
| Clothes dryer installation | 9/6/2007 |
Q: I have a 240v three wire socket for the clothes dryer, I tested it using the voltimeter and I get ... A: New doesn't always mean good. Many products are defective right out of the box. Your voltages are ...
|
| pole to shop wires | 9/5/2007 |
Q: It will have a 220 v.water heater,220v.air compressor ,220v. A/C, and a 220v.stick welder .The water ... A: #3 is not always easy to find, so I would go with #2. Plus your long run constitutes a significant ...
|
| HVAC/Electrical | 9/5/2007 |
Q: When the AC unit (whole house unit as opposed to a window unit) comes on the lights in the house ... A: Richard, First thing, check voltage from your utility company at the service panel. Then check to ...
|
| pole to shop wires | 9/5/2007 |
Q: It will have a 220 v.water heater,220v.air compressor ,220v. A/C, and a 220v.stick welder .The water ... A: It sounds like you will be best served by 100 amps. I never recommend aluminum. The properties of ...
|
| lighting wiring | 9/4/2007 |
Q: I'll try to explain this as best I can. I have two ceiling lights, two sets of under cabinet ... A: There is a way to have a main switch turn the power off to all of the individual dimmers and then ...
|
| wiring 2 gang | 9/4/2007 |
Q: I have two light switches in a 2 gang box that individually control 2 seperate lights. Power from ... A: All whites get connected together. The black from the panel goes to switch one and switch two. ...
|
| electric main | 9/3/2007 |
Q: My voltage changes as soon as I turn one breaker in the main box on. When all the breakers are off ... A: You need to get a qualified electrician out there asap. You most likely have a loose neutral at the ...
|
| 115V problem with fuse panel | 9/3/2007 |
Q: I am trying to find out the best way to check INSIDE of my fuse panel. Main fuse box uses 15A fuses. ... A: Bad neutral somewhere. Get your panel updated to circuit breakers and have some circuits added. ...
|
| Replacing bathroom light | 9/3/2007 |
Q: I am about to replace a light fixture in the bathroom. The new fixture has a black, white and ... A: A quick peek at the wires on the switch should tell you if it is red or black. What did the old ...
|
| lighting | 9/2/2007 |
Q: I have installed some recessed lighting in an addition on my house. I installed 5 can type fixtures ... A: The wire size is okay (14 gauge = 15 amps), but your breaker is too large. You will need to change ...
|
| Power surge throughout home. | 9/2/2007 |
Q: I recently added new circuits to my home and replaced old wiring with grounded wiring. Now when I ... A: Chances are you have too many loads on a circuit(s). You should always do a load balance when ...
|
| vanity light | 9/1/2007 |
Q: I am replacing a vanity light in the bathroom. Currently there is one switch plate with two ... A: Lisa, In a pinch, some home owners and handymen will use the ground as neutral because they feel ...
|
| spark when adjusting ceiling fan, then 0 power, no circuit breaker tripped | 9/1/2007 |
Q: Happy Labor Day! While trying to correct a wobbling ceiling fan, I noticed the black bar that ... A: The first thing I would do is check the voltage at your circuit breakers. Tripped breakers can fool ...
|
| String pull on/off | 9/1/2007 |
Q: I have a light with string pull on/off. It has beaded wire like thing as string. It has come out of ... A: Usually the string comes loose from the switch or breaks at the switch. In my experience, ...
|
| String pull on/off | 9/1/2007 |
Q: I have a light with string pull on/off. It has beaded wire like thing as string. It has come out of ... A: Most likely the switch will need to be replaced. The power source must be removed before working ...
|
| wiring a new fixing | 9/1/2007 |
Q: I have changed light fittings before. Usually there are three wires: red (live), black (neutral) and ... A: Here in the U.S., the white wire is reserved as neutral and the green or bare wire is ground. The ...
|
| mother inlaws dual ac systems going beserk | 9/1/2007 |
Q: my mother in law has had this one ac company do her service for many years and lately they have not ... A: It is possible that the thermostat wires were nicked at one point and are shorting together. The ...
|
| Upgrading Electric in home for a new furnance/AC | 8/31/2007 |
Q: Okay here's my problem, I purchased a home last October that has a Federal Pacific Stab-Lok electric ... A: The best advise I can give you is to get a second opinion from another electrician in the area. His ...
|
| breaker box issues | 8/30/2007 |
Q: I apologize if my language use is incorrect - i am not incredibly well-versed in electricial ... A: 1. You need to have reasonable access to that panel. (since I am there you would need a local ...
|
| home wiring | 8/30/2007 |
Q: I am repairing some older homeowner additions to the house wiring. My question in a nutshell is how ... A: Typically, home wiring with 110 volts is unlike more sensitive wiring (audio, video, security) where ...
|
| Splitting an exhaust and overhead light to 2 switches | 8/29/2007 |
Q: I have one wall switch in the bathroom. It operates an overhead light and an exhaust fan. This is ... A: At this point you will probably have to run another cable from either your light or fan down to the ...
|
| printer sending too much power to pc | 8/29/2007 |
Q: I have had my pc and printers hooked up the same way for a few years. I had to get a new printer and ... A: Mary, This is more of a computer issue than a residential wiring question. And it sounds like a ...
|
| Electrical wiring- blue spark | 8/28/2007 |
Q: I recently had a light switch replaced. Sometimes when I use the light switch to turn the basement ... A: Heather, You may have a switch that is made of inferior material and workmanship. Almost all ...
|
| Pool pump keeps tripping our GFI outlet | 8/27/2007 |
Q: Our swimming pool pump has been running great for 2 years. Just yesterday we have it trip our GFI ... A: It is possible with that much rain at one time, parts of the pump got wet enough for the GFCI to ...
|
| off/on main brkr & now no pwr from 1 fuse | 8/27/2007 |
Q: I turned off the main breaker for the house (Toronto, Ontario, Canada). When I turned it back on ... A: Robert, It is possible that one of the phases is not being energized from your main breaker. This ...
|
| Temp Power Svc, Connecting boxes to panel | 8/25/2007 |
Q: ME: I'm to be wiring my own new house. Ph.D.E.E, but computer electronics, not power distribution. ... A: I have two suggestions for securing the boxes: 1. Use a piece of redwood or pressure treated wood ...
|
| outdoor motion sensor light | 8/25/2007 |
Q: I replaced the plastic joints where lights swivel, and went to rehang light. Lights stay on. Looked ... A: Connie, These instructions are typical and may not apply to your light. You should have a black ...
|
| Pool pump keeps tripping our GFI outlet | 8/25/2007 |
Q: Our swimming pool pump has been running great for 2 years. Just yesterday we have it trip our GFI ... A: In my experience, it is most likely a leaky seal in the pump that allows water to enter the motor ...
|
| MasterCool Evap Cooler MC/64 | 8/24/2007 |
Q: In the installation manual it says this cooler can operate on 115 volt. Black/White/Green coming ... A: Charles, Black goes to PUMP. Black/Yellow is not used (cap it). White and White are connected ...
|
| Ceiling Fan Prob | 8/24/2007 |
Q: I have removed two working ceiling fans and have decided to install them on the porch together to ... A: Matt, Drop the 1st fan and remove the blades so you can work on it. Can you turn the motor by ...
|
| Wire size | 8/24/2007 |
Q: I am installing a small hot tub which requires a 50 amp gfci breaker so the pump and heater can run ... A: 50 amps seems a little high if this 220 volts. However, if you are going to use a 50 amp breaker ...
|
| 2 Fan/Light Combos on a 3-way circuit | 8/23/2007 |
Q: This is new construction. I have power coming in at the 1st 3-way switch. I have 2 ceiling fans ... A: Mike, I agree with doing it the way that is diagramed at that site. It will be less confusing for ...
|
| Attic Fan Thermostat | 8/23/2007 |
Q: This morning I noticed the attic fan (gable mounted) did not cycle off and it was 60 deg outside so ... A: Adam, I am glad the mystery is solved. This is a little more advanced installation, but if you ...
|
| camper | 8/22/2007 |
Q: what is the correct breaker to wire this up to my service pole it has air cond it also has abox ... A: Rob, I am not sure how an A/C can be considered to be working great if it trips the breaker. You ...
|
| Attic Fan Thermostat | 8/22/2007 |
Q: This morning I noticed the attic fan (gable mounted) did not cycle off and it was 60 deg outside so ... A: Sometimes there is an "auto" and "manual" setting on a switch. The "manual" would bypass the ...
|
| What Size service panel do I need? | 8/22/2007 |
Q: Mr Hughes, I want to upgrade my electrical service to my detached garage. My plan is to have one ... A: I recommend putting each circuit on a 20 amp breaker using 12 gauge. The lighting can be on a 15 amp ...
|
| AC WIRING | 8/22/2007 |
Q: I CURRENTLY HAVE AN AMERICAN STANDARD HERITAGE 13 3.5 TON CONDENSOR, THE UNIT SAYS MINIMUM CURRENT ... A: Theodore, Looks like your "Caps Lock" button is pushed down, but I will answer anyway. The first ...
|
| Attic Fan Thermostat | 8/21/2007 |
Q: This morning I noticed the attic fan (gable mounted) did not cycle off and it was 60 deg outside so ... A: Adam, You should not have two circuits feeding this unless it is a 220 volt motor and it is being ...
|
| circuit breaker switch popping | 8/21/2007 |
Q: My A/C unit has it's own power switch outside next to unit on the exterior wall. Approx. one month ... A: Misti, I am confused on the terminology. There should be a disconnect right next to your condensing ...
|
| Attic Fan Thermostat | 8/21/2007 |
Q: This morning I noticed the attic fan (gable mounted) did not cycle off and it was 60 deg outside so ... A: Adam, There are several ways to wire an attic fan. Often, there is a double switch that has an ...
|
| Wiring near plumbing vent stack | 8/4/2007 |
Q: I am in Texas and our city uses the 2002 NEC and the 2003 IBC. We would like to place switches for ... A: Kirsten, I am confused. Is there room between the stud and vent pipe for a box? If so, can you ...
|
| Maytag Electric Dryer | 8/4/2007 |
Q: Greg: Perhaps you may have some insight into my problem. I have a Maytag Dryer Model DE612, that has ... A: There is a thermal fuse because I looked it up in the parts list for that model. Infinity means ...
|
| wall oven installation | 8/3/2007 |
Q: Greg - I am replacing a wall oven/microwave combination with a convection/speed (convection plus ... A: David, First, no you cannot put a larger breaker on wire that is rated for 40 amps. If your wire is ...
|
| Maytag Electric Dryer | 8/3/2007 |
Q: Greg: Perhaps you may have some insight into my problem. I have a Maytag Dryer Model DE612, that has ... A: Nick, After establishing the correct voltage (which you did) I would look at the "thermal fuse". It ...
|
| changing old 2-prong outlet to a grounded 3-prong | 8/2/2007 |
Q: I just moved into an old house and would like to change a few of the old outlets so I can protect ... A: Adam, That is essentially what needs to be done. I am glad you are making the upgrade, and I ...
|
| lights wired in series | 8/2/2007 |
Q: and want them to all be turned on/off by a switch at the end of the run. I have them wired in ... A: John, To start with, they are not and should not be wired in series. I have heard the term "wired ...
|
| New duplex wiring | 8/2/2007 |
Q: I would like to "piggy-back" a 15 amp duplex receptacle outlet off of another 15 amp duplex from my ... A: Peter, It depends on how many amps your washing machine is using and how much your power tool is ...
|
| switch wiring | 8/1/2007 |
Q: I removed a broken switch and can't figure out how to replace- the old one had 2 wires pushed into ... A: Sue, First turn off the power. You need to take another black wire and wire nut the two black ...
|
| 6 =3 or 6 =2 | 7/31/2007 |
Q: my question is which wire do i need? 6-2 or 6-3 it will be run between the power co, meter box into ... A: With the 6-3 you will have 220 volts available and that is mostly good because you will have two 110 ...
|
| Breaker box sizing | 7/31/2007 |
Q: I have a 225A breaker box in my house. It is currently full and I'd like to finish my basement. ... A: Erik, I don't know if there is a load calc worksheet online or not. Basically you start with your ...
|
| Breaker box sizing | 7/30/2007 |
Q: I have a 225A breaker box in my house. It is currently full and I'd like to finish my basement. ... A: Erik, A common mistake is to simply "add up" the breaker values in a breaker box. This is in error ...
|
| Sub panel wire size. | 7/30/2007 |
Q: Sir. Installing a 100amp sub-panel to a new garage addition in my home. Running from a 200amp main ... A: David, I would go with #2 copper for the hots and neutral and #6 for the ground. You could probably ...
|
| 220 LINE | 7/29/2007 |
Q: I HAVE A 220 PLUG IN THE LIVING ROOM THAT WAS SUPPOSEDLY USED FOR A AIR CONDITION BY THE FORMER ... A: If you are on a raised foundation you simply crawl under and drill a hole under the existing box and ...
|
| GFCI installation problem | 7/29/2007 |
Q: New house wiring. Leviton 7599-W GFCI. Line in 110v measured at the line in screws. Green LED is ... A: Try a regular outlet and see if you get your 110 volts. Are you measuring from black to white, and ...
|
| Low voltage | 7/28/2007 |
Q: Since we moved into our house we have one outlet that measures 5.6 volts (not a misprint)on my ... A: More likely you have an "open" not a "short". The main culprit would be a broken wire. Are you ...
|
| wiring a new electric oven | 7/28/2007 |
Q: Can you advise me what size of wire and breaker should be installed for a new electric oven and hob ... A: I can't speak for the codes in France, and I do not know what a "hob" is. Typically here in the ...
|
| Range is hard wired | 7/28/2007 |
Q: My oven/range is hard wired. I recently bought an oven/range that requires a 240 V electrical ... A: As long as the wire is the correct gauge for your new oven then you can do one of two things: ...
|
| neutral wire between two GFCI receptacles | 7/27/2007 |
Q: The ground and neutral wires are making contact somewhere on the jumper line between two kitchen ... A: It is not uncommon for a nail to puncture the romex and short wires, and it sounds like this might ...
|
| 110 interruption | 7/8/2007 |
Q: Just installed a 110 light socket with a switch. Whenever I put in the light bulb, I no longer have ... A: I am assuming that the light is not working. This is typical of an open or loose neutral. Look for ...
|
| Bathroom wiring | 7/8/2007 |
Q: Greg, After a nearby lightning strike, the double outlets in both bathrooms are dead. This leads me ... A: Rexford, Bathroom outlets are suppose to be GFCI protected, according to the NEC. This is ...
|
| old lighting fixture | 7/7/2007 |
Q: I have an older light fixture pair in a bathroom. When removing the older light fixtures some of ... A: Turn the power off and pull the switch out far enough to look at the wires. What do those wires ...
|
| Home Amperage | 7/7/2007 |
Q: Is the Amount of Amperage a builder put in a home based on the sq. ft of the home? And does each ... A: The sq. feet is one part of the equation. A load calculation should be done that will give a more ...
|
| power surges | 7/6/2007 |
Q: I had an electrician replace my main panel. Ever since I have been getting power surger! Now they ... A: My second question is why was the main changed? Then my comments are these: You need to establish ...
|
| 300 or 400 amp service | 7/5/2007 |
Q: I have a 200 amp service with a Cutler-Hammer 40 slot box and have six empty slots. I have an ... A: I would contact the utility company to see if your meter and service will support a 225 amp panel. ...
|
| Dryer Outlet?? | 7/5/2007 |
Q: We just bought a new Dryer. I checked to make sure before we left whether the outlet was a 3 or 4 ... A: Nick, Technically you cannot have a 50 amp outlet on a 30 amp circuit breaker with 10 gauge. Make ...
|
| Well Pump Wiring Problem | 7/3/2007 |
Q: Here it is - this one is weird. I am re-wiring my old sprinkler system to convert it from ... A: Dennis, It sounds like we need to clear up some terminology. May I assume that when you say relay ...
|
| 300 or 400 amp service | 7/3/2007 |
Q: I have a 200 amp service with a Cutler-Hammer 40 slot box and have six empty slots. I have an ... A: Jim, There is a chance you will have voltage drop problems if you do not upgrade or add another ...
|
| GFCI Circuit | 7/3/2007 |
Q: I have a GFCI circuit that does not work. The GFCI receptacle does not work as well as three other ... A: They are probably being fed from another GFCI outlet that is tripped. Once it took me awhile to ...
|
| Flickering Bulb | 7/2/2007 |
Q: Hey how are you? Just a small question.... When i turn on my closet switch the light flickers, so i ... A: Most likely the switch needs to be replaced. The power has to be turned off to replace it. I would ...
|
| Spa Issue | 7/2/2007 |
Q: I am looking for troubleshooting assistance. I have a Leisure Bay spa that seems to keep having ... A: Chad, Check for water residue on the control panel. Once, after installing the wiring for a spa I ...
|
| GFI outlets issue | 7/2/2007 |
Q: My GFI outlet in my yard shed would not "test" nor is there power on it. I replaced the GFI outlet ... A: There are two ways to wire a second outlet from a GFCI outlet. One is to wire it in parallel, ...
|
| Dead Wall Socket??? | 7/1/2007 |
Q: Turned the air conditioner on (tv shared other socket). Circuit breaker didn't trip. Tripped main ... A: Without having a voltmeter it is hard for you to tell what is going on. First, make sure you turn ...
|
| 220V 30 amp A/C | 6/15/2007 |
Q: I am replacing a 220V AC with 20 amp plug with a 220V 30 amp plug Unit. (badge says 230V 14.4amp- it ... A: It is all one "unit" but it serves two 220 volt circuits independent of each other. Basically it is ...
|
| Electric Water Heater in Mobile Home | 6/15/2007 |
Q: I purchased a water heater, Whirlpool,30 gal, from a friend. I have replaced both heating elements.I ... A: Cindy, I am sorry about your problems. Mobilehomes are different beasts than regular homes and ...
|
| 220V 30 amp A/C | 6/15/2007 |
Q: I am replacing a 220V AC with 20 amp plug with a 220V 30 amp plug Unit. (badge says 230V 14.4amp- it ... A: Brian, What you are telling me is that the two double poles are tied together so that four breakers ...
|
| lighting | 6/14/2007 |
Q: I have 3 can lights in my bathroom I would like to replace. Can I replace with hanging pendants or ... A: Debra, Supposing that the lights are all in acceptable areas, there are lights that fit right over ...
|
| How do I know that my house is safe | 6/14/2007 |
Q: Recently, a downed powerline struck the ground wire that led to my home. It backfed into the ... A: I am sorry that this horrible event happened to you, but I am glad no one was hurt. You are right ...
|
| European espresso maker | 6/13/2007 |
Q: You answered a previous question on a Nespresso machine from France, but the solution did not work ... A: Charlie, Coffee machines use heating elements to create steam and it is the pressure that moves it, ...
|
| remodel garage | 6/13/2007 |
Q: A friend and I are converting a two car garage into two bedrooms and a hallway / entrance. Currently ... A: The answer is yes, 8 general purpose outlets are fine. One thing to consider is what will be ...
|
| Flourscent light | 6/13/2007 |
Q: I believe that the new code for kitchen is now to have a flourcscent light - I do not want to ... A: What type of "holder" do you have now? These type of lights are made to fit most incandescent ...
|
| SERVICE TO FIREWORKS STANDS | 6/13/2007 |
Q: I'm getting started on running electric service to 2 fire works stands from a main panel behind a ... A: Dean, Your lighting load is 10 x 60 watts = 600 watts 600 watts / 115 volts = 5.2 amps However, you ...
|
| SERVICE TO FIREWORKS STANDS | 6/12/2007 |
Q: I'm getting started on running electric service to 2 fire works stands from a main panel behind a ... A: Dean, Stop. There are some problems here we need to work through. You will have to answer some ...
|
| Circuit Breaker | 6/12/2007 |
Q: How do you test to see if a circuit breaker is able to break? I tried shutting off 1 breaker at a ... A: Steve, As an electrician, I would hook up my device that finds breakers for certain circuits. If ...
|
| 50 hz and 60 hz cycles. | 6/12/2007 |
Q: i bought some electronic items (plasma tv) in australia with 220-240volt 50hz, i will be bringing ... A: rhoneil, Most likely you will experience problems. 50hz moves at a different speed than 60hz, so ...
|
| a/c outlet 220 volts 15amp wiring | 6/11/2007 |
Q: Greg, my question is about installing a new thru wall air conditioning. Most of the a/c I see for ... A: Elm, If your A/C pulls 15 amps then 14 gauge, which is rated for 15 amps, would be right on the ...
|
| Detached Workshop | 6/11/2007 |
Q: With apologies for what might be a stupid question. I'm thinking or running power to my workshop ... A: Hmmm, how to describe a pigtail? A pigtail is a wire added to a circuit to connect the circuit to ...
|
| lighting | 6/11/2007 |
Q: We had a house built two years ago - didn't realize till it was move in ready that there were no ... A: Karen, There are two ways to do this: Run romex from the ceiling (in the attic) down the wall to ...
|
| Detached Workshop | 6/10/2007 |
Q: With apologies for what might be a stupid question. I'm thinking or running power to my workshop ... A: No apologies required, and this is not a stupid question. At first, it would seem to reason that two ...
|
| a/c outlet 220 volts 15amp wiring | 6/10/2007 |
Q: Greg, my question is about installing a new thru wall air conditioning. Most of the a/c I see for ... A: I am not familiar with the codes in your region, but here is what you have to do to comply with the ...
|
| Electric dryer | 6/10/2007 |
Q: How do I wire my home up for an electric dryer? It is just a regular household recepticle right ... A: It sounds like there was a gas dryer hookup and now you want to change it to electric. If this is ...
|
| 220v to 110v | 6/9/2007 |
Q: I installed a new, built oven/microwave unit. The old unit had a 110v plug in for the microwave that ... A: If they are two separate units then they each have to have there own disconnect means. The code ...
|
| Standby Generator | 6/8/2007 |
Q: I have a 5500 watt portable standby generator to use during the not too frequent power outages that ... A: I would not back feed your circuits without the proper transfer equipment. Like you mentioned, it is ...
|
| A/C DISCONNECT SWITCH | 6/8/2007 |
Q: IS A FUSED DISCONNECT SWITCH REQUIRED AT THE CONDENSER ON A SPLIT SYSTEM 3 TON... IT HAS A HVCR ... A: The National Electric Code requires that a disconnect be present within site and within 50 feet. In ...
|
| Appliance Surge Protection | 6/7/2007 |
Q: Just purchased new washer/dryer set, and was wondering what sort of protection would be appropriate ... A: Art, I am not familiar with anyone using a surge protector for a washer/dryer set. We use the ...
|
| separate control of light and fan | 6/7/2007 |
Q: I had two light fixtures in the same room. Decided to change one with a hunter fan w/ lights. Works ... A: Maria, You would need to run another wire from the switch to the fan to be able to operate the fan ...
|
| 110v outlet from 220v supply | 6/7/2007 |
Q: 220v AC sytem is our standard. I have a 110v computer controlled air conditioner from Japan. It runs ... A: Jess, How many amps does your A/C draw? If you have 110 volts and a 1500 watt transformer then, ...
|
| flickering lights and brief power outage | 6/6/2007 |
Q: We've noticed flickering lights on some of our electrical circuits for several weeks (single family ... A: It seems that the only thing these all have in common is the breaker box. Since no breakers were ...
|
| 10-3 plug to 10-4 recepticle | 6/6/2007 |
Q: I have a 220v three prong recepticle that I am connecting a long 10 guage extention cord to so that ... A: The reason you have a 4 wire cord is because it is carrying 110 volts, along with 220 volts. If you ...
|
| Bathroom fan | 6/5/2007 |
Q: Here's the setup... I have 2 lights, an exhaust fan and 2 (special time delay) switches. Each switch ... A: Interesting. I see what you are doing and it is very simple. Just run a relay in parallel with ...
|
| making a part of a gfi outlet switched an the other part unswitched | 6/5/2007 |
Q: I have a GFI located about 12 feet on my outside wall. I have an awning pluged into one receptacle ... A: The answer is "no" there is no tab to break away. A gfci outlet is totally different than a regular ...
|
| changing a double plug to a plug/switch | 6/5/2007 |
Q: I have a light to a sports court with a plug on the side of the post. I want to use the plug to run ... A: My first impression is that you should get an electrician to do this for you. You indicate that the ...
|
| main circuit breaker | 6/4/2007 |
Q: One of the two main outside circuit breaker keeps tripping, usually during late afternoon/evening ... A: Doubtful it is a short. I am curious when you say one of two main circuit breakers outside. To me ...
|
| Converting a 20 amp 125/240 4 pronged outlet to a 3 pronged | 6/3/2007 |
Q: I have a generator that comes with a 20 amp 125/240 4 pronged receptacle. I want to run a table saw ... A: Lets discuss the difference between a 4 pronged and 3 pronged receptacle and then it will be clearer ...
|
| installing chandelier | 6/2/2007 |
Q: I BOUGHT CHANDELIER WHICH GOT 3 WHITE WIRES N,L E AND ONE GREEN WIRE.IN JUNCTION BOX ON CEILING I'VE ... A: Sara, Do the instructions indicate what the "E" wire is for? To me it sounds like the "N" is ...
|
| new breaker box in shop | 6/2/2007 |
Q: We recently bought a house tha has a 24 x 24 shop but no power to it. Closest power is a 110 outdoor ... A: You supposed right about the outlet not carrying a 125 amp panel. 125 amps sounds like a little ...
|
| 10-3 plug to 10-4 recepticle | 6/2/2007 |
Q: I have a 220v three prong recepticle that I am connecting a long 10 guage extention cord to so that ... A: Chad, When you say 10-3 extension cord, are you talking about black, white, and ground? When we ...
|
| 200 amps not enough? | 6/1/2007 |
Q: This is new construction with my husband and I finishing the electrical (done to rough in by ... A: How did this happen? Poor planning. How do you proceed? With better planning. Do you need addt'l ...
|
| AC disonnect | 6/1/2007 |
Q: how do I hook up a AC disconnect with a dual pole breaker to a single pole AConditioner? Hope it ... A: A single pole A/C indicates a 120 volt A/C, in which case you would not need a double pole ...
|
| I can't turn the light off! | 5/31/2007 |
Q: Yesterday my husband and I hung a new door in our laundry, and we also changed (lowered the ... A: It is possible that this a simple coincident. The light may be broken in the "on" position even if ...
|
| 220v, 20a A/C Receptical | 5/30/2007 |
Q: I am running a dedicated 220/240 line for my A/C, using recommended 12/3 w/ground, and the ... A: I am curious to find out who recommended 12/3 w/ground. If you truly need 12/3 w/ground, that means ...
|
| Bathroom fixture | 5/29/2007 |
Q: I'm replacing an old bathroom light fixture that includes a receptacle. The way this old fixture ... A: The codes are pretty much for new work because the costs of bringing older homes up to new codes ...
|
| electrical | 5/28/2007 |
Q: I have a 3 wire coming from a ceiling fan/light combination Red,black,white and green ground.. It ... A: Either the black or red was for the light, and the other was for the fan. The white is neutral, and ...
|
| Sub Panel Circuit Breaker wiring to outlet | 5/26/2007 |
Q: I've added a circuit breaker to the sub panel and connected the black wire (not the white yet.) ... A: This is an interesting problem. Let me ask you a few questions. How old is the subpanel? Are the ...
|
| wiring color conventions | 5/25/2007 |
Q: I am installing three way switches and have run 14/3 wire with red, black and white wires (plus ... A: Bob, I would wire the hot to the black screw on one 3-way switch. Then I would make red and white ...
|
| wire size | 5/24/2007 |
Q: if i wanted to run a 65 amp load center to my garage 100 ft away from the main panel what size romex ... A: Terry, Is this an attached or detached garage? Have you changed your mind from the 65 amp load ...
|
| wiring color conventions | 5/24/2007 |
Q: I am installing three way switches and have run 14/3 wire with red, black and white wires (plus ... A: There are no rules for the colors and a lot depends on where the power is coming it at. Let me ...
|
| How to make outlets flat with the backsplash? | 5/24/2007 |
Q: We are installing kitchen countertop and a backsplash (about 1" thick) and we know that it will ... A: There are extensions available for the existing boxes. Just check with your local home center and ...
|
| Kitchen Wiring | 5/23/2007 |
Q: I live in MA and we're looking to update the electrical wiring in our kitchen during an upcomming ... A: I love that state and have visited it several times. However, I live on the other side of the ...
|
| condo central smoke alarm | 5/23/2007 |
Q: I just moved into an old condo that has been renovated. It has 2 central smoke alarms that buzz ... A: Where are the smoke alarms located in regards to your kitchen? How large is the condo? Does your ...
|
| Service Entrance Wire Size | 5/23/2007 |
Q: I am building an new home with 400 amp underground service. The electric company will not mount the ... A: (drooling) Nice! 400 amps, everyman's dream. I have a question. How exactly do you plan on ...
|
| wiring length | 5/23/2007 |
Q: Hey.. I want to put a pump at the back of my pond. Ive already put one at the front.From my shop I ... A: You can run a single span, but you will want a disconnect or gfci real close by. The size of wire ...
|
| whirlpool wiring | 5/22/2007 |
Q: I am replacing a whirlpool tub where another was...the new tub specs say it requires two 15 map ... A: Good question. You will need to contact the manufacture or service department from where you bought ...
|
| lighting | 5/22/2007 |
Q: We have 3 identical light fixtures in the 1984 home we just purchased. One in a hallway, kitchen, ... A: A couple of things could be the problem; Your light bulbs are the wrong type, Your light bulbs are ...
|
| wiring fluorescent fixture | 5/22/2007 |
Q: I have two four-tube fluorescent fixtures that I was given from a commercial store that was changing ... A: All of your black wires and all of your red wires should be hooked up to the hot wire from your ...
|
| residential electrical problem | 5/22/2007 |
Q: I have a house in the middle Georgia area that was constructed in 2005. Since we moved in in ... A: Actually, most clothes irons draw somewhere between 10 and 12 amps. So it may be small in size, but ...
|
| adding a second breaker box | 5/22/2007 |
Q: I am having a problem adding a second beaker box to accommodate more power being added for a ... A: Remove the wires from the breakers and see if the breakers still trips. If it doesn't trip, ...
|
| sub panel | 5/22/2007 |
Q: i installed a 200 amp main breaker sub panel in my house next to the main panel, but i am only ... A: There is not enough information to be decisive. How far away is the pool, how far away is the well ...
|
| 220 Dryer Outlet | 5/21/2007 |
Q: I have a 220 outlet that recently blew as I was replugging the dryer into it. It knew it tripped the ... A: It sounds like something is either miswired, or you have a wire that is shorted. Please give the ...
|
| Ceiling Fan instilation | 5/21/2007 |
Q: I am trying to replace a ceiling fan/light fixture where one was already located. When the original ... A: This sounds correct. The only way to know for sure is to test for power with a volt tester. My best ...
|
| how to wire a 240v switch | 5/20/2007 |
Q: I replacing a 240v 30-amp double pole single throw switch. There are no instructions on where to ... A: Thom, There should be 5 screws. One is a ground and is green. Here is a diagram of how most DPST ...
|
| wiring problem | 5/20/2007 |
Q: "Okay, we are mystified. GFI circuit in bath worked fine until I used a hair dryer for a length of ... A: What I would do at this point is find where you are losing power. Start at the breaker. If the ...
|
| troubleshooting ghost power and undervolt in flourescent light circuit | 5/19/2007 |
Q: I had a bad short in a wall receptacle in my workshop that wouldn't throw the breaker and arced for ... A: I have been working with florescent lights since 1979, and I can't wait for them to be replaced with ...
|
| remodeling with non-IC recessed cans | 5/19/2007 |
Q: My wife selected some recessed lights that are really cool. They have them in remodel vs new ... A: I am guessing that if you have an earthquake large enough to move your insulation in the attic then ...
|
| gfi's | 5/19/2007 |
Q: the load wires have power until I connect gfi-the line wires prior to connecting to the gfi have no ... A: Your power is connected to the "line" screws. If you have other loads (outlets usually) that you ...
|
| Hot tub GFCI | 5/19/2007 |
Q: would you consider answering a hot tub wiring question? Here it is. I am replacing an older 220V ... A: This is a good question. Your old Hot Tub did not have a ground? The rest of your hook up sounds ...
|
| Circuit breaker box | 5/19/2007 |
Q: During a recent storm, water ran in to the panel box down a main wire. It filled the bottom of the ... A: Ah, but where do you plug in the hair dryer with the power off? Yes, you should be concerned. I do ...
|
| Recessed lights BX cable or Romex? | 5/19/2007 |
Q: I would like to install recessed ceiling lights in my kitchen. After reviewing several basic wiring ... A: BX is used in areas that are exposed, are in an area of danger to the wires, or in a commercial ...
|
| switch a 4way | 5/18/2007 |
Q: is it possible to pull a HR to a 4 way switch, how do u cut it in... also can u switch a 4 way ... A: In a 4-way circuit you can pull the power in at any spot in the circuit. So yes, you can pull it to ...
|
| wiring problem | 5/18/2007 |
Q: "Okay, we are mystified. GFI circuit in bath worked fine until I used a hair dryer for a length of ... A: Just so I understand, are the outlets regular outlets that are on a GFCI circuit breaker in the ...
|
| 3-way /4-way switches and continued circuit | 5/18/2007 |
Q: The web page didn't have a follow-up button so I am continuing our discussion here. Your second ... A: Ah, there you are Shirley. Okay, we have beat this! I posted a new diagram of what you need to do ...
|
| Vacuum Cleaner | 5/18/2007 |
Q: Buying something 1400 watt or amp, What is the difference? What is a stronger power and why? A: This is a good question. A lot of people are confused over this, especially when comparing 220 ...
|
| ceiling fan cabling | 5/18/2007 |
Q: Greg, my fan box has 4 cables: black, white, red and green. I did not use the red on at all and now ... A: What kind of wall switch are you using to control the fan? Have you checked the power from red to ...
|
| changing to 110 | 5/17/2007 |
Q: I just had a screen porch built and want to put in a ceiling fan. There is a box inside the porch ... A: Your black wires should be the hot wires, the white wires are your neutrals, and the bare wires are ...
|
| 14/3 wiring | 5/17/2007 |
Q: I have had a new circuit added to our panel. The electrician used 8/3 wiring on a 120V 40A GFI to ... A: Craig, I am glad it now works. And I am sorry that you had to go through all of this. Notice I said ...
|
| 3-way /4-way switches and continued circuit | 5/17/2007 |
Q: I would like to install 3 can lights in the hallway of my unfinished basement. There is a 3-way ... A: Okay, no problem. I think we are getting there. I am sure this is entertaining for all of those ...
|
| power to an out building | 5/17/2007 |
Q: "I want to run power to an outbuilding. I was going to use a double 30 amp breaker in my main box so ... A: Ah, good question. Many people get confused over this double pole breaker thingy. What you see ...
|
| 14/3 wiring | 5/17/2007 |
Q: I have had a new circuit added to our panel. The electrician used 8/3 wiring on a 120V 40A GFI to ... A: . Craig, I believe I understand. There are a few things wrong here and it would be in your best ...
|
| Old 220 to garage subpanel? | 5/16/2007 |
Q: Greg! My house has 100a service. I have an electric dryer that I want to replace with natural gas. ... A: Good question. I don't know how far your dryer is from your main panel, and that is going to be the ...
|
| 14/3 wiring | 5/16/2007 |
Q: I have had a new circuit added to our panel. The electrician used 8/3 wiring on a 120V 40A GFI to ... A: I may be a little confused so please bear with me. Your subject states 14/3 and your question is ...
|
| Rewire plug | 5/16/2007 |
Q: I am replacing a plug on an older cord that has white, green, and black wires. I assume the black ... A: The black is the "hot" wire and connects to the smaller terminal (usually gold or black), the white ...
|
| Overloading an outlet | 5/16/2007 |
Q: I have an outlet with a surge protector connected to a PC/Monitor+printer. I am getting a second ... A: I am sitting at my computer and I have two plugged into the same surge protector. Sometimes I have ...
|
| 3-way /4-way switches and continued circuit | 5/16/2007 |
Q: I would like to install 3 can lights in the hallway of my unfinished basement. There is a 3-way ... A: . Shirley, Okay I see. Yes this is a little deep and made me think a little bit. We can do this. ...
|
| changing 240 to two 120's | 5/15/2007 |
Q: I live in the country and have built a shop 110 feet from my house and I want to run a buried cable ... A: Rylan, If you notice on your main panel the neutral bar is "bonded" to the case of the panel, or to ...
|
| 3-way /4-way switches and continued circuit | 5/15/2007 |
Q: I would like to install 3 can lights in the hallway of my unfinished basement. There is a 3-way ... A: Let me make sure I understand what you want to do. Where is the fixture you want to get rid of? The ...
|
| New Sears Convection Stove | 5/15/2007 |
Q: Replacing 20 year old drop in stove with new Sears Convection stove. Old cooktop stove had 4 wires ... A: The appliance companies have not fully switched over to the NEC's decision about 4 wire instead of 3 ...
|
| changing 240 to two 120's | 5/15/2007 |
Q: I live in the country and have built a shop 110 feet from my house and I want to run a buried cable ... A: You do not need to run 220 volts, but it is highly recommended in case you add more loads out there. ...
|
| two-way light switch | 5/15/2007 |
Q: First, forgive me if I am using incorrect terminology...I am quite the amateur! We have a light at ... A: I would replace both switches because they are most likely the same age. When you go to purchase ...
|
| Doorbell transformer | 5/14/2007 |
Q: How long do hard-wired doorbell transformers typically last? A: This is a difficult question to answer. But I will tell you that I have replaced very few just ...
|
| Switch Ratings | 5/14/2007 |
Q: I am wiring my brother's bathroom. I have installed a dedicated 20 amp circuit for this. I have used ... A: This is a good question. Much like an outlet, the amperage rating of a switch is directly related ...
|
| wiring to a window air conditioner | 5/14/2007 |
Q: I have a dryer receptacle that goes to a sub box to two 30amp breakers together. If I wire my 250v ... A: Okay, I understand now. You will have to change the breaker to a double pole 20 amp breaker. If ...
|
| converting my table saw to 220 | 5/13/2007 |
Q: I installed a 220 outlet to run my Rockwell Delta table saw. I have 110 on both legs of the ... A: James, Is the switch a double pole/single throw? Or are you just wiring both legs to the same screw ...
|
| home electrical interference | 5/13/2007 |
Q: Every time any large electrical appliance is used in my house, like AC, vacuum or the disposal we ... A: This is a good question. When I worked for WP and GE on their major appliances I received this ...
|
| Subpanels | 5/13/2007 |
Q: I'm sure this has been covered, but I could not find an answer. Here goes. I moved into a newly ... A: Good question. I am not a huge fan of Square D and this is one reason why. Square D makes grounding ...
|
| bad power bill | 5/12/2007 |
Q: We had a unusally high bill last month. We did have a breaker that needed to be replaced with one ... A: . Hi Cindy, I am assuming by "bad ground" he means that it doesn't exist or there is a poor ...
|
| Wall Heater | 5/12/2007 |
Q: I purchased a 220 wall heater. The unit only has two wires and a ground screw. I ran 10-3 with ... A: It sounds like this unit does not need a neutral. Your water heater is a good example of a 220 volt ...
|
| one light fixture not working | 5/11/2007 |
Q: Suddenly my outside porch light is out. Changed bulb. Changed fixture(wanted to do this anyway), ... A: The only way to troubleshoot this problem will be to get a voltage tester. Most home centers sell ...
|
| Three-way switch to recessed lights configuration | 5/11/2007 |
Q: Mr. Hughes: I'm replacing the old kitchen lights in my house with nine recessed lights. I have ... A: Aaron, Okay, with this additional information I can see that it will not work with the wires ran. ...
|
| dryer wiring | 5/11/2007 |
Q: Greg, I want to rewire a dryer for a sweet elderly Grandma who is raising 3 gandchildren. She just ... A: Okay, you guys have shamed into telling you how some people recommend you doing this. Waiver: I do ...
|
| Connecting Sub- Panel | 5/11/2007 |
Q: I need to connect a sub panel to Main power panel. The run is 80 feet, will be run outside on side ... A: Larry, You can pull more than the 70 amps at a given time so I would go up in size. You should run ...
|
| wiring a 4 way dimmer | 5/11/2007 |
Q: I have a light in my dining room that is controlled by 4 way switches (3 switches). I want to put a ... A: Wayne, A 4-way is made up of two 3-way switches and one 4-way switch. So you will need to find the ...
|
| Three-way switch to recessed lights configuration | 5/10/2007 |
Q: Mr. Hughes: I'm replacing the old kitchen lights in my house with nine recessed lights. I have ... A: Aaron, There was an easier way, but we should be able to do it with your existing wires now. Let ...
|
| Fan on range hood - wiring issue | 5/10/2007 |
Q: I have an old range hood and need replace the fan motor. The old fan motor has three wires (Black, ... A: The red and black are for two different speeds and have nothing to do with rotation. You have the ...
|
| changing dryer from 3 wire to 4 wire plug | 5/10/2007 |
Q: My new home requires a 4 wire plug. My dryer has a 3 wire plug. I have bought the new plug, but am ... A: I believe it will be easy. The difference between a 4 plug dryer and a 3 plug dryer is the 3 plug ...
|
| 4 prong dryer outlet | 5/10/2007 |
Q: My dryer is a newer 4 prong model. My old outlet is only 3 prong. I bought a 4 prong outlet. But ... A: Matthew, There are websites that describe how to convert your dryer from a 4 prong to a 3 prong. I ...
|
| 4 prong dryer outlet | 5/10/2007 |
Q: My dryer is a newer 4 prong model. My old outlet is only 3 prong. I bought a 4 prong outlet. But ... A: You are one of the many that got caught in the changes the NEC made to homes. Many people don't ...
|
| Connecting Sub- Panel | 5/9/2007 |
Q: I need to connect a sub panel to Main power panel. The run is 80 feet, will be run outside on side ... A: I think we can solve this. But I hate guessing. Let me know what the main panel will be feeding and ...
|
| Triple Light Switch | 5/9/2007 |
Q: I had a double light switch in my hallway. This switch powered a light at the top of the stairs and ... A: Darson, I like diagrams. But I got the picture on this. First thing we need to establish is do you ...
|
| power cords | 5/9/2007 |
Q: Is the smooth side of a power cord for lamps, appliances etc the hot or neutral wire? A: Good question. This gives me a chance to elaborate a little on light sockets for incandescent ...
|
| Triple Light Switch | 5/9/2007 |
Q: I had a double light switch in my hallway. This switch powered a light at the top of the stairs and ... A: So let me see if I understand. One switch is for the light in the stairway. One switch is for the ...
|
| Electric box | 5/8/2007 |
Q: How close can I install my water heater to my breaker panel? Is there any code problem if I do so? I ... A: I cannot find any problem with the NEC in locating it near a water heater. The NEC states that is ...
|
| 220 receptacle | 5/8/2007 |
Q: On a 220 receptacle is the center the ground ? If so why is it marked with white ? A: Long story short, the center can be either neutral or ground. If you have three wires, ...
|
| Electric range connection | 5/7/2007 |
Q: I have an old electric range that is diectly wired to the AC. Do I need to install a receptacle? 240 ... A: If you are installing a new range, then you should install a receptacle. You want to match it up ...
|
| wiring baseboard heaters | 5/7/2007 |
Q: I am installing baseboard heaters in a new room built in the back of my garage. They include one ... A: If I understand your wattage correctly do not use the 30 amp breaker, and do not use the 12/2. ...
|
| circuit breaker/hot water heater | 5/7/2007 |
Q: Greg, My circuit breaker for the hot water heater trips when the air conditioner is running, other ... A: It sounds like your water heater and A/C are on the same circuit which is not good. If both wires ...
|
| Still power with lightswitch switched off | 5/7/2007 |
Q: After replacing a Halogen lamp in GU10 fitting for a LED version (from Philips) I noticed that the ... A: Doubtful it is induction from the wiring in the tube. But it sounds like you might be in another ...
|
| receptacle in bathroom isn't working | 5/7/2007 |
Q: now you must bear with me because I am a womman! The receptacle in the bathroom where I plug in my ... A: I was waiting to hear you roar. (okay, terrible joke about the song). The moisture is most likely ...
|
| Hot Tub Install | 5/6/2007 |
Q: My wife and I are purchasing an above-ground (portable) hot tub. the ElecSpecs call for a dedicated ... A: Most of the times it is that "simple". Of course running the conduit and bending it may or may not ...
|
| hot tub wiring | 5/6/2007 |
Q: We've got a hot tub in the back yard, about 60 feet away from our breaker box. We had it hard ... A: Make sure to thank your friend for me. Taking that extension cord back was probably the best thing ...
|
| Gang box repair - replace | 5/6/2007 |
Q: I have a plastic single gang box that has a cracked thread hole for fastening the outlet to it. Is ... A: Yes there is a well, somewhat quick fix. I am assuming this is not a remodel box to start with. How ...
|
| Electric range cooktop | 5/6/2007 |
Q: We have Frigidaire Electric range with Ceramic cooktop. Two weeks back as we put on one of the ... A: If this is still under the manufacture warranty you need to talk to the service manager and explain ...
|
| main breaker in panel | 5/6/2007 |
Q: I recently looked at a new construction town home in Seattle, WA. I checked the main panel and ... A: Good questions Doug, Question #1, yes there has to be a main disconnect for the whole panel. Look ...
|
| Conversion of electric cooktop tro gas cooktop | 5/5/2007 |
Q: I have currently a 30 inch jennair downdraft electric cooktop. I would like to change to natural gas ... A: I found this in the "question pool" and this question has been in the question pool for a few days ...
|
| light fixture installation | 5/5/2007 |
Q: I have a 4ft. fluorescent 2 tube light fixture in my kitchen. It's ugly and I hate it and want to ... A: Patti, That is a pretty good sign that there may not be a box up there. But you won't know for sure ...
|
| light fixture installation | 5/5/2007 |
Q: I have a 4ft. fluorescent 2 tube light fixture in my kitchen. It's ugly and I hate it and want to ... A: Glad to help. It is likely that the box is in the ceiling above that quarter size hole. From the ...
|
| intermittent drops ni two circuits | 5/5/2007 |
Q: Kitchen lights have been flickering infrequently for the past few weeks. Recently it has gone from a ... A: . Hi Dan, I would start at the circuit breaker panel. Turn off the main breaker and tighten the ...
|
| Wiring a new switch | 5/4/2007 |
Q: .. I am wiring new recessed low voltage lights. I used 12/2 wire for the installation on the ... A: Here is the rule to remember; The wire size can be bigger than the breaker size, but the breaker ...
|
| Short in Gas Stove? | 5/4/2007 |
Q: We recently moved into an older home and installed a used gas stove that we purchased from a used ... A: Aren't older homes fun? They certainly do have a lot of character and many, many mysteries. It is ...
|
| oven wiring | 5/4/2007 |
Q: I have purchased an older Norge Wall oven with no wiring diagram. Problem: I have four wires and ... A: Brent, Awesome, I am glad it all works for you now. Those old stoves are nice. I cannot think of ...
|
| Replacing an electrical outlet with direct wire | 5/4/2007 |
Q: I have a powered air exchanger mounted high on the wall of one of the rooms of my home. It is ... A: Corey, I noted that fact, and no it does not count as a "disconnect". And I do not know of a way ...
|
| sharing nuetrals | 5/4/2007 |
Q: out of a 120/208 panel if i had three circuits sharing a nuetral and each one of those circuits ... A: Let me see if I understand what you are asking, do mean you have three circuits each with their own ...
|
| Replacing an electrical outlet with direct wire | 5/3/2007 |
Q: I have a powered air exchanger mounted high on the wall of one of the rooms of my home. It is ... A: No, this idea is not good. Here is why. Any removable appliance must have a way to disconnect it ...
|
| Generator hookup not to house circuit | 5/3/2007 |
Q: I am interested in mounting a receptacle box on the porch and running conduit through the wall to a ... A: The first question I have is how will you keep the refrigerator and sump pump from operating at the ...
|
| Trouble with New Thermostat | 5/3/2007 |
Q: I recently had a new thermostat installed for my 1st floor zone. We have 2 zone oil fired baseboard ... A: Andrew, Your t-stat is basically just a switch. There is power at one of the two wires. When the ...
|
| 110 to 2220 upstep transformer | 5/2/2007 |
Q: On my boat I have a 110 volt 12kw generator. My wife would like to add a four burner stove top. All ... A: I found this question in the question pool. The transformer you listed is rated at 5kW. So a total ...
|
| 120 wiring | 5/2/2007 |
Q: Greg, When I run a 120v line does it all have to be the same size by code? I needed to run a new ... A: Will an inspector bust you for this? Probably not. Here is the code: A bathroom light and outlet ...
|
| Doorbell capacitor | 5/2/2007 |
Q: My electrician installed a new 8-tone doorbell in my new home. Pushing the doorbell button only ... A: Is your new doorbell "wired" or "wireless"? Is your new doorbell electronic or electro-mechanical? ...
|
| oven wiring | 5/2/2007 |
Q: I have purchased an older Norge Wall oven with no wiring diagram. Problem: I have four wires and ... A: Brent, Yes, that is what I am thinking. It may be the power to some 110 volt components. Instead ...
|
| spa sub panel | 5/2/2007 |
Q: I am wiring a 2-pole 50 amp gfci breaker sub panel for a sundance spa. I only have 3 wires coming ... A: Okay Kevin, Yes, to work correctly you will need 4 wires from your main panel. The neutral is ...
|
| 3 prong outlet, 4 prong dryer plug | 5/2/2007 |
Q: I just bought a used, but fairly new electric dryer. When I got it home, I noticed that while the ... A: Yahoo, no more laundromat! Your house was built during the time the "powers that be" decided that ...
|
| spa sub panel | 5/2/2007 |
Q: I am wiring a 2-pole 50 amp gfci breaker sub panel for a sundance spa. I only have 3 wires coming ... A: The last spa I wired up I had to run 4 wires from the main box. You said the wiring diagram shows a ...
|
| power loss in mobile home | 5/1/2007 |
Q: My son loss all power to his mobile home which is butted up against ours my husband was still in the ... A: This sounds like you have some serious wiring troubles inside of the mobile home. It is very likely ...
|
| Adding additional circuit | 5/1/2007 |
Q: I have 150amp service and want to add a hot tub which needs 240 50A dual pole, I already have a 240 ... A: I load calculation needs to be done on your house to make sure you are not overloading the main. As ...
|
| electrical | 5/1/2007 |
Q: how many plugs and or switches can be on a 15amp and a 20amp breaker and why A: . Hi Darren, The answer lies in the question "what are these plugs and switches feeding". For ...
|
| swimming pool pump, heater, lights | 4/30/2007 |
Q: The 1.5 HP pump for my inground pool stopped working. At the same time the underwater pool lights ... A: You right, it sounds like an electrical problem to me too. It is possible that you lost one leg of ...
|
| Rooftp Antenna Cable | 4/30/2007 |
Q: Real quick and easy question. (I hope) I was trying to hook up my rooftop antenna and discovered ... A: There are different types of wire depending on your antenna. If there is a small piece left at the ...
|
| room receptacles and lights | 4/30/2007 |
Q: The power to one room in my double wide mobile home went out.No breaker was tripped.Replaced all ... A: You say you got two outlets to work. Are they the two that show voltage but will not operate ...
|
| two outlets, one switch | 4/30/2007 |
Q: Just purchased an older home. At the front door there are two switches. One switch is for the porch ... A: It is becoming clearer. So let me see if I understand now. You have two switches next to each ...
|
| room receptacles and lights | 4/30/2007 |
Q: The power to one room in my double wide mobile home went out.No breaker was tripped.Replaced all ... A: It is not uncommon to find broken wires in the walls of mobile homes. This sounds like the classic ...
|
| can i use a single pole switch with a three way switch | 4/29/2007 |
Q: I have a power source going into box #1 from there it lights the fan and a second switch a light. ... A: Let me see if I understand what you have. You have a light switch that is turning on/off a ...
|
| Add Ceiling Fan outlet to existing light switch | 4/29/2007 |
Q: I have an existing circuit that controls a wall light. I would like to add a new run off of this ... A: This sounds like good news for you. What we need to do is establish what wire is hot all the time. ...
|
| Wiring Exhaust Fan | 4/29/2007 |
Q: I have a question regarding wiring a Panasonic FV-08VKS1 Exhaust fan that I just purchased. I tried ... A: As I understand you, there are three wires on your exhaust fan. Black, Red, and White. Does the ...
|
| Pool Pump | 4/29/2007 |
Q: I am in the process of buying an 18' above ground ground pool. They offer a 1.5 HP motor or a 1.0 ... A: Here are some of the answers to your questions: 1. Voltage supplied varies from region to region. ...
|
| clicking sound from recessed lights | 4/29/2007 |
Q: Our house was built two years ago. Towards the end of the building process, while I painting murals ... A: I am sorry, but I just laughed out loud at your last paragraph. Okay, the grounding is a serious ...
|
| Wierd Problem - Please Read | 4/29/2007 |
Q: I have a mobile home, '78 model. All at once, weird things started happening. I tested and found the ... A: Just to clarify, your whole system is single phase as opposed to three phase. But I understand what ...
|
| two outlets, one switch | 4/29/2007 |
Q: Just purchased an older home. At the front door there are two switches. One switch is for the porch ... A: I found this question in the question pool and thought I would give a stab at it. Right off the bat ...
|
| Adding circuit for A/Cwith Heat | 4/28/2007 |
Q: I am considering addng Air conditioning with a 15kw/240v heater coil. I currently have a single ... A: Rich, I would need to run a load calc on your house to be sure, but it sounds like your 125 amp ...
|
| GFCI Circuit | 4/28/2007 |
Q: I have a GFCI circuit that does not work. The GFCI receptacle does not work as well as three other ... A: Does the circuit with the GFCI protection have a GFCI breaker (in the circuit breaker panel), or ...
|
| clicking sound from recessed lights | 4/28/2007 |
Q: Our house was built two years ago. Towards the end of the building process, while I painting murals ... A: First off let me apologize on behalf of the brotherhood of electricians for the trouble and comments ...
|
| Trouble with New Thermostat | 4/28/2007 |
Q: I recently had a new thermostat installed for my 1st floor zone. We have 2 zone oil fired ... A: I love these kind of problems and wish I could be there to do it person. Right now I live on the ...
|
| oven wiring | 4/27/2007 |
Q: I have purchased an older Norge Wall oven with no wiring diagram. Problem: I have four wires and ... A: Okay, That eliminates the blue as ground. Some of the old ovens used a bluish/green for ground. ...
|
| Questionable ground in three-prong outlets? | 4/27/2007 |
Q: Greg, A house I'm renting has a mix of two- and three-prong outlets. All but one of the ... A: Chris, Yes, this is a possible safety hazard. It sounds like the ground wire has either come loose ...
|
| 220Volt-related question | 4/27/2007 |
Q: I'm traveling to Europe, where they have 220V standard. All my electrical items are dual-voltage, ... A: Mike, it was Greg that answered. I found the question in the "question pool" and decided to answer. ...
|
| Add Ceiling Fan outlet to existing light switch | 4/27/2007 |
Q: I have an existing circuit that controls a wall light. I would like to add a new run off of this ... A: The first thing we need to do is find out what wires are present in the box that your switch is ...
|
| 400 amp or 2 200 amp | 4/27/2007 |
Q: I currently have an upgraded 200 amp surface mount panel and meter, I was looking to upgrade to a ... A: I found this question in the question pool, and I have a few answers and a few questions. That 3500 ...
|
| 220Volt-related question | 4/26/2007 |
Q: I'm traveling to Europe, where they have 220V standard. All my electrical items are dual-voltage, ... A: I found this question in the question pool and I applaud you for your understanding of electricity. ...
|
| oven wiring | 4/26/2007 |
Q: I have purchased an older Norge Wall oven with no wiring diagram. Problem: I have four wires and ... A: Wow, Norge takes me back a ways. I use to install those a looong time ago. Nowadays, the standard ...
|
| Lighting Fixture | 4/26/2007 |
Q: I just moved into a newly built condominium and am having trouble attaching a lighting fixture to ... A: Okay Cliff, You are welcome for the assistance. It looks like the orange wire in your ceiling box ...
|
| Panelboxes | 4/26/2007 |
Q: Panelboxes I am purchasing a house that was once two apartments, and need to convert back to one ... A: Dan, Your utility company should be involved in this because each meter has a limit on the ...
|
| Panelboxes | 4/26/2007 |
Q: Panelboxes I am purchasing a house that was once two apartments, and need to convert back to one ... A: Good question. First of all you will need to get the utility company involved in this. They will be ...
|
| Furnace Wiring | 4/26/2007 |
Q: Greg, Should my gas furnace be wired on its own circuit? Currently it has been wired on a circuit ... A: Well, technically yes all HVAC equipment need to be on individual branch circuits. Here is the ...
|
| Lighting Fixture | 4/26/2007 |
Q: I just moved into a newly built condominium and am having trouble attaching a lighting fixture to ... A: Awesome photos. I love technology. Okay, I have a good idea of what is going on but to make sure I ...
|
| Non grounded outlets | 4/26/2007 |
Q: I am buying a home built in 1945. The inspection revealed several non grounded outlets, several ... A: This is a question that is really hard to answer because there are so many factors that we cannot ...
|
| chandelier wiring | 4/25/2007 |
Q: I am trying to build a 5-bulb chandelier on an old metal wagon wheel for a rustic cabin I am ... A: I found this question in the "question pool" and thought I would at least give you a few tips. ...
|
| Fridge circuit | 4/25/2007 |
Q: Do I need to have a seperate circuit put in to add a refridgerator in my garage or can I use what is ... A: This depends on the circuit size and what you have on that circuit. I do not recommend having your ...
|
| 3-Way and 4-way switches | 4/25/2007 |
Q: Ok, my lights at the top of my stairs have 3 switches for them.... two 3-way switches, and one 4-way ... A: This type of switching arrangement is awesome, until something goes wrong and then it can be very ...
|
| installing a ceiling fan | 4/25/2007 |
Q: I want to install a ceiling fan/light in a bedroom where no light fixture currently exists. There ... A: Karen, This is good news! The two black wires at the bottom of your switch are the "hot" wires. ...
|
| 3 way switch | 4/25/2007 |
Q: My light on a three way quit working both switches. If one switch was bad would the other work? Or ... A: It is possible for one of your 3-way switches to go bad and the other switch could still work. But ...
|
| Dual fuel stove | 4/25/2007 |
Q: I have four wires from my new stove. Red, Black,White, Green Green is a ground, the Black & White go ... A: Joe, Another great question and I am glad I get the chance to address the whole 4 wire versus the 3 ...
|
| feed capacity for detached garage | 4/24/2007 |
Q: I want to add a sub feed to a new detached garage which is 30 feet from an existing 200 amp mobile ... A: Fred, Ah, power and lots of it in the garage; every man's dream. Your information generates too ...
|
| installing a ceiling fan | 4/24/2007 |
Q: I want to install a ceiling fan/light in a bedroom where no light fixture currently exists. There ... A: Karen, Good question. This is really a personal choice on whether to install another switch or use ...
|
| Dead outlets | 4/24/2007 |
Q: Last fall ran a new line out to my deck, this came from a box in my basement. The line out went to ... A: Marilyn, Great answers! This sounds like it was done correct except we need to put that outside ...
|
| Dead outlets | 4/24/2007 |
Q: Last fall ran a new line out to my deck, this came from a box in my basement. The line out went to ... A: I am sorry for your loss and I will do my best to help. First question I have is did you install a ...
|
| home wiring | 4/24/2007 |
Q: Four years ago we added on to our house and also redid our existing kitchen. The company who did ... A: This problem is more common than you might think. In my experience the number one cause of this is ...
|
| electrical conduit in a pre-exisiting concrt. sub floor | 4/23/2007 |
Q: We are installing an island in our kitchen and will need to get power to it in order to be within ... A: I found this question in the question pool and didn't want to leave you hanging. Yes, there is a ...
|
| Clarification on Correct Grounding | 4/22/2007 |
Q: I am building a new home, 200amp service, all underground with a meter pedestal. The electric ... A: How far is the pedestal from the house? Your neutral is bonded to ground at the main service panel. ...
|
| Switching out light switches? | 4/21/2007 |
Q: I just replaced my upstairs hall light switch with a new one and hooked it up exactly how it was ... A: Ah, you have just ran into a problem that plagues many DIY'ers trying to replace 3-way switches. ...
|
| connecting internet | 4/21/2007 |
Q: how could a person to connect Internet from home by using a telephone A: Your telephone line plugs into a modem that either plugs into your computer from the outside, or it ...
|
| upgrade | 4/19/2007 |
Q: an electric tanklesss water heater requires 200amp service. i just recently had my electric panel ... A: You can have two service panels from one meter. They must be right next to each other. Correct me ...
|
| Residential New Construction - max # circuits | 4/17/2007 |
Q: I am building a home (could eventually be 8000 sf+) and doing the electrical work myself, but I am ... A: Mike, I agree that dividing up 200 circuits can be a headache. But I strongly advise that you get a ...
|
| 3 vs. 4 wire 220 v. range duel fuel bosch | 4/16/2007 |
Q: I have a gas range in 14 year old house. There is a 110 outlet behind stove for electric controls ... A: Todd, The safest thing to do in this situation would be to run new copper wiring to the oven. #8 ...
|
| wiring 230V cooler with 3 wire connect from 2 wire source | 4/16/2007 |
Q: I have a new walk in cooler that is 230V. the junction box has 3 wire connect, (red , black , ... A: This is a good question Mike. You say that you only have 2 wires available. Is there a ground ...
|
| wiring 220v to shop | 4/15/2007 |
Q: I have had a 12x24' shop version bldng brought in.It is prewired,for 220v with one 220v outlet,and ... A: I just read this post and see it is a few days old. The reason they leave the bonding strap on the ...
|
| Wiring Installation | 4/14/2007 |
Q: I have a Jenn Air downdraft cooktop, model 8430. There are four wires connecting to the cooktop: ... A: I found this question in the "question pool" and I see it is a little old. I am not sure if you have ...
|
| Replaced a thermostat | 4/10/2007 |
Q: Hey Don, I am looking to replace an analog thermostat with a digital one. I went to Lowe's and ... A: I found this question in the question pool and even though it is older it is a good chance to ...
|