| Subject | Date Asked | Expert |
|
| Location of return air duct. | 7/14/2009 | john t. borgman |
Q: My house currently has 8 (13.75" x 7.75") return air ducts, 4 each on the first and second floor. My ... A: Kim, First, how did your old equipment do before it failed? Second if you increase the tonnage ...
|
| new condenser | 7/14/2009 | Eric Campion |
Q: I installed a condenser unit in a friends church, they had a comfortmaker heat pump. I installed a ... A: Unfortunately our expertise is with Major Home Appliances only. This would include washers, dryers, ...
|
| Kenmore Ultra Bake Circuit Board | 7/14/2009 | Eric Campion |
Q: Have a Kenmore Ultra Bake Electronic Range. Model number 665.92142300, Serial number RP3810423. ... A: Are you speaking of your main clock/oven control? If so I can sell that to you in new for 125.99 + ...
|
| Trane Air conditioner unit | 7/14/2009 | john t. borgman |
Q: I broughta Trane 2TTX5030A1000AA heating and airconditioner unit from a local company in arkansas. i ... A: I am assuming you might have a duct problem, as, the dripping copper pipe says that the air flow and ...
|
| condensation inside freezer | 7/14/2009 | Eric Campion |
Q: I have a Maytag side-by-side MSD2660 that is only a couple weeks old. Inside the freezer, I noticed ... A: Not really sure withoout instructing you to start tearing into things. Bottomline is it is under ...
|
| Bryant central unit-Ruud outside fan | 7/13/2009 | john t. borgman |
Q: Outside fan works but I do not know how to tell if the air is warm enough coming out of it off the ... A: Don, No, it sounds like you are describing a problem with the blower motor. Do Not turn it on ...
|
| HVAC works, inside fan motor will not come on | 7/13/2009 | john t. borgman |
Q: I recently went into the furnace, pulled the covers and changed the filter only. Put the covers back ... A: Steve, The outdoor unit does not blow air inside, it moves refrigerant inside. The motor below ...
|
| Freon Problem? | 7/13/2009 | john t. borgman |
Q: Hey I have a VEXAR Coil unit heating my mobile home. I paid a guy $100 to come out and fill my unit ... A: Chad, I don't have a clue what the guy did I was not there. It is not filled inside the house. ...
|
| Trane Air conditioner unit | 7/13/2009 | john t. borgman |
Q: I broughta Trane 2TTX5030A1000AA heating and airconditioner unit from a local company in arkansas. i ... A: I am sorry to inform you that the tech is lying to you. There is no physical way your equipment ...
|
| Settings for 2 level home? | 7/13/2009 | john t. borgman |
Q: I have a general question about cost control in a 2 level house. I live in Arizona and currently we ... A: Alex, The first thing you should consider is a tstat controlled power attic fan, if you have an ...
|
| ICE MAKER | 7/13/2009 | Eric Campion |
Q: My refrigerator is a GE TFX26PPDAWW. It has waetr in the door and an ice maker. The water in the ... A: Reinstall the ice maker and then using a turkey basker, fill the mold with water. Now, walk away ...
|
| Fridge drainage | 7/13/2009 | Eric Campion |
Q: I have a Tappan refridgerator Model # TRT17NRBWO that is at least 10 yrs old. About once a week I ... A: Most often there is enough heat there to evaporate the water. Is there a fan back there not ...
|
| Residential AC | 7/13/2009 | Norval Trimborn |
Q: AC quit blowing cold, slowly getting warmer over apx. 3 month period. Had friend come charge system, ... A: The evap. coil can be pressurized to 50-100 psi and then checked the next day to if it has lost a ...
|
| Temstar heating and air conditioner unit | 7/13/2009 | Jim Barnhart |
Q: Unable to locate the model # but the unit is about 10 years old, some 4 feet in length, 2 1/2 feet ... A: Hayden, I have absolutely no knowledge of what your dealing with? Tempstar is a brand name that used ...
|
| A/C blowing from cold to hot with out changing.... | 7/13/2009 | Norval Trimborn |
Q: My a/c will run fine for as long as 2-6months, then suddenly start acting as if it has a mind of ... A: It would be difficult to tell without knowing more about the system. It seems as though you are not ...
|
| Rheem Air Handler | 7/13/2009 | Jim Barnhart |
Q: 2 Year old Rheem Classic Plus air handler sweats to the point of dripping. Installer said it was ... A: Lee, It's called condensation, that's what happens when the cold meet's the warm. It's normal for ...
|
| A/C | 7/13/2009 | Jim Barnhart |
Q: I have some heat registers in my basement, but no return air registerb whivh I could cut into the ... A: Bill, I don't know what all you have in your basement, If you install return air/airs in the ...
|
| Bryant central unit | 7/13/2009 | Craig HVAC Expert |
Q: The unit has been running for some time now and is not putting out any cool air at all - I just ... A: The fan can be at the top or bottom. It really depends on the unit. They come both ways. The fan ...
|
| Freon Loss | 7/13/2009 | john t. borgman |
Q: I believe that my unit is a heat pump, as it provides my heating and air conditioning. My question ... A: Rick, You need to crawl under your home and secure the cross over duct work, it is flex duct and ...
|
| Freon Loss | 7/13/2009 | john t. borgman |
Q: I believe that my unit is a heat pump, as it provides my heating and air conditioning. My question ... A: Rick, There is no such thing as magic, a phrase from my engineering teacher of old. Why would you ...
|
| Home AC | 7/13/2009 | Jim Barnhart |
Q: We have lived in this new construction home for about 14 months. We have central air and heat. We ... A: Kirsten, I don't know what type of "central air and heat" You have? There are gas furnaces, electric ...
|
| rv a/c no leaking water on outside of trailer | 7/13/2009 | john t. borgman |
Q: my rv a/c is not leaking water on the out side of the trailer what could be the problem ANSWER: ... A: There are a lot of things that can cause it to not condense water from the air, including a little ...
|
| Temstar heating and air conditioner unit | 7/13/2009 | Jim Barnhart |
Q: Unable to locate the model # but the unit is about 10 years old, some 4 feet in length, 2 1/2 feet ... A: Hayden, The cooling coil has a drip pan directly under the coil itself, it may be built onto the ...
|
| Maytag fridge cooling fan issue | 7/12/2009 | john t. borgman |
Q: I have a fridge (Maytag MTB2456gew) that started not working properly, so I tried to troubleshoot. ... A: Mark, FYI, I am just an expert volunteer on here. Looking to build my portfolio for making this ...
|
| A/C Question - Goodman CK-42-1B | 7/12/2009 | Howard Livingston |
Q: when that satisfying sound of the compressor springing to life stopped happening and just the fan ... A: Well hello again Don. I have been in this business since 1973 & it has always been fun(well most of ...
|
| Residential AC | 7/12/2009 | Norval Trimborn |
Q: AC quit blowing cold, slowly getting warmer over apx. 3 month period. Had friend come charge system, ... A: Did the contractor say there was a leak in the evap. coil? If they replaced the evap. coil and had ...
|
| Ruud air conditioner/blower issues | 7/12/2009 | john t. borgman |
Q: I have a Ruud model #UGDA-12EA-ER furnace with outside air conditioner unit. I turned the AC on this ... A: Jerry, Pull the front door from the furnace. To the right of the vent pipe there is a brown door ...
|
| NEW A/C CAN'T KEEP UP WITH STAT | 7/12/2009 | Fred Weldin |
Q: REPLACED OLD 3TON HP WITH GOODMAN 3.5HP.NEW UNIT WORKS WELL,BUT CAN'T KEEP 1900SQFT 1960s ... A: Bruce: So there was a 3 ton unit and you replaced it with 3-1/2 tons, right? 1,900 SF/ 3.5 Tons = ...
|
| refrigerant escaped from a/c. | 7/12/2009 | john t. borgman |
Q: We have separate Command a/c for 1300 sq. ft. condo unit in South Florida, built 1991. Responding to ... A: Mel, Did He show you the leak? A coil leak be it indoor or out, can easily be repaired. I have ...
|
| AC fan stay son after AC is off | 7/12/2009 | Jim Barnhart |
Q: Replaced an old t-stat recently with a new programmable t-stat (ritetemp model 6025). Initially had ... A: Kevin, First of all it doesn't make any difference in how something operates because of the color of ...
|
| AC fan stays on after AC is off | 7/12/2009 | Howard Livingston |
Q: Replaced an old t-stat recently with a new programmable t-stat (ritetemp model 6025). Initially had ... A: The O is not to be connected to O. Is this a heat pump ? Doesn't seem to be. The white is for heat, ...
|
| AC fan stays on when AC is off | 7/12/2009 | john t. borgman |
Q: Replaced an old t-stat recently with a new programmable t-stat (ritetemp model 6025). Initially had ... A: Kevin, http://www.ritetemp-thermostats.com/6025.html Unless there is a program set up for the fan ...
|
| Goodman AC fan stays on | 7/12/2009 | Bill Brainard |
Q: Replaced an old t-stat recently with a new programmable t-stat (ritetemp model 6025). Initially had ... A: What do you mean "On A/C"? The hook ups belong inside the furnace. The Red wire looks wrong. Here ...
|
| Home A/C unit overheating | 7/12/2009 | Craig HVAC Expert |
Q: my home HVAC unit (carrier) is having an issue. if I have the A/C unit shutdown for serveral hours ... A: Causes for compressor overheating. Poor refrigerant charge (slugging or short on charge) Dirty ...
|
| air conditioner | 7/12/2009 | Jim Barnhart |
Q: I just updated my air conditioner which was servicing the first floor and the basement from a 1.5 to ... A: Elizabeth, I'm not sure what the problem is? Is the "pump" a unit that is maybe sitting on the floor ...
|
| condensate dripping | 7/12/2009 | Jim Barnhart |
Q: The coil in my residential heat pump is at an angle, and instead of the water running down the coil ... A: Steve, I don't have a service manual on your air handler, I don't know the type either, even if I ...
|
| Oil coating inside refrigerant pipes | 7/12/2009 | Craig HVAC Expert |
Q: Here in Australia a company offers a one time service to remove the coating of oil inside pipes, ... A: There is a constant flow of oil mixed in with the refrigerant. Unless there is a burn out or some ...
|
| some rooms aren't cool or warm | 7/12/2009 | Craig HVAC Expert |
Q: My house is approx. 9 years old. I have a central heat and air unit. It does a good job of heating ... A: If you are willing to spend the money, you need to have a test and balance company out to check ...
|
| 5 ton condenser unit | 7/12/2009 | Norval Trimborn |
Q: i just replaced a 5 ton condenser unit that was grounded out and now my new one went out.What could ... A: How long after the condensing unit was replaced did this problem appear? It is possible that when ...
|
| A/C Question - Goodman CK-42-1B | 7/12/2009 | Howard Livingston |
Q: when that satisfying sound of the compressor springing to life stopped happening and just the fan ... A: nice to have good info like yours. Need to test the run capacitor for the compressor first.May be a ...
|