Expertise Answer questions pertaining to Residential and Commercial Air Conditioning and Heat Pump systems. Mechanical and Electrical troubleshooting of these units.Be as detailed as possible when describing problem.Packaged unit vs split systems.Give age of eqiuptment.And what type of heat,Heat Pump,Oil, Gas ,or Electric.
Experience 35 years experience, diversified HVAC/R . Installation and Troubleshooting, Mechanical and Electrical, in following areas, Refrigeration( Walk in and Reach in Coolers and Freezers )Commercial Roof Top and Packaged Heating/Cooling ( Natural Gas,Propane, Electric, and Heat Pumps ) Computer Room Air Conditoning Systems,Commercial Chilled Water Air Handlers and Recipercating Compressors. Residential Packaged and Split Systems Air Conditoning and Heat Pumps.Warm Air Oil and Natural and Propane Gas Heating systems.
Education/Credentials Graduated from Private Technical School in 1975.Presently an HVAC/Refrigeration Contractor. Have Unlimited Heating/Piping and Cooling Contractor License.Limited Sheetmetal Contractors License.NATE Certifield. York Certifield Heat Pumps in 1981. Served 33 years combination Active Duty Air Force ,
Air Force Reserves and Air National Guard in the HVAC/Refrigeration Shop.Starting as a Apprentice then Technician troubleshooting/installing HVAC/Refrigeration Equiptment Worldwide. Retiring in 2003 as a Mechanical Superintendent.
Awards and Honors I got many atta boy awards over the years
| | |
| |
You are here: Experts > Home/Garden > Home Appliances > Heating, Air Conditioning, Fridge, HVAC > Goodman AR32
Expert: Joe - 10/30/2009
Question I have a Goodman AR32 that was installed 3 years ago. The Coil has failed. Leaks. The system had a 2 ton and I would like to replace the coil and install a 3 ton Heatpump. The data sheets I have found on the Internet shows it could be use in several configurations. I have the coil number for a 2.5 ton. Do I have to change to coil or just the orifice that came with the goodman heatpump.(3 ton)
Answer Stephen,
Lets see you want to stuff a 2.5 ton coil inside a 2 ton air handler and match to a 3 ton condensing outdoor unit. Your too small on the indoor coil would need a 3 ton indoor unit. Also who is to say your duct work is rated for 3 tons, you have a 2 ton now. What ever happened to a warranty ?? Goodman has a 10 year product warranty on their units. Unless you bought it via Internet company, then Goodman does not warranty their units but certainly the Company where you bought it from should have given you some sort of warranty. Also Goodman web site recommends you run 7/8" OD interconnecting tubing,for a 3 ton unit, guessing you have either 5/8" or 3/4" .you probably have the liquid line of 3/8 " correct.Not to mention your blower motor/squirrel cage is rated for 2 tons. Big mismatch system your asking for.