More Heating, Air Conditioning, Fridge, HVAC Answers
Question Library
Ask a question about Heating, Air Conditioning, Fridge, HVAC
Volunteer
Experts of the Month
Expert Login
Awards
About Us
Tell friends
Link to Us
Disclaimer
|
| |
|
|
| |
| | | |
About Joe
Expertise Answer questions pertaining to Residential and Commercial Air Conditioning and Heat Pump systems. Mechanical and Electrical troubleshooting of these units.Be as detailed as possible when describing problem.Packaged unit vs split systems.Give age of eqiuptment.And what type of heat,Heat Pump,Oil, Gas ,or Electric.
Experience 35 years experience, diversified HVAC/R . Installation and Troubleshooting, Mechanical and Electrical, in following areas, Refrigeration( Walk in and Reach in Coolers and Freezers )Commercial Roof Top and Packaged Heating/Cooling ( Natural Gas,Propane, Electric, and Heat Pumps ) Computer Room Air Conditoning Systems,Commercial Chilled Water Air Handlers and Recipercating Compressors. Residential Packaged and Split Systems Air Conditoning and Heat Pumps.Warm Air Oil and Natural and Propane Gas Heating systems.
Education/Credentials Graduated from Private Technical School in 1975.Presently an HVAC/Refrigeration Contractor. Have Unlimited Heating/Piping and Cooling Contractor License.Limited Sheetmetal Contractors License.NATE Certifield. York Certifield Heat Pumps in 1981. Served 33 years combination Active Duty Air Force ,
Air Force Reserves and Air National Guard in the HVAC/Refrigeration Shop.Starting as a Apprentice then Technician troubleshooting/installing HVAC/Refrigeration Equiptment Worldwide. Retiring in 2003 as a Mechanical Superintendent.
Awards and Honors I got many atta boy awards over the years
| | |
| |
You are here: Experts > Home/Garden > Home Appliances > Heating, Air Conditioning, Fridge, HVAC > ac and furnace blower
Expert: Joe - 11/7/2009
Question i have a nordyne heating furnace and the blower motor continue to run in off position or auto the only way to turn of blower is to turn of circuit breaker to unit.need help.i have a nordyne furnace model e2e88 012ha
Answer Martha,
you don't say how old unit is.One possibility is that the fan relay contacts point welded shut and keeping your blower running 24/7.they work on time .Time on time off ( TDR ) on wiring diagram.You would need to look at the wiring diagram and trace out the blower motor leads and pull the wire off the fan relay or you may have a control board that starts the fan. Hopefully that should stop your fan.If you have the old style fan control combo limit control which mounts on the panel and has a sensor that senses heat exchanger temps. your settings may be out of calibration and not shutting the fan off due to age. your wiring diagram will tell you volumes . If you feel your blower motor is turning at half speed ,then chances you have a grounded motor.Would need to ohm out motor and check to ground.All this sounds Greek to you ,and you don't have anyone who is electrically inclined ,recommend calling for service
Joe