first the gas company turned off my gas on accident.would that effect the valve? I turn on the heat the draft blower starts,the vacuum switch works and showing 12v but the igniter does not glow gas valve does not open.I have 12v at valve,checking power from valve for igniter one had 12v other 0.there is an on off switch on the gas valve. when turning on and off I neither hear or feel the valve open. does the valve energize the other blue wire to igniter.
honeywell valve sv9501m2718

Answer
Sorry for the delay, for some reason this service is not sending me emails.

The valve needs 24v to work.  If you only have 12v, then that is why it is not working.  You need to check the transformer to see that it is putting out 24v.  You might have a low pressure switch that has to be reset due to the gas being turned off.

Craig

Heating, Air Conditioning, Fridge, HVAC

All Answers


Answers by Expert:


Ask Experts

Volunteer


Craig HVAC Expert

Expertise

I have been in the HVAC field for the past 18 years. I can help with most HVAC questions. I work on commerical buildings for the most part, and have yet to find anything I could not troubleshoot and repair, when repairable. I work on small 1 ton units to a 2500 ton chiller. Troubleshoot air flow, elect, and control problems. I attend regular classes to keep up with the latest and greatest.

Experience

I work on commerical sites, hospitals, gov't buildings. I can troubleshoot just about anything in the HVAC business.

Education/Credentials
5 years trade school, VFD training classes, Liebert factory training, some York and Trane factory training.

©2016 About.com. All rights reserved.