Heating, Air Conditioning, Fridge, HVAC/Fan cycling

Advertisement


Question
Should the outside fan on a Rheem RAKA-024JAZ cycle on and off, I just replaced the fan and cap and fan was running but shut off but compressor was still running the outside temp is supposedly 74 degrees but feels a lot cooler than that to me!  Thanks for your help

Answer
Marty,

As long as your t-stat is calling for cooling, your compressor and outdoor fan runs together , if your outdoor fan shuts off ,the refrigerant pressures will increase very high, and hopefully your outdoor unit should shut off at the high pressure switch, before damage occurs. ( hopefully your unit has a HPS )  if your a DIYer you may have the motor wired wrong or it's not the same size as the original horsepower rating, or amprege rating, or your fan is turning backwards. Something is not right . A lot of replacement motors are reversible.  

Heating, Air Conditioning, Fridge, HVAC

All Answers


Answers by Expert:


Ask Experts

Volunteer


Joe

Expertise

40+ years diversified experience.An HVAC/Refrigeration Self Employed Contractor since 1986. NATE Certifield. Answer questions pertaining to Residential and Commercial Air Conditioning , Warm Air Heating, Heat Pump systems.Mechanical and Electrical troubleshooting of these systems.Be as detailed as possible when describing problem.Packaged unit or split systems.No appliance questions.

Experience

Installation and Troubleshooting, Mechanical and Electrical, in following areas, Refrigeration ( Walk In and Reach In Coolers and Freezers ) Commercial Roof Top and Packaged Heating/Cooling ( Natural Gas,Propane, Electric, and Heat Pumps ) Computer Room Air Conditoning Systems,Commercial Residential Packaged and Split Systems Air Conditoning and Heat Pumps.Warm Air Oil , Natural and Propane Gas Heating systems.

Education/Credentials
Graduated from Private Technical School in 1975. An HVAC/Refrigeration Contractor . Have Unlimited Heating/Piping and Cooling Contractor License.Limited Sheetmetal Contractors License.NATE Certifield. York Certifield Master Heat Pump Technician 1986. Served 33 years combination Active Duty Air Force , Air Force Reserves and Air National Guard in the HVAC/Refrigeration Shop/Mechanical Shop. Troubleshooting/Installing HVAC/Refrigeration Equiptment Worldwide. Retiring in 2003 as a Senior NCO ,and a Mechanical Superintendent.