Heating, Air Conditioning, Fridge, HVAC/2-Year-Old Trane XR15- No Sound/Movement Outside


Dear Joe,
Thank you for sharing your expertise on this site. I use it often, and I appreciate all of you experts, volunteering.

I have a 2-year-old TRANE XR15 that has worked fine all winter, but it will not cool.
The unit outside seems to be dead - no noise or movement. I can hear the unit power on in the house.

It is Sunday evening and hot in Louisiana. I will call the sales rep tomorrow, but I would like to know if there is anything I can do tonight.


First thing to check is the circuit breaker for the outdoor unit located at your breaker panel , your not sure if it tripped turn it off then back on . Hopefully they marked the breaker for you. Depending on how long your labor warranty is for it may not cost you anything. If the breaker looks OK ,then possible one of your fuses outside at the shut off switch that feeds the outdoor unit . They make two types of outdoor disconnect switch ones with fuses and ones without fuses . So if you have a non fused disconnect/ shut off switch , that would be one less problem. Lastly if you lost your refrigerant charge due to a leak , since you used it last , the low pressure switch will open and keep your outdoor unit off. I assume your indoor fan section unit is working ?  

Heating, Air Conditioning, Fridge, HVAC

All Answers

Answers by Expert:

Ask Experts




40+ years diversified experience.An HVAC/Refrigeration Self Employed Contractor since 1986. NATE Certifield. Answer questions pertaining to Residential and Commercial Air Conditioning , Warm Air Heating, Heat Pump systems.Mechanical and Electrical troubleshooting of these systems.Be as detailed as possible when describing problem.Packaged unit or split systems.No appliance questions.


Installation and Troubleshooting, Mechanical and Electrical, in following areas, Refrigeration ( Walk In and Reach In Coolers and Freezers ) Commercial Roof Top and Packaged Heating/Cooling ( Natural Gas,Propane, Electric, and Heat Pumps ) Computer Room Air Conditoning Systems,Commercial Residential Packaged and Split Systems Air Conditoning and Heat Pumps.Warm Air Oil , Natural and Propane Gas Heating systems.

Graduated from Private Technical School in 1975. An HVAC/Refrigeration Contractor . Have Unlimited Heating/Piping and Cooling Contractor License.Limited Sheetmetal Contractors License.NATE Certifield. York Certifield Master Heat Pump Technician 1986. Served 33 years combination Active Duty Air Force , Air Force Reserves and Air National Guard in the HVAC/Refrigeration Shop/Mechanical Shop. Troubleshooting/Installing HVAC/Refrigeration Equiptment Worldwide. Retiring in 2003 as a Senior NCO ,and a Mechanical Superintendent.