AllExperts > Heating, Air Conditioning, Fridge, HVAC 
Search      
Heating, Air Conditioning, Fridge, HVAC
Volunteer
Answers to thousands of questions
 Home · More Heating, Air Conditioning, Fridge, HVAC Questions · Question Library  · Free Encyclopedia ·
More Heating, Air Conditioning, Fridge, HVAC Answers
Question Library

Ask a question about Heating, Air Conditioning, Fridge, HVAC
Volunteer
Experts of the Month
Expert Login

Awards

About Us
Tell friends
Link to Us
Disclaimer

 
 
 
About Norval Trimborn
(Top Expert on this page)

Expertise
Residential and light commercial HVAC questions

Experience
40 years of HVAC Service

Organizations
Refrigeration Service Engineers Society

Education/Credentials
HVAC Certificate, Trane Comfort Specialist, NATE certified Heat Pump Technician

   

You are here:  Experts > Home/Garden > Home Appliances > Heating, Air Conditioning, Fridge, HVAC

Questions Answered By Expert  Norval Trimborn 
In Category  Heating, Air Conditioning, Fridge, HVAC

SubjectDate Asked

Gas valve wont open11/18/2009
  Q: I have a Trane XE 70 that won't heat. The gas supply is good, and the electronic ignition is coming ...
  A: Check at the plug that goes into the gas valve with wires attached to it to see if you have 24 volts ...
Heat Pump Pressures11/15/2009
  Q: How can you determine if the compressor valve is bad or it's the reversing valve that is not ...
  A: Run the system and disable the condenser fan motor while the system is running(the blower motor in ...
humidistat setting11/11/2009
  Q: My home always feels damp and warm. Have not had a humidistat for long time and in our new place it ...
  A: The humidifier is not normally used at the same time as the A/C. The A/C is taking humidity out of ...
Split AC unit with Freon leak11/10/2009
  Q: I have a split HVAC unit. It is a Goodman 4-ton, 12-seer unit. I recently had the dye test done to ...
  A: That seems a little early in the systems life to develop a leak. I would ask exactly where the leak ...
Wiring of a Condensate Pump to my System11/6/2009
  Q: I have a question regarding the wiring of a safety switch of a condensate pump to my residential ...
  A: If the pump must work both summer and winter you would have to break the "R" wire with the safety ...
Heat will not operate in auto fan mode11/5/2009
  Q: I have central air with "strip heat" in my home. I replaced my old thermostat with a new ...
  A: There is normally either a switch(physical) inside the thermostat or a setup option(programming) to ...
Replacing T-Stat11/3/2009
  Q: I have a White-Rodgers 2 stage heat pump/AC thermostat (#0745T) (cannot set temperature to be ...
  A: Yes you would need a heat pump capable thermostat. With only 4 wires to the t-stat you are not ...
heater11/2/2009
  Q: Norval Trimborn, I have a Trane XR 80 forced air furnace about 7 years old. The problem with it ...
  A: An open high limit can be from a previous cycle of the furnace. This can be due to overheating from ...
damper assembly installation10/31/2009
  Q: I've been told by an HAC guy that my upstairs zone damper assembly needs to be replaced. The ...
  A: Although the cost may seem high compared to the "internet" price of the part you must realize that ...
mold on coils10/29/2009
  Q: I just had my furnace cleaned. My house is only four years old and the service man said and showed ...
  A: Yes, the moist environment by the A coil can promote the growth of mold and bacteria. The use of UV ...
gas furnace10/29/2009
  Q: My furnace works very well when it comes on. I have to push the reset button on the furnace sometime ...
  A: It depends on which reset button you are pushing(vent safety or rollout switch ). In either case you ...
Residential Outside condenser.10/28/2009
  Q: Our 4 ton consendser went out. We had a service tech come out and he diagnosed that the compressor ...
  A: The 4 yr. old coil should not need to be replaced. The oil and refrigerant in the system will have ...
payne furnace10/24/2009
  Q: my furnace is displaying a code 33 signal. this model does not have a flame rollover reset. i am ...
  A: Carrier 33 fault code is for a limit fault(high limit, rollout etc.). The device with the 2 red ...
Furnace Exhaust10/22/2009
  Q: Situation:I live in Canada, Southwestern Ontario,. I have a Armstrong HE furnace about 3 years old. ...
  A: Installation guides normally dictate that the vent termination must be at least 12" above the snow ...
Heating unit not heating10/20/2009
  Q: I have a ducane unit that is about 4 years old and have had a few problems with it not heating at ...
  A: It sounds as if you might have a heat pump from your description. What were your previous problems ...
old jenitrol furnace blower10/19/2009
  Q: My heating works and the blower comes on, but the blower will not shut down when furnace turns off ...
  A: On older furnaces the blower was turned on by a helical bimetal fan/limit switch in the heat mode. ...
Flame Sensor10/19/2009
  Q: I have a Snyder General furnace, Model GUI100A016IN, Serial #R910500537. This thing chews through ...
  A: It isn't normal for a flame sensor to need to be replaced more than once a year or even yearly. They ...
12 year old furnace broke - fix or replace?10/17/2009
  Q: our 12 year old ICP/Keepright gas high efficiency furnace broke. The gas valve is defective and the ...
  A: Although parts can last longer than 10-12 yrs. there is also a good chance that you can have 1 or ...
12 year old furnace broke - fix or replace?10/17/2009
  Q: our 12 year old ICP/Keepright gas high efficiency furnace broke. The gas valve is defective and the ...
  A: You need to know why the 12 yr. old heat exchanger failed. Manufacturing defect (some keepright ...
Upgrade from 92-95% and adding variable valve/speed-Worth it?10/16/2009
  Q: I currently have TWO 80% 20 year old Tempstar 150K BTU furnaces, one for each floor in my 4600 sq ft ...
  A: It's a little tough to estimate the portion of your gas bill that is due to the furnaces as they are ...
pilot light10/16/2009
  Q: I'm trying to light my pilot for the first time this year. My nephew usually does this for me. It ...
  A: Yes , you need to hold down the red button on the gas valve with the gas valve selector/dial in the ...
Trane A/C9/19/2009
  Q: I am the president of an association that has a large trane a/c system less than 10 years old. We ...
  A: Your rooftop package unit is probably going off on the high pressure safety(and holding relay which ...
3 part question9/18/2009
  Q: Can a clogged freon line cause the inside unit to leak? If a tech has to add freon when the unit is ...
  A: A system that runs with the freon low will damage the compressor. There is a good chance that the ...
4-ton A/c condenser replacement9/17/2009
  Q: Trimborn: We need to replace our 4-ton residential Lennox A/C condenser. We will be using a ...
  A: I am partial to both Trane and Carrier as brands. You have a wide range of options with either ...
Air Conditioning & Thermostat9/13/2009
  Q: My a/c unit does not shut off when the thermostat does. We replaced the square 0 2 pole 60 Amp 240 ...
  A: It sounds as if you have a heat pump from the number of wires that you have to the thermostat. ...
residential hvac9/12/2009
  Q: I just replaced the thermostat for my residential hvac system (gas heat, std hvac). I didn't turn ...
  A: You need to check and see if the condensing unit contactor is pulled in with or without 24 volts to ...
New AC unit not cooling enough9/10/2009
  Q: I live near Tampa Fl. We puchased a new 3 ton central ac unit for our 1585 sq ft house. When it's ...
  A: A 3 ton system is a 3 ton system. If operating properly the new unit should cool as well as the old ...
water overflow from evaporator9/10/2009
  Q: We are having a problem with water over flowing from our carrier a/c unit. We have checked the pipe ...
  A: When the drain line was plugged up, the water would have filled the evaporator condensate pan and ...
Plenum question9/9/2009
  Q: Greetings from MN, I recently had a new outside AC unit replaced as well as the coil inside my ...
  A: Yes, the ugly putty is the norm for sealing the lines as they go through the plenum. It can be done ...
Rheem not blowing cool air9/7/2009
  Q: My Rheem a/c is approximately 4 1/2 years old. It suddenly stopped blowing cool air and I don't ...
  A: The handle in the service disconnect (that says on/off) is a pullout to interrupt power(240 volts) ...
Replace A/C evaporator coil or get new unit9/5/2009
  Q: I have a 15 yr townhouse in CA and the original A/C unit in the attic has apparently been leaking ...
  A: At 15 yrs. your system would be considered well past middle age. R22 coils are still available until ...
no power - not breaker9/5/2009
  Q: I have no power to either the inside or outside units when I switch the thermostat. I hear the ...
  A: Did you check for power with a volt meter? If so you will need to check from the unit(s) back toward ...
A/c fan inside will not come on9/5/2009
  Q: I have an old whirlpool/Honeywell patched together HVAC unit in closet. bout 15-20 yrs. No computer ...
  A: You might be trying to use a relay with a 240 volt coil when you should have a relay with a 24 volt ...
Nordyne blower for AC unit9/4/2009
  Q: and we went up into the attic where the heater blower is. It's a Nordyne model#FG6RA 072C-12A. The ...
  A: Is the fan motor in the attic unit running? If it is and the system is iced up it is usually due to ...
Freon Leak Detection cost8/30/2009
  Q: I had regular maintenance scheduled and was told that my freon was low(our unit uses R22 freon). I ...
  A: Did you at least get a copy of the maintenance agreement that you signed up for? You should be able ...
freezer compressor8/29/2009
  Q: Norval, I realize this question may be off the beaten track but thought you might know the answer ...
  A: I haven't done any refrigeration in more than 30 yrs.. A lot depends on what the compressor failure ...
purchasing new furnice8/29/2009
  Q: Our home is bi-level. 2,400 sq. ft. We are going to be purchasing a new furnice. I say we replace ...
  A: For information on which furnaces and air conditioners qualify for a tax credit go ...
AC fan motor works intermittently8/28/2009
  Q: I have a Carrier AC system. The compressor works fine, but the AC fan is working intermittently. ...
  A: I am assuming that you are talking about the outdoor fan motor. It could be the motor itself or the ...
Heat Pump Layout8/27/2009
  Q: Norv, Probably dont' get questions like this very often. My a/c exterior condensor fan went out a ...
  A: In straight AC operation the outside coil rejects heat and the inside coil absorbs heat. In a heat ...
Trane 1000xb not cooling8/27/2009
  Q: I just bought a house that was built in 2000 we have a trane AC unit out back. My outdoor unit ...
  A: It sounds like you have a problem with the condenser fan motor. It may be either the motor itself or ...
Basement hating question8/27/2009
  Q: I have a 6 year old 2,400 sq ft ranch with a basement with 1,400 sq ft finished. I have ceiling ...
  A: Do you leave the stairway to the basement open or is there no door to the basement stairway? If ...
evaporation coil8/25/2009
  Q: Our A/C unit is only 4 yrs old and we had to call a service company today to have it checked because ...
  A: $1157.00 labor to replace an evaporator coil that is under warranty is WAY out of line! You might be ...
copper piping leak?8/24/2009
  Q: My house was built in 2003 and it had a Carrier (4 ton, 10 seer I believe). The outside unit was ...
  A: It is not normal to have to replace a six year old system(it should have a much longer lifespan). ...
Bad compressor in o/s condensor unit of heat pump8/23/2009
  Q: I'm in east central PA. I've had to repl compressors 3 times in the 22 yrs I've had this heat pump. ...
  A: It sounds as if you may have a shorted/grounded compressor. Bad compressor doesn't mean ...
replacement HVAC system8/23/2009
  Q: We are replacing our 15 year old split A/C and gas furnace as the E coil is leaking Freon and cannot ...
  A: Although the information that you have given is fairly thorough it is still difficult to tell ...
Capacitor Blown8/22/2009
  Q: My a/c recently stopped working, after some investigation i discovered the outside unit fan doesn't ...
  A: When you say that the capacitor was blown, do you mean that the outside casing of the capacitor was ...
410A Pressure Temerature Chart Conversions8/22/2009
  Q: I have a technical question about 410A and pressure temperature charts and i really need some help. ...
  A: The old ambient plus 30 degrees only applied to old low SEER systems and then was only an ...
Freon Leak Detection cost8/20/2009
  Q: I had regular maintenance scheduled and was told that my freon was low(our unit uses R22 freon). I ...
  A: Did the service technician ask you if you wanted to have the system leak checked before he put the ...
new burner or boiler8/20/2009
  Q: Our Wisconsin church has a 40 yr old non-condensing hot water boiler heating system. The boiler ...
  A: Condensing/noncondensing refers to whether or not enough heat is removed from the products of ...
new burner or boiler8/19/2009
  Q: Our Wisconsin church has a 40 yr old non-condensing hot water boiler heating system. The boiler ...
  A: You don't mention much about the building/piping layout and usage. Church only, church and offices ...
residential high-efficiency fans8/18/2009
  Q: What is the cost difference between a high efficiency fan and a standard fan for residential HVAC ...
  A: A continuously variable speed DC motor is more expensive initially than a standard blower motor, but ...
Amana furnace problem8/17/2009
  Q: We have an Amana furnace that is about 7 yrs old and isn’t working. We had our vents cleaned last ...
  A: Most newer furnaces have an automobile style 3 or 5 amp low voltage fuse on the circuit board in the ...
aircondotion/heating8/17/2009
  Q: I have a twop storied houise served by one centtral unit. the problem is that the 2nd floor is so ...
  A: Putting the fan in the "on" position instead of the "auto" at the thermostat may help some. If you ...
heater ignitor8/17/2009
  Q: I have a question regarding my heater, how I could change the furnace ignitor? by the way I am a ...
  A: Is it a hot surface ignitor? There are 2 types. Silicon carbide ignitors have a ...
home ac8/16/2009
  Q: my home ac unit seems to run alot and have a hard time cooling the house down. i have cleaned my ...
  A: Do you have an upflow furnace in the basement, a downflow in a closet/laundry room or a horizontal ...
central a/c8/15/2009
  Q: Trimborn. The air coming out of the vents is very low so I called a tech. During the inspection he ...
  A: An 8 yr. old system should still have many years of life left in it. If this is the first time that ...
NEW FAN MOTOR8/14/2009
  Q: My HVAC units fan motor had to be replaced. I pulled the old motor, while taking photos of the ...
  A: It sounds like you you don't have the correct replacement motor. The old motor sounds like a single ...
central a/c8/14/2009
  Q: Trimborn. The air coming out of the vents is very low so I called a tech. During the inspection he ...
  A: How old is your system? That can make a lot of difference. Some leaks are repairable and some aren't ...
New Blower Motor Barely Turns8/14/2009
  Q: I have a 10-12 year old Tempstar PGF018K040A package gas/electric unit. The blower stopped working ...
  A: Check the voltage supplied to the motor when the motor is running. It should match the voltage on ...
Central Air8/13/2009
  Q: We are currently experiencing no air flow in our home. The outside fan is moving and there is no ice ...
  A: If the filter has gotten plugged up in the past the air can't go through it, so it goes around ...
high velocity system8/12/2009
  Q: I have a 1 year old 3.5 ton system that isnt cooling my house consistently. I have the tstat set at ...
  A: Was it just for a clean and check the last time the tech was out? 74 degrees doesn't sound like an ...
extended warranty8/11/2009
  Q: I am going to have a Trane xr15 system installed in my 1752 sq ft house in Fl. Does it pay to get ...
  A: If you are referring to the extended warranty through Trane, I would consider it a good value for ...
blower fan8/8/2009
  Q: My AC blower fan starts then stops, I've replaced the run capacitor, and sometime it works for a few ...
  A: If the blower motor stops while you still have full voltage supplied to it, the problem would seem ...
dog chewed wires on central air unti8/7/2009
  Q: Ok, I came home from work to find my house hot! The furnace unit in the house was running but not ...
  A: If you reattached the wires outside while the AC was still supposed to be running you may have ...
cleaning condenser coils8/7/2009
  Q: is there a best practice for cleaning a/c condenser coils on comeercial RTU's ANSWER: Some ...
  A: The amp. draw on a propeller style blade fan motor will increase if it is starved for air, so if you ...
cleaning condenser coils8/6/2009
  Q: is there a best practice for cleaning a/c condenser coils on comeercial RTU's
  A: Some commercial rtu's have split condenser coils and the top of the units must be taken off in order ...
TOO HOT IN MY HOUSE.8/6/2009
  Q: HOW DO YOU KNOW IF MY A/C UNIT IS FULLY CHARGED? MY UNIT RUNS CONSTANTLY AND HOUSE WILL GET UP TO ...
  A: The air coming out of the supply registers is normally 18-20 degrees cooler than the air coming into ...
Trane XL12008/4/2009
  Q: This is a brief history of the questions asked previously. I have a TRANE XL 1200 Super ...
  A: Difficult to say. A grounded compressor should trip the breaker right away, yet you said that the ...
New compressor and still not cooling8/4/2009
  Q: My outside unit stopped working, it is a Rheem from 2002 unit. The repairman changed the compressor. ...
  A: Was the compressor failure a burnout or a mechanical failure? Most early compressor failures are due ...
HVAC coil8/4/2009
  Q: I live in Florida. The house I bought was completed in 06-2000, with an installed Trane TWE042 ...
  A: Most(but not all) early compressor failures are due to improper installation procedures or ...
AC CONDENSATE8/3/2009
  Q: I recently noticed water dripping from the "REFLECTIX" insulation that covers the AC coil and duct ...
  A: A 5 year old drain pan should not be cracked, but it is possible. If the evaporator coil has become ...
Indoor Humidity Issue8/3/2009
  Q: First off I live in Central Florida. It is very hot and humid right now, and also raining heavy ...
  A: Stumping me too unless the humidity is much higher than before or you have developed a way for more ...
Indoor Humidity Issue8/2/2009
  Q: First off I live in Central Florida. It is very hot and humid right now, and also raining heavy ...
  A: I am assuming that you have made sure that the cond. coil, evap. coil and blower wheel were all ...
Coli Cleaning8/2/2009
  Q: I just received an assessment of my 15-yr old Heil 5000 unit from an Admiral "freon-charging ...
  A: The price for cleaning the coil seems excessive unless the only way to clean the coil is to pump ...
Size of plenum on residential a/c unit8/2/2009
  Q: I recently hired a company to conduct a yearly inspection/cleaning on my residential central air ...
  A: Has the system been working fine for the last 4 yrs. until recently? If so the problem would more ...
Air Cleaner8/1/2009
  Q: Okay, so I am really confused. What I thought would be a simple purchase has completely complexed ...
  A: Electrostatic filters tend to be very restrictive to airflow(not good). Media filters tend to be ...
Duct Work but No Compressor8/1/2009
  Q: My husband and I purchased a house 12 years ago. The house was built in 1985. It appears to have ...
  A: If your ductwork has been designed for heating only it will probably be inadequate for a cooling ...
Heat Pump not working in AC mode7/31/2009
  Q: I live in CT and have a heat pump system that is approx 15 years old. When the system runs in the ...
  A: In cooling mode the large copper pipe between the outdoor and indoor unit should be cold. In heating ...
problem with air & ins. coverage7/29/2009
  Q: Just moved in to a new house and purchased American Home Shield home warranty (AHS)in escrow. After ...
  A: Yes you can replace the furnace without replacing the condensing unit or coil. Your coverage under ...
Kickstart / Dual Capacitor (45/5)7/29/2009
  Q: I just had an AC repair (Amana 14 seer)4 ton or 5 ton unit. The tech came & installed a 45/5 Dual ...
  A: Mark ups are high in this business. Technicians, office personnel, physical plant, vehicles and ...
Connecting wiring for electronic air filter7/28/2009
  Q: I have a Dynamic electronic air filter. I say's to connect the two wires to R and C. I understand R ...
  A: The 4 wire run from the t-stat connects to R,W1,G and Y. The 2 wire run from the outside AC ...
HVAC Theory7/28/2009
  Q: I recently had an Amana 3 ton ASX16 16 SEER HVAC system with gas heat installed in my house in ...
  A: It sounds as if you have a variable speed DC motor for the blower. The correct setting for a 3 ton ...
HVAC Theory7/27/2009
  Q: I recently had an Amana 3 ton ASX16 16 SEER HVAC system with gas heat installed in my house in ...
  A: Older systems with a fixed metering device feeding the evaporator coil did not throttle down the ...
compressor delay7/27/2009
  Q: NOT ALL THE TIME BUT ONCE IN AWHILE MY O/S UNIT STARTS WITH THE FAN ONLY THEN AFTER ABOUT A MINUTE ...
  A: Both the compressor and the condenser fan motor are powered through the contactor. They should both ...
air conditioning argument7/26/2009
  Q: "My father (88) and I (62) have a running disagreement about how to run the air conditioner in our ...
  A: Economically it is better to open the windows if there is enough circulation in the house when it is ...
compressor delay7/26/2009
  Q: NOT ALL THE TIME BUT ONCE IN AWHILE MY O/S UNIT STARTS WITH THE FAN ONLY THEN AFTER ABOUT A MINUTE ...
  A: There should be no delay for the compressor starting. If it is an older unit you may benefit from a ...
Trane XB 1000 Bad Compressor7/23/2009
  Q: I was having a problem with my ac unit not cooling down my house. As the temperature rose ...
  A: 100 PSI on the suction side is a high reading and 160PSI on the high side is a low reading. A 100 ...
replacing freon in a 5 ton compressor7/23/2009
  Q: THe repair man who is installing new compressor in my 3 year old Carrier unit tells me the freon ...
  A: The freon in the system must be removed in order to replace the compressor. What was the problem ...
removimg a gas furnace7/23/2009
  Q: I need to remove a furnace and cap off a gas line in order to have a heat pump/air conditioning unit ...
  A: It sounds like your taking all the precautions that you should. Once the pressure is off the gas ...
Kenmore gas water heater Power Miser 97/22/2009
  Q: Main burner ignites and burns maybe 5 minutes. when it shuts down the pilot goes out with it. I ...
  A: Water heaters aren't my specialty, but years ago when HVAC techs did service water heaters I ran ...
AHU Variable Speed7/20/2009
  Q: I recently had a new Goodman 4 ton system installed and the AHU has a variable speed fan. The ...
  A: On many variable speed units the default blower speed for the fan ON setting at the t-stat is 25-50% ...
HVAC Problem7/19/2009
  Q: I have a rheem HVAC, Out of a 100 start ups once it want'ts to start but i only hear a suction or ...
  A: How old is your system? Adding a hard start kit to an older system(or even a new one that didn't ...
airconditioning/heating7/19/2009
  Q: My office is at the far end of the house and it is freezing in the summer and too warm in the ...
  A: Normally there is a damper at the point that each supply takeoff comes off the main supply trunk. ...
Carrier 38BRB - adding R-227/18/2009
  Q: Do you know if the Carrier 38BRB can with back seated valves - even though I do see a schrader valve ...
  A: I am not familiar with that specific model of Carrier. Most of the Carrier cond. units I have seen ...
Condenser motor Noise7/18/2009
  Q: AC makes horrible noise when running, pinpointed noise to condenser motor. Sprayed some lubricant on ...
  A: If it hasn't been oiled regularly you may be past the point of oiling doing any good on a permanent ...
MEASUREMENTS7/18/2009
  Q: first it seems like my t-stat when i change something is turns off and then maybe turn back on, like ...
  A: With the t-stat set to OFF you should read 24 volts from the R terminal on the t-stat to all other ...
Central air conditioning unit7/17/2009
  Q: I live in southern Louisiana and need to replace my central air conditioning unit. My home has ...
  A: That sounds a bit too large even for the Phoenix AZ area where I lived for 5 yrs.. What size is the ...
Squirl Cage Blower7/16/2009
  Q: I have a Ruud Furnace/ air conditioner system from 1879. I need to replace the blower and want to ...
  A: Goodness that's an antique(1879). The blower wheel is replaced by diameter,width and rotation(the ...
HVAC7/16/2009
  Q: I am in the process of shopping for a new centrtal AC unit but I don't have a clue of which brand is ...
  A: When you compare, it must be apples to apples. The SEER rating on the units you are comparing has to ...
AC gurgling in drain line7/16/2009
  Q: At my new home in TN. our AC man been back to service the upstairs Goodman ac/heatpump 6 times.The ...
  A: Drains on the return side of the system must be trapped. After the trap, the drain line must be ...
Honeywell RTH111/221 Thermostat7/15/2009
  Q: I am installing a Honeywell RTH111/221 thermostat to control my gas heat, ac and fan. The previous ...
  A: For normal color coding the red wire should go to RC/RH terminals on the t-stat which may be ...
Residential AC7/13/2009
  Q: AC quit blowing cold, slowly getting warmer over apx. 3 month period. Had friend come charge system, ...
  A: The evap. coil can be pressurized to 50-100 psi and then checked the next day to if it has lost a ...
A/C blowing from cold to hot with out changing....7/13/2009
  Q: My a/c will run fine for as long as 2-6months, then suddenly start acting as if it has a mind of ...
  A: It would be difficult to tell without knowing more about the system. It seems as though you are not ...
Residential AC7/12/2009
  Q: AC quit blowing cold, slowly getting warmer over apx. 3 month period. Had friend come charge system, ...
  A: Did the contractor say there was a leak in the evap. coil? If they replaced the evap. coil and had ...
5 ton condenser unit7/12/2009
  Q: i just replaced a 5 ton condenser unit that was grounded out and now my new one went out.What could ...
  A: How long after the condensing unit was replaced did this problem appear? It is possible that when ...
humidity7/10/2009
  Q: I had a 4ton straight cool which was replaced with a 3 ton heat pump - per load calculation. It ran ...
  A: With a continuously variable speed motor you should have the option to decrease the air volume from ...
air conditioner fan7/10/2009
  Q: Goodman unit, 4 years old. Stopped cooling upstairs, however I feel air going into the intake. The ...
  A: Does the compressor run in the outside unit or are both the compressor and the fan in the outside ...
installing new furnace and air conditioning7/9/2009
  Q: We are currently replacing a radiant ceiling heat system. Under options is listed "electronic air ...
  A: Electronic air cleaners do a very good job(especially if someone in the house has allergies) but ...
gas air conditioner7/9/2009
  Q: In Indiana visiting family and my moms natural gas central cooling system won't kick on. The blower ...
  A: If nothing runs outside you probably have a high or low voltage loss to the outdoor unit. You would ...
baseboard heat7/9/2009
  Q: We have a boiler with pipes that run to the baseboard heaters in all rooms. We are installing a ...
  A: If you disconnect and cap off that run you will lose all the heat that radiator produced. If you ...
AC blower turns on intermittently7/8/2009
  Q: I have a 13 year old LENNOX AC unit and some kind of builders grade blower in the Attic. The Unit ...
  A: You may have a problem with either the motor or capacitor the is causing it to shut down on internal ...
altitude spec. on a/c unit7/7/2009
  Q: Will an American Standard Triumph 16 packaged unit with a specification altitude rating of 0 - 2000 ...
  A: The altitude specification is for the gas heating side of the unit. The gas manifold orifices should ...
Freon cost $185.607/7/2009
  Q: In addition to the big annual check up fee I was charged $185.oo for four pound of Freon. The ...
  A: If you have a 3 yr. old system that needs 4 lbs. of freon, you have a leak. The technician should ...
Control circuit issues7/6/2009
  Q: I wired together yellow of the cooling circuit and blue(common) before turning off the indoor air ...
  A: What was the original problem that had you tying the wires together? If the air handler has ...
Air conditioner contracts7/5/2009
  Q: Trying to help out my elderly father down in Fla. He is asking me about getting a service contract ...
  A: Most companies these days do not write full coverage service contracts(covering cleanings and parts ...
In attic A/C leak....7/5/2009
  Q: Timborn, i have a question for you....I noticed a leak in my ceiling right where our attic A/C unit ...
  A: If its backing up into the drain pan and the drain pan is overflowing it is most likely a plugged ...
ac drip at vent7/5/2009
  Q: in an upstairs closet the vent is dripping. There is an attic access panel in that closet. I live ...
  A: You should check the whole duct branch to the register outlet to see if moisture is accumulating in ...
SEER rating7/4/2009
  Q: I've been trying to find the SEER rating of my ComfortMaker air conditioner unit. The installer ...
  A: How long the system runs depends on the outside temperature, whether everything is clean(filter, ...
air handler drain line7/4/2009
  Q: Does the drain fittings need to be glued together and can they just hook together dry? I know it ...
  A: The drain fittings should be glued, but I usually leave the upstream side of one of the horizontal ...
Turning off upstains AC7/3/2009
  Q: We have a two story home and are now empty nesters. We live in the downstairs and the upstairs is ...
  A: If you have high humidity in your area and you run only 1 of 2 units you may have trouble keeping ...
Wrong run capacitor installed?7/2/2009
  Q: Due to a lack a parts at the time, I replaced a residential dual run capacitor rated 60/3 370 volts ...
  A: Yes you should replace the 5mfd with a 3 mfd. The voltage rating is ok since you can always replace ...
Freon7/2/2009
  Q: I'm a new homeowner and would normally ask my Dad these questions, but he passed away suddenly in ...
  A: If it was very low on freon then there is a leak in the system. You need to have the system leak ...
HVAC Handler in attic7/1/2009
  Q: Sir I am in the process of buying a townhome in Freeport FL and had the home inspected. The ...
  A: The air handler in the attic should have a secondary drain pan under the unit with a float or wet ...
evap coil7/1/2009
  Q: I have a Rheem Model RCBA-2459GG14 cased evap coil, 1994 installed. Indoor unit is vertical, ...
  A: This should not be a capillary tube coil because of the install date. The distributor tubes are ...
RHEEMS Compressor failed7/1/2009
  Q: Lodi, California (it was 110F on Sunday so I am motivated) The house I purchased in 1990 has a ...
  A: Yes you can just replace the compressor. Yes a new system will cost more than just replacing the ...
airconditioner6/29/2009
  Q: I live in Houston Texas the tempature is around 100 degrees outside if i have the ac set on 70 at ...
  A: It depends on sizing practices in your area. If your area has high humidity during most of the ...
a/c question6/29/2009
  Q: i have no low voltage to yellow wire coming from the thermostat or if i test at thermosta only red ...
  A: The majority of thermostats do not have a 24v common wire to them. What are you testing the R(red) ...
Replacing outside unit of split system6/29/2009
  Q: My system is almost 20 years old. The compressor of outside unit must be replaced. Should the ...
  A: Yes the outside unit only can be replaced, but it doesn't make much sense as a 20 yr. old evaporator ...
Need a new A/C & Heater6/28/2009
  Q: It is time to get a new system. We have gas. There are various businesses out there who can give us ...
  A: Most major manufacturers equipment are all comparable. In order to compare apples to apples, "good', ...
1/2 to 3/4 hp furnace blower motor6/27/2009
  Q: and thankyou ahead of time for any helpful info. I currently have a Rheem Classic 90 Plus ...
  A: The blower motor horsepower is sized by the manufacturer for the size of the blower wheel. Since ...
Steam cleaning ac coils6/27/2009
  Q: I have access to my ac coils (condenser as I have heard it referred to) I have heard of the ...
  A: I am not sure which coils you are talking about. Condenser coils are the outside part of the system ...
Central air conditioning units6/26/2009
  Q: Norval, What is the best company (brand) to buy a central air conditioning unit from? How do you ...
  A: Any of the major brands put out good solid equipment. Trane is one of the brands that I have always ...
Bad A-Coil & Drip and and Should I Replace!6/26/2009
  Q: I recently discovered water at the bottom of my furnace after running my central air. Had service ...
  A: If you are just looking to get by until the condensing unit must be replaced then a replacement ...
AC fan shuts off6/26/2009
  Q: We have a Goodman CKL-30-1f air conditioner. We had a repairman come and he found the capacitor ...
  A: If both the old and the new motor are the same voltage, horsepower, rpm and rotation it would seem ...
Lennox HP22, cooling problem6/26/2009
  Q: I have a Lennox HP 22 Heat pump. The unit runs fine and has no out of the ordinary noises coming ...
  A: It is possible that the system is low on refrigerant. It is also possible that there is another ...
AC Usage6/25/2009
  Q: Greetings, I have a general, non-vendor specific question I was hoping you could help with. My ...
  A: Running a central air system that is working properly and is clean and has a clean filter in it does ...
Central a/c6/25/2009
  Q: If I am trying to cool my 760 sq. ft. apt to 70 degrees, what should the temp of the air that blows ...
  A: The supply air temperature should be 18-20 degrees colder than the return air at average relative ...
HVAC working no, air in vents, house not cooling6/25/2009
  Q: Trimborn, I have an HVAC unit and it seems to be working full speed, but no air is coming out of the ...
  A: Check to see if the system is icing up. This starts at the evaporator coil inside and can work its ...
New A/C Unit & Wiring Problem6/24/2009
  Q: We have a 30 yr old central air system. The a/c has been limping along for the past few years, ...
  A: Both the furnace and also the condensing unit should be dedicated electrical circuits( they should ...
saftey switch on a little giant pump6/24/2009
  Q: I am installing a little giant condensation pump on my Trane central air unit.I have 2 wires coming ...
  A: You would actually put these 2 wires in series with the "Y" connection at the furnace/air handler ...
central air conditioning6/24/2009
  Q: I need to replace my central air conditioner and gas furnace, I am leaning toward the duel fuel ...
  A: I have seen a great many heat pump systems in the 15- 25 yr old range. Is the normal life span of a ...
hvac6/23/2009
  Q: We installed a new frigidaire hvac unit in 2004. We have had nothing but trouble w/ the temperature ...
  A: Not enough cooling, freezing up and water leaking sounds like the symptoms of a refrigerant leak. It ...
Hard Start Kit for Residential A/C6/22/2009
  Q: I have a small ductless mini split system (Heat Controller, Inc.) that conditions a room over a ...
  A: If the run capacitor was ok but the compressor wouldn't start then the hard start kit kept you from ...
A/C not cooling well.6/21/2009
  Q: I have a two story home with separate units for each floor. I never have the downstairs(basement) ...
  A: It could be a number of reasons. 68 degrees is a bit below the normal comfort range of 72-76 ...
Line insulation6/21/2009
  Q: I noticed that only the large line (1/2"-3/4") from the heat pump to the air handler is insulated ...
  A: The smaller of the 2 lines is the liquid line and the liquid refrigerant in the line has been cooled ...
Melted AC Drain Pan6/21/2009
  Q: I have a goodman GMPN100-4. Turned on the AC for the first time and had water all over the floor in ...
  A: There is a good chance that the drain pan was damaged when the blower motor failed if the furnace ...
Honeywell Chromotherm 3 not working?6/20/2009
  Q: I have a Honeywell Chronotherm 3. When I turned the AC on the first time this year, the fan would ...
  A: It could be either. Check the battery contacts on the thermostat to make sure that they are not ...
Attic fan versus whole house fan6/20/2009
  Q: My husband and I moved into a 3 year old two story home. The AC works great on the first floor but ...
  A: A temperature actuated attic exhaust fan will reduce the temperature difference between the attic ...
reaching absolute optimal freon charge6/20/2009
  Q: For years (I'm 55) I have wanted to know how to reach supercool or optimize using supercool method ...
  A: I have to assume that your system has a fixed metering device rather than a txv. The most accurate ...
seer6/20/2009
  Q: Can a 12 seer inside coil be matched with a 13 seer condensing unit? We installed a new furnace and ...
  A: Yes a 12 SEER indoor coil will work with a 13 SEER condensing unit. You will not achieve a 13 SEER ...
AC drain line blowing cold air6/20/2009
  Q: There is a pvc line exiting the AC unit that has a short piece of pvc sticking up that is blowing ...
  A: The pvc line is the condensate drain line for the A/C. If the evaporator coil is on the supply side ...
Central air & water6/19/2009
  Q: I have a Trane XE1000 and the attic unit is dripping water onto the ceiling. It appears that there ...
  A: The most likely cause is a plugged condensate drain line. If the insulation inside the unit is wet ...
Frozen central AC6/19/2009
  Q: My Central AC unit is frozen. We just had it serviced 2 weeks ago, the freon was fine and we also ...
  A: A frozen unit is usually due to inadequate air flow(dirty filter,evap.coil, blower wheel or closed ...
heat pump thermostat doesn't work6/19/2009
  Q: I live in Gulfport, MS. In Feb, contractor replaced old GE heat pump with new XL16 Trane heat ...
  A: If the system runs continuously but doesn't cool down the house it would seem that the problem is ...
lennox ac unit model#10acb24-9p6/18/2009
  Q: my ac wont turn on i have a honeywell electronic thermostat and when i switch to ac the ac symbol ...
  A: The blinking AC normally means that the thermostat is not getting 24volts to power it. If this ...
AC unit6/17/2009
  Q: I have a question about the coil on an American Standard Heat/Air home system. I am not sure how ...
  A: No problem with the length of the question. The more information you give me the better I can ...
R-410 A/C system6/16/2009
  Q: I want to know what should be done on a residental air conditioning unit using R-22 to change the ...
  A: You will have to change both the outdoor unit and the indoor unit. It is also preferable to replace ...
York Central Air Unit6/15/2009
  Q: I have a York Central Air Unit, 3 zones and 2 programmable thermostats. When you first turn the ...
  A: Without being able to see the system setup and directly troubleshoot the system while the problem is ...
Central Air6/15/2009
  Q: I bought a house with a pretty old A/C unit that hasn't worked yet. Today I opened it up and hit the ...
  A: Is the burning smell inside or outside? It could be a motor, transformer, contactor or wiring etc.. ...
Luxaire home central air problem.6/15/2009
  Q: i just moved into a house in Michigan with a Luxaire central air conditioning system that looks ...
  A: It sounds like you may have a system that is well past its prime with multiple problems. If there is ...
Condensor fan replacement6/14/2009
  Q: The fan on my daughters outside condensing unit is making a lot of noise and needs replacing. I am ...
  A: As long as the fan motor is the same horsepower, voltage, rpm, direction of rotation and mount you ...
Trane compressor not turning back on6/13/2009
  Q: I have three trane 4 ton units in my house. When i have a jerk of power meaning it goes off then on ...
  A: If you don't already have one a start relay and capacitor might help. You could also wire a small ...
Goodman central A/C won't run6/11/2009
  Q: Mr. Trimborn, My Goodman A/C services my 400sf condo which is just 2yrs old. I used it 2 weeks ago, ...
  A: If you have a float switch in the secondary safety drain pan it should only be off(open) if there is ...
variable speed air handler6/11/2009
  Q: Live in houston, tx and have a goodman vs airhandler w/ emerg. heat paired w/ 3.5 ton condenser. I ...
  A: I am not sure about the dip switch settings that are specific to your goodman unit. They should be ...
Goodman central A/C won't run6/10/2009
  Q: Mr. Trimborn, My Goodman A/C services my 400sf condo which is just 2yrs old. I used it 2 weeks ago, ...
  A: If the A/H is in the attic you may have a safety float switch in the secondary drain pan under the ...
Convert a 10 SEER to a 13 SEER6/10/2009
  Q: We built our house and moved in Nov 2006. We thought we got a 13 SEER AC unit. This weekend the ...
  A: If the evap. coil will accept either a piston or an expansion valve, then it can be converted. Not ...
Problems with my York6/9/2009
  Q: I have a 3 1/2 ton outdoor York unit, about 18 years old. It has worked flawlessly for these 18 ...
  A: It is probably a bearing wear problem with the condenser fan motor and you may have to replace the ...
blower moter6/6/2009
  Q: bought a blower motor for unit 58gp075-ga and the old motor is 4 speed 9.8 amps and no capacitor, ...
  A: I assume the new motor that you got is the same horsepower,voltage, rpm and direction of rotation. ...
air conditioner capacitor6/5/2009
  Q: i am looking to replace the dual capacitor in our central air conditioner at home, it has a ...
  A: There are a few choices in finding out which capacitor you need. The first is to go to the ...
Corroded coils6/5/2009
  Q: An HVAC technician just left after inspecting my upstairs unit, Carrier 38YCC, which is a little ...
  A: I assume you are talking about the outdoor(condenser) coil on a split system heat pump. At just over ...
Lenox AC6/5/2009
  Q: I have a residential Lennox High Efficiency AC unit about 12 years old (I think it is a 2 ton). ...
  A: "Zerol Ice" is an additive that when added along with the oil already in the system help to decrease ...
AC replacement/split system6/3/2009
  Q: I want to replace a Lennox model 10ac48. Does it matter much if I replace the condenser with another ...
  A: I assume you plan to replace the condensing unit only without replacing the evaporator coil. As long ...
Freon vs. Puron6/3/2009
  Q: I am in the process of getting a new air conditioner. Went on the web and learned there are still ...
  A: While there are no inherent problems with R-410A as a refrigerant itself, it has some ...
Air discharge Temp on cool cycle6/2/2009
  Q: My cooling system seems to run constantly. I checked the air intake temp, 76 degrees, and the air ...
  A: Delta T (difference in temperature between return air and supply air) is normally about 18-20 ...
Heat Pump Not Working in Cooling Mode6/2/2009
  Q: We have a dual heating/cooling system in our home. Heat pump services the upper level. (Trane model ...
  A: The system should be repairable. While it is possible that the compressor failed due to a ...
Replacing A/C unit6/2/2009
  Q: I live in a suburb of Kansas City. The house is approx. 11 yrs old with a Lennox Elite A/C unit. I ...
  A: If the leak can be found and repaired you may be able to get some more life out of the system. A lot ...
ac air handler replacement6/1/2009
  Q: About 4 years ago I had my outside condenser only replaced with a miller 1.5 ton unit at my St Pete ...
  A: It is not unusual for a 25 yr. evap. coil to develop leaks at multiple return bends. I am not ...
Residential air conditioner6/1/2009
  Q: What causes thne large line coming out of the condenser to ice over? What needs to be done to fix ...
  A: The flow in the large (suction) line is back towards the condensing unit. Icing up can be caused by ...
New central air makes me sick and has weird odor?5/31/2009
  Q: I live in a 50 year old home that had a new central air conditioning unit installed. We used to use ...
  A: Cannot tell exactly what the problem is without being able to smell the odor. Possibilities would ...
covering exterior vent pipes5/31/2009
  Q: I used to sell HVAC equipment to contractors before becoming a realtor. I referred an experienced ...
  A: I don't know of anything that is made to cover the vent pipes outside the house. Normally the vent ...
heat pump5/29/2009
  Q: I have an american standard heat pump. At 80 degrees F today I am running a suction of about 80 and ...
  A: I would need more information to have an idea of what is going on with the system. What is the ...
Rusted out drain pan5/29/2009
  Q: I have just learned that the drain pan is rusted out in my 20 year old unit. What concerns should I ...
  A: If an exact replacement for the original drain pan is available that would be an option. At 20 yrs. ...
Lennox Heat Pump5/28/2009
  Q: I bought a brand new house in January and I recently needed the AC function of my brand new Lennox ...
  A: You should only need to switch the thermostat to the cool position to have the A/C run and cool. The ...
upducts5/28/2009
  Q: We no longer use swamp cooler thus no use for upducts in ceiling for swamp cooler and I notice alot ...
  A: The only effective way of keeping the heat from the ductwork from entering the conditioned space ...
"Attic" Smell5/11/2009
  Q: I have a smell coming from the duct work that smells somewhat like the smell of my attic, but ...
  A: Depending on the tightness of the house and the integrity of the return ductwork by the furnace it ...
Central Air Conditioner Question5/11/2009
  Q: I live in a home in AZ I bought brand new 3.5 years ago. First time I noticed that my AC (for ground ...
  A: I lived in Scottsdale for 5 years, so I know what the weather is like. While it is entirely possible ...
Home AC Unit5/11/2009
  Q: I know I'm going to sound silly but I have a Carrier home AC unit. I know that there is a part of ...
  A: You will probably need a service technician to get to the source of the problem. If the inside runs ...
Compressor, coil, air handler5/10/2009
  Q: I'm told that one of my compressors and coils will need to be replaced. Is it normal to replace ...
  A: In a cooling only application, the evaporator coil normally comes with the air handler. If you are ...
Trane heat pump5/10/2009
  Q: I have a Trane split system heat pump about 18 years old. It's model# is TWD724B100A1. Is this a ...
  A: Yes that is a 2 ton system. If you are planning on repairing rather than replacing the system you ...
AC/heaters5/9/2009
  Q: We have a very old (30yrs) Carrier AC/heater combo in Phoenix, AZ, and it currently works well. It ...
  A: Some parts may be available as universal replacement parts and some strictly O.E.M. (Original ...
Fuse blowing on furnace5/9/2009
  Q: I have a York High efficiency Tubular Heat exchange series GY8S Furnace, the thermostat wasn't ...
  A: Blowing the low voltage fuse on the circuit board intermittently can be a very difficult problem to ...
Amana PTAC will not operate5/8/2009
  Q: I have an Amana Model PTH153A35AA ptac (heat pump). the unit is 12 years old. For the last year, it ...
  A: From the price you are telling me that a new unit costs, I am assuming that this is a through the ...
Air conditioner5/6/2009
  Q: I believe I may have emailed you earlier but now another problem. I'm the one with the Emerson air ...
  A: If the compressor is running but the outside fan is not the system will develop excessive head ...
Contactor points5/6/2009
  Q: I have a Cariier unit that sits outside the house, when turning the AC, air comes out of the vents ...
  A: Contactor points are not available as a separate part, you must purchase a replacement contactor. ...
which a/c unit to purchase5/6/2009
  Q: We have two Trane 2.5 ton heat pump, split systems, that are 22 y.o. They both need replacing. We ...
  A: Any brand of system or unit that is rated at the same efficiency and has the same features should do ...
heating and air conditioning units5/6/2009
  Q: Building a new home 2000 square feet and want to know what size units (heating and air conditioner) ...
  A: Old "rules of thumb" for sizing a/c units by square footage are different in different parts of the ...
Cleaning coils on York air handler units5/5/2009
  Q: How do I clean between coils that are sandwiched together?
  A: It depends on how dirty and packed the space between the fins are on the coil. Normal yearly ...
supply register on furnace plenum in basement5/5/2009
  Q: I live in Western NY and have a ranch house with unfinished full size basement with forced air NG ...
  A: The window question is outside my area of expertise, but it seems that if cold air is leaking into ...
Condenser Fan isn't working5/4/2009
  Q: . I live in Ohio ... the heat hasn't hit bad yet, but I noticed when we had the air on the other ...
  A: It could be either the motor or the capacitor. A capacitor can be weak without being "bloated" or ...
S.E.E.R. rating&freon loss5/4/2009
  Q: I moved in two years ago,I have had to get freon every 6to8 weeks since.My home warranty says it ...
  A: SEER rating is the BTU output divided by the watt-hours of energy input over a specific period of ...
supply register on furnace plenum in basement5/3/2009
  Q: I live in Western NY and have a ranch house with unfinished full size basement with forced air NG ...
  A: Closing the register on the supply plenum won't affect the combustion air for the furnace in a full ...
Capacitor5/2/2009
  Q: "Outdoor Capacitor is a 35/5. Lowest allowed by MFR - 32/9. Now testing at 32/7." Replace for ...
  A: Capacitors should be within plus or minus 10% of their rating to operate correctly. If they are ...
heat return5/2/2009
  Q: We live in a capecod with an attached garage. We are finishing off a large bonus room over our ...
  A: The ideal placement for returns and supplies for air conditioning are for both to be high. The ...
TRANE XE-80 heating problrm5/2/2009
  Q: ..I live in CA. Problem with Trane XE-80 heating. ( A/C works fine ). When set to heat, flame comes ...
  A: The normal reason for tripping the high limit is insufficient air flow. Most of the time if the unit ...
1980 model HVAC system versus enery efficiency HVAC system now5/1/2009
  Q: energy saving of using new model HVAC compare to old model 1980 HVAC system. What are the benefit ...
  A: In gas furnaces, the efficiency relates to the percentage of the heat produced that actually goes to ...
Intertherm AC drip pan rusts, plugs, overflows4/30/2009
  Q: My mother's modular home in Michigan has an Intertherm central forced-air combination gas furnace ...
  A: Most newer units have changed to plastic condensate pans, but the older ones were steel. With the ...
new HVAC unit4/30/2009
  Q: I have been getting some estimates for a new HVAC unit. Ours is over 25 years old. I've been ...
  A: The Gibson brand is made by Nordyne. I have not been impressed by either Gibson or Coleman. Try ...
access valve4/29/2009
  Q: on a reciprocating compressor that has a port above the sight glass for a access valve fitting, what ...
  A: Yes you can add oil through the suction port. HVAC parts suppliers have pumps specially designed for ...
American standard vs trane and amana4/28/2009
  Q: I am getting a quote from different contractors to install a 3 ton a/c unit.. I have quote of 6000 ...
  A: Trane and American Standard with the same features and efficiencies are basically the same unit. If ...
Conversion to multi-zone possible?4/28/2009
  Q: I have a 30-yo 2500 sq-ft home in Northern Virginia with forced air heat and AC. Single zone ...
  A: I can't really answer the question as to cost because I have never priced out that type of job for a ...
Outside Compressor issue4/27/2009
  Q: I had a heating contractor fix my furnace this winter and I just tried using our A/C but the outside ...
  A: The terminal marked Com24v is the same as C. There are normally 4 wires coming from the thermostat ...
Goodman 13 Seer Heat Pump Problems4/27/2009
  Q: Our power more than doubled 4 months ago so we had the people who installed come out and look at our ...
  A: It sounds as if you have a leak in the system. While it's possible that there was a leak at the cap ...
Rheem RQKA-A042JK With Option 5414/27/2009
  Q: My unit is freezing up. So I contacted a local ac tech. He came out and charged my system for me ...
  A: 55-65 psi on an R22 system corresponds to just below or just above freezing(32 degrees). When run at ...
HVAC unit blower4/27/2009
  Q: You have previously answered this question .The fan on my air conditioner/heater system will not ...
  A: Some questions are specific to individual units/brands and can't be taken as a general across the ...
Running Central AC with cover on4/26/2009
  Q: My super intelligent wife has been running the Central Ac unit of my house for 20 hours with the ...
  A: It is possible that you have a dead compressor. Running the unit with the cover on will cause ...
gas furnace fan rumbles4/26/2009
  Q: I have a coleman presidential 7600b series gas furnace from the 70's in my 70's trailer house. ...
  A: This problem can have a number of causes. The blower wheel can be out of balance or dirty. The ...
breaker / to much voltage4/26/2009
  Q: Good morning,The problem i'm having is with my central air ! when i go to turn the a/c on the ...
  A: 260 to 300 volts seems high for supply voltage. Most electric service providers regulate the supply ...
a/c causing damp wall4/26/2009
  Q: my a/c split unit has a pipe to lead the waste/condensed water out of the house. this pipe(set in ...
  A: Depending on where the unit is located it may be possible to use a condensate pump by the indoor ...
air conditioning4/25/2009
  Q: I have hot water heat in an older house. How can I install air conditioning? Thanks......Darlene
  A: One of the easiest ways to install A/C in a house with hot water heat is to use a high velocity/low ...
Payne Heat Pumps4/25/2009
  Q: I need to replace a 23 year old 2 ton York heat pump on a rental unit. The best bid that I've ...
  A: Builders models of HVAC equipment are generally the lowest cost bare-bones types of units. They tend ...
What heat pump unit with gas pack is best4/25/2009
  Q: my present heat pump is 18 years old. It has been serviced regularly and is still working fine, but ...
  A: I am not familiar with the lowest winter temperatures that you see in that area. Do you have only a ...
no air from ducts4/25/2009
  Q: I have a Goodman heat pump/AC, and the air filter has been changed, and there is power supply to the ...
  A: Some Goodmans use a time delay relay to delay both the starting and stopping of the blower motor. ...
outside york unit4/24/2009
  Q: have 2 york's outside, one runs upstairs, little bigger one runs middle floor and basement, the one ...
  A: If the compressor and fan run when you push in the "points" on the contactor it would indicate a ...
burned up motor in furnace and a/c4/24/2009
  Q: I just found out that my a/c unit burned up a motor. How does that happen? What can a DIY do fix the ...
  A: From what I understand, the blower motor in your furnace burned out while you were running the air ...
outside york unit4/24/2009
  Q: have 2 york's outside, one runs upstairs, little bigger one runs middle floor and basement, the one ...
  A: Since both the fan and the compressor will not run the problem should either be no line voltage ...
drip pan overflow4/23/2009
  Q: where can I purchase a overflow switch that would shut off the ac and possible sound an alarm or ...
  A: A number of types of safety switches are available for drain pans that will install in either the ...
rheem4/22/2009
  Q: have a upflow rheem as a piggyback on heat pump with control board that goes into emergency heat no ...
  A: It is very difficult to diagnose a problem without being on the spot and able to logically follow ...
copeland compressor4/22/2009
  Q: steps on how to add oil to a compressor? what equipment is needed for the job? any tips? thanks.
  A: Why do you need to add oil to a compressor? Most new and replacement compressors are shipped with ...
heating problem4/22/2009
  Q: I have a comfortmaker furnace that comes on, the pilot lights but gas never flows. If i take the ...
  A: If the furnace has an intermittent pilot that always lights off, but you do not always get the ...
time delay relay4/21/2009
  Q: Looking for a time delay relay for a 36000 Btu Friedrick a/c. Have a generator in power system when ...
  A: Time delay relays are usually available through an HVAC supplier(most will not sell to an ...
furnace not working after power outage4/21/2009
  Q: I'm having a problem with my gas forced air furnace after just recovering from a 4 day power outage ...
  A: Check the low voltage at the circuit board first. If you have 24v at the circuit board, the problem ...
furnace not working after power outage4/21/2009
  Q: I'm having a problem with my gas forced air furnace after just recovering from a 4 day power outage ...
  A: Without being there to troubleshoot it is difficult to diagnose. Do you have 24v between R and C on ...
Mitsubishi 3.5hp split system air conditioner4/20/2009
  Q: My Mitsubishi 2 way split system air conditioner about 7 years old has stopped working. I recently ...
  A: Very difficult to diagnose without actually being there to check the unit. How long was the unit ...
replace theromstat4/19/2009
  Q: i live in socal., and i recently replaced an old mercury run 4 wire thermostat with an honeywell ...
  A: Was the old thermostat working when you replaced it or did you replace it to try to solve a problem? ...
Smell Of Death4/18/2009
  Q: There is an extremely foul odor coming from our vents.Even when the heat or a/c is shut off it is ...
  A: I would think that a pest control company would have experience in removing dead or live pests from ...
Gibson GL1RA series4/17/2009
  Q: My tenant reports that one morning the pre-programmed thermostat did not kick on the heat as usual. ...
  A: Very difficult to say without being there to troubleshoot when the problem was happening. The first ...
ac handler4/17/2009
  Q: Ineed help and this is the problem: "Compressor will kick on but the air handler will not" I ...
  A: It could be a number of things. Some Goodmans of that approximate age had time delay relays to turn ...
heat calculator pump4/17/2009
  Q: What does it mean when the light in on and it says to call for heat calculator pump?
  A: You haven't given me very much information to work on. What type, make and model of equipment are ...
Heat Exchange Unit4/16/2009
  Q: I have an older forced air furnace (Carrier DNP 24cc-9). I was told recently that the heat ...
  A: Most heat exchangers can be replaced if they are available, but manufacturers generally only have ...
hvac unit on roof of house4/15/2009
  Q: is it okay to mount an hvac unit on the roof of a house or is it a code violation? the house is ...
  A: I am not sure about local(or association) codes in your area, but when I lived in Scottsdale AZ it ...
Leniox Furnace model VR82004/15/2009
  Q: I have a Leniox furnace model vr8200 and I can not find the filters.. the furnace is in my attic.
  A: All newer furnaces have been mandated to ship with a means of filtering integral to the unit. This ...
troubleshooting HVAC4/14/2009
  Q: What are the symptoms of a dirty evaporator coil. What will my pressures and temperatures read. ...
  A: ??? Ambient temperature is outside temperature. No relation to SEER rating except for the specific ...
Bryant gas furnance works randomly4/14/2009
  Q: I have a Bryant Model 376CAV048095 Gas furnace. It was working randomly by turning on and off the ...
  A: The circuit board powers the gas valve after a predetermined amount of time to warm up the hot ...
Finding A/C System leak4/14/2009
  Q: During a recent checkup My mom's Lennox 10 SEER 2 ton with Armstrong indoor coil has developed a ...
  A: ultrasonic leak detectors are really good at finding leaks in hard to reach places where sniffers or ...
rheem furnace4/14/2009
  Q: I have an older rheem furnace and it has worked perfectly for the past 8 years I have owned the ...
  A: On a standing pilot system where the pilot will only stay lit for a short amount of time the problem ...
adding an economizer to an existing system4/14/2009
  Q: i have a luxaire package ac and heat unit model # dl-05ni3ataaa1 serial # noc6124606 5ton unit. The ...
  A: Is this for a residential system? Most package units have the ability to accept an economizer, but ...
AC unit replacement4/13/2009
  Q: Currently in the process of getting quotes on replacing my 13 year old AC/heating unit. My current ...
  A: It's always helpful to know what area of the country that you live in in order to try to answer most ...
condensate pump4/12/2009
  Q: i recently switched my air handler from gas to electric the problem is installing a condensate pump ...
  A: When switching from gas to electric furnaces supply voltage is normally increased from 120V to 240V. ...
troubleshooting HVAC4/11/2009
  Q: What are the symptoms of a dirty evaporator coil. What will my pressures and temperatures read.
  A: Temperature difference across system in either heating or cooling will increase( difference between ...
Combination Boiler/Furnace Operation4/11/2009
  Q: I recently saw a combination oil boiler / heat pump. How do I determine which is primary heat and ...
  A: I am not familiar with these combinations. Boiler(hot water/steam) and Furnace(forced air) or oil ...
NuTone ComboPak HVAC4/10/2009
  Q: Mr Trimborn, I currently have a Goodman combopak HVAC and have replaced just about every component. ...
  A: Mark, I am not sure what you mean by a combopak? Residential split systems have a furnace inside ...
a.c. will not run4/10/2009
  Q: Kenmore condenser unit, app. 5 yrs. old 2 ton, grandaire air handler same as ruud, brand new 2 ton. ...
  A: I am assuming that this is an A/C ONLY system. Is the new tstat a honeywell T86F? Some new tstats ...