| Subject | Date Asked |
|
| Gas furnace Blower noise | 11/20/2009 |
Q: The blower started to make a whining noise. The blower motor appears to be turning normally. I saw ... A: Rich, It sounds to me like you are describing the draft inducer motor not the blower. What is the ...
|
| heat pump, little heat, | 11/19/2009 |
Q: I'm new to this, and I have a little schooling on this, so here is the problem. I have a heat pump ... A: Gary, Well now.......could be they wired the lock out for the strips backwards and they won't work ...
|
| Wishing the death of 18 yr old heat pump | 11/19/2009 |
Q: I just bought a home with a 18 yr old Carrier 2.5 ton heat pump. The furnace was replaced last year. ... A: Angela, Wow, thank god your poor husband got out from that marriage. And FYI your rating will be ...
|
| Gas central heat unit | 11/19/2009 |
Q: I am replacing the thermocouple that keeps the pilot light lit and I notice that there is a lot of ... A: Bill, The air that is mixed with the gas has impurity in it. Depending on the area and the area ...
|
| Little air flow from duct work | 11/18/2009 |
Q: My husband and I are building our own home. We purchased a outdoor wood hot air furnace WADENA. Our ... A: Amy, Going to need more info to answer your question.An 8" duct cannot move even half that amount ...
|
| heat pump, little heat, | 11/18/2009 |
Q: I'm new to this, and I have a little schooling on this, so here is the problem. I have a heat pump ... A: Gary, The thermostat should have first and second stage heat, second stage is usually wired ...
|
| amana 90 | 11/18/2009 |
Q: I have a amana 90 furnace that will light sometime and sometimes it won't light i think it might be ... A: Aki, I need a bit more info....Is the lighting device a Hot Surface Ignitor, spark with a pilot, ...
|
| Thermostat | 11/18/2009 |
Q: John, I have recently purchased a new house. It's over 1 1/2 years old..no ones has lived in it. We ... A: Bill, Here is the owners manual for that thermostat. ...
|
| heat pump | 11/17/2009 |
Q: I hve a carrier unit modle # fb4anf030. also have a programable thermostat. went to adjust heat ... A: Todd, I am not sure what you are asking. Where do you hear a hum? And you are sure it is a ...
|
| Intertherm heatstrip air handler(mod home) | 11/17/2009 |
Q: My neighbor has a intertherm air handler that is heating, but will not turn the fan on in auto on ... A: John, Ih the cooling mode the blower is turned on by a small black relay that is in the upper left ...
|
| Heat Pump Pressures | 11/15/2009 |
Q: How do you determine if the compressor valves are bad or the reversing valve is not shifting 100% ... A: Bill,\ Sorry I mistook your knowledge level. It will depend on the degree of leakage. In other ...
|
| Wishing the death of 18 yr old heat pump | 11/15/2009 |
Q: I just bought a home with a 18 yr old Carrier 2.5 ton heat pump. The furnace was replaced last year. ... A: Angela, I do not answer private questions that ask to break the law!!!!!!!!!!!!!!!!!! But I will ...
|
| Heat Pump Pressures | 11/15/2009 |
Q: How do you determine if the compressor valves are bad or the reversing valve is not shifting 100% ... A: Bill, Simple answer bill. You check the amp draw of the compressor while it is running. If the ...
|
| american standard freedom 70 propane furnace | 11/14/2009 |
Q: our furnace is 9 years old. It is american standard freedom 70 propane with one zone. Recently, ... A: Sherry, It is not the control board. There are several reasons for that "fault" code, but most ...
|
| freezers | 11/14/2009 |
Q: Can a freezer be transported on it's side and then be set upright and work without problems, or are ... A: Ron, Although it is highly recommended not to do that, if you do then you must have it upright and ...
|
| Vibration from Heat pump | 11/13/2009 |
Q: We have an outside AC unit/heat pump. The unit kicked on all last winter and all summer providing ... A: Micah, The first thing would be to look at the fan blade on the top while it is running and see if ...
|
| PROGRAMMABLE TSTAT | 11/12/2009 |
Q: I recently installed a rite-temp model 6036 7 day programmable tstat to update my heat pump. i ... A: Kurt, That thermostat will work fine on your heat pump, it just has to get wired correctly. So, ...
|
| payne furnace | 11/11/2009 |
Q: igniter lights, furnace fires and stays lit, blower comes on, spark ignition continues to spark when ... A: Barry, You want to be careful not to break the ceramic, but the rod needs to be in a position to ...
|
| Rheem Criterion II Noise | 11/11/2009 |
Q: This furnace is 8 years old & installed in a 2000 sq ft 4 bdrm house in SoCal. It makes a whining ... A: Don, In that case it might be, I got the impression from the way you wrote the question this has ...
|
| Rheem Criterion II Noise | 11/10/2009 |
Q: This furnace is 8 years old & installed in a 2000 sq ft 4 bdrm house in SoCal. It makes a whining ... A: Don, The sound is coming from the louvers on your return air grill. Take some needle nose pliers ...
|
| AC Unit.... what to do??? | 11/10/2009 |
Q: I'm very confused about a problem with my outside AC Unit and would be really grateful to hear your ... A: Juliet, You should replace it now. 2 reasons....if it dies then the compressor will run EXTREMELY ...
|
| payne furnace | 11/10/2009 |
Q: igniter lights, furnace fires and stays lit, blower comes on, spark ignition continues to spark when ... A: Barry, sorry I wasn't even close,I guess I am getting old,.lol, yes that is the one. Built in that ...
|
| payne furnace | 11/10/2009 |
Q: igniter lights, furnace fires and stays lit, blower comes on, spark ignition continues to spark when ... A: Barry, No, you have a three wire pilot part # Lh360 that needs to be replaced. If you look the ...
|
| Squeal blower motor | 11/9/2009 |
Q: my AC air handler (no heat) is horizontally installed in a hot and tight fitting attic -- a UPG 4 ... A: Patrick, You say direct drive , but it sounds like you have a belt drive is that correct? If so ...
|
| Rewiring a Coleman Elec. Furnance | 11/9/2009 |
Q: I have a Coleman Electric Furnace model 3500a, it has the controls on the furnace. I want to ... A: Doyle, you must have some kind of thermostat, besides the manual fan switch if you have heating ...
|
| Electric Furnace with strange cycle | 11/9/2009 |
Q: I have a airforce central heat/air conditioning. The Furnace is a YORK model N4AHD14A06A (located ... A: Thong, It sounds like you probably have a mechanical fan/limit switch that is in need of ...
|
| humidity in house | 11/9/2009 |
Q: I recently purchased a house and am noticing a problem with very humid air in the house. The windows ... A: Nick, No, windows , being a better grade I assume will just make it worse. What form of heat do ...
|
| Compressor matching air handler | 11/8/2009 |
Q: John, You're so helpful I need to ask you another question. I have a 3 Ton Luxaire Compressor and ... A: Hey Scott, What that means is that you have an air handler capable of 1,600 cfm or air across the ...
|
| Central heating | 11/7/2009 |
Q: my central heating system is 3 months old and 2 months ago i have changed the thermostat to a ... A: Niles, When you open the door you stop power to the circuit board and it clears any faults, or ...
|
| air conditioner | 11/6/2009 |
Q: I currently have a 4 ton 14 seer Rheem bought in 1998. Then handler and the condensing unit are ... A: Lisa, Sounds like you have an air flow problem or the unit is not charged correctly. That TXV ...
|
| Air Handler | 11/4/2009 |
Q: I have a UPG Model MA Modular non-variable speed air handler. It is hooked up with ac and forced ... A: Scott, You did not tell me that it was that way for a year!!! The fan runs when there is power to ...
|
| Trane XB1000 Problem | 11/3/2009 |
Q: This pas Saturday my AC kicked on and the Trane XB1000 that sits outside my house start making this ... A: Eric, First go out and spin the fan blade with nothing on, if it does not spin freely and go for a ...
|
| Trane XL 90 not igniting | 11/3/2009 |
Q: My Trane XL 90 is not igniting. The AC/fan works fine. When I turn the heat up on the thermostat, ... A: Joe, If the blower motor is bad ( check by switching tstat fan switch to on) then the furnace ...
|
| Air Handler | 11/3/2009 |
Q: I have a UPG Model MA Modular non-variable speed air handler. It is hooked up with ac and forced ... A: Scott, The fan gets it's power through the G wire and the tstat has a fan ON/Auto position. If ...
|
| Little Giant Pump Company VCMA-20 Series | 11/3/2009 |
Q: I saw you gave some great advice, so I had a question for you. I have a Little Giant Pump Company ... A: Jeff, I have actually had that happen. The micro switch reverses it's operation. You need a new ...
|
| Wall Heater | 11/2/2009 |
Q: I have a wall heater from williams company, its a old heater as the cold weather starts i turn on ... A: Sam, You need to change the thermocouple, the rod the pilot light hits and gets hot. It has a ...
|
| Heat Pump | 10/31/2009 |
Q: I have a Ducane 4 ton heat pump HP12B48 S/N 4468700322, Compressor ZR47K3FPV135 (scroll). The ... A: David, You have either a refrigerant or an air flow restriction. It would not be the indoor txv ...
|
| American Standard vs. Carrier | 10/31/2009 |
Q: I am going to be replacing our twenty year old gas furnace with a new 95%unit, so that we can ... A: Bob, American standard is Trane. And from a tech's point of view, Trane is far superior to the ...
|
| Replacing Air handler | 10/30/2009 |
Q: My air handler is rusty and the system leaked...and was repaired a month ago. The system is 10 ... A: Walt, What "system" was repaired? I can tell you this. For you to loose a compressor in 8 years ...
|
| Day & night 373lav | 10/29/2009 |
Q: I have a day & night 373lav Horizontal that will not open the gas valve. They provide a pretty handy ... A: Don, There are tons of boards out there, Don, but I believe that one gets the gas valve voltage ...
|
| programmable thermostat | 10/29/2009 |
Q: I'm trying to install a Honeywell Programmable thermostat to replace a Comfortmaker. I've got the ... A: David, I have not seen one with a #4. But the R & Rc are 24 hot, the W is heat, The G is for the ...
|
| goodmen ninty-two furnace | 10/28/2009 |
Q: when i turn it on and go down and watch it . blower comes on glows up clicks then trys again it ... A: Mike, The path for the 24 volts to the gas valve goes through the pressure switch and then up into ...
|
| Water damage? | 10/28/2009 |
Q: I just resently had a tolet flood, and when it flooded a lot of water got into the heating vent next ... A: William, It has to be either metal or flex. If it is metal and there is a vent cut into it, you ...
|
| Water damage? | 10/28/2009 |
Q: I just resently had a tolet flood, and when it flooded a lot of water got into the heating vent next ... A: William, Will need a lot more info to even venture a guess. Is the water closet directly above ...
|
| Sticking Fan | 10/27/2009 |
Q: At times the fan on our a/c unit won't spin. When we push the fan even a little bit it starts back ... A: Kathy, The problem is the run capacitor. That is a PSC ( permanent split capacitor ) motor. The ...
|
| Heating System | 10/26/2009 |
Q: My daughter just bought a townhouse and moved in about 3 weeks ago. She has electric forced hot air ... A: Susan, she can turn the temp wherever she wants, I don't know what yahoo told her that. And if the ...
|
| Gas furnace | 10/25/2009 |
Q: Tried to start the gas furnace but it will not light. I have checked all the safety ... A: Roger, Depending on the furnace, you will need to look at the schematic....the safties and ...
|
| Gas furnace | 10/24/2009 |
Q: Tried to start the gas furnace but it will not light. I have checked all the safety ... A: Roger, So, you did not say....does the ignitor lite up? if so and you have checked the gas ...
|
| Low cfm/velocity problem | 10/24/2009 |
Q: Could having too much cold air return(16x32 cast iron floor grate over two floor joist cavities 8x15 ... A: Ryan, Having a bit of a problem with your descriptions. But you cannot have to much return air as ...
|
| temperature set on thermostat not recognized | 10/23/2009 |
Q: The tenant called me and said that after one of the big storms when the power went out, they came ... A: Laura, Thanks for the compliments, but I need more info than that. If it is a heat pump the ...
|
| Calcium build-up on brand new HVAC? | 10/23/2009 |
Q: Our new 3.5 ton HVAC system was installed January, 2009. We used the heater from January through ... A: Joan, OK, first let us address the load calculations. Who did them and by what method? If they ...
|
| Calcium build-up on brand new HVAC? | 10/9/2009 |
Q: Our new 3.5 ton HVAC system was installed January, 2009. We used the heater from January through ... A: Joan, At your furnace location is the indoor coil. Hopefully they used a cased coil, which has a ...
|
| Calcium build-up on brand new HVAC? | 10/8/2009 |
Q: Our new 3.5 ton HVAC system was installed January, 2009. We used the heater from January through ... A: Joan, That seems extreem yes. But, the water that is condensed on the coil that would leave the ...
|
| furnace return air | 10/8/2009 |
Q: I have a high efficiency furnace and it has the PVC inlet and exhaust directly vented to the ... A: John, That is called make up air. Homes are built so tight now that we must introduce fresh air ...
|
| Heil furnace not providing heat/running properly | 10/7/2009 |
Q: I have Heil condensing gas furnace, model NTG9075FGA3 (manufactured by International Comfort ... A: Jason, If you didn't remove all the rocks from the pvc flue the pressure switch will not make. ( ...
|
| superheat/subcool | 10/6/2009 |
Q: I have just entered the a/c trade and I am attending school. We have been going over the ... A: Kaleb, First there is no 30 inches only 29.96 and service gauges are way off. Remember that when ...
|
| superheat/subcool | 10/6/2009 |
Q: I have just entered the a/c trade and I am attending school. We have been going over the ... A: Kaleb, VERY GOOD....one of the only opposites in physics is heat as there is no opposite, just the ...
|
| superheat/subcool | 10/6/2009 |
Q: I have just entered the a/c trade and I am attending school. We have been going over the ... A: Kaleb, Very good question. I love to help students of our field. You are correct in your ...
|
| HE Gas furnace | 10/5/2009 |
Q: We moved into a house that has a high efficiency forced air, natural gas furnace installed. The ... A: James, Good job on the filter. Do yourself a favor and get the cheapest pleated filter made and ...
|
| Heat Pump Not Dehumidifying | 10/5/2009 |
Q: The following is a summary of questions remaining after 2 "best of phoenix" ac companies, with clean ... A: Lisa, sorry got the last one first. Secret??? Demand them you paid for the job. And it sounds ...
|
| Heat Pump Not Dehumidifying | 10/4/2009 |
Q: The following is a summary of questions remaining after 2 "best of phoenix" ac companies, with clean ... A: Lisa, A TXV is simply a valve that slides one way to restrict the flow and the other to open the ...
|
| ice build up on outside unit | 10/4/2009 |
Q: I have a goodman central air anda heat for house in florida. this morning i heard a strange noise on ... A: Pat, Your filter??? It is probably clogged solid, if so change it and turn on the fan. If air ...
|
| Burner cuts out fan stays running | 10/4/2009 |
Q: Ducane gas furnace with Smart Valve and HSI pilot/sensor...draft inducer fan comes on, ignitor will ... A: Tim, It is not supposed to keep the HSI lit. A volt meter needs to be used on the valve to see ...
|
| what size and type | 10/3/2009 |
Q: i bought a home in eastern ky. complete remodel. 2 story. 1577 sq. feet each floor. the front of ... A: Will, I can't help you with the power bill either....lol I am not familiar with ky weather. If ...
|
| my heater is no working | 10/2/2009 |
Q: I have a Philco heating and cooling product model G6RA 072C-12A. The AC is working fine but I can ... A: I am unfamiliar with the type of lighting system that furnace uses, but if it is less than 15 ...
|
| FURNACE NOT STAYING ON | 10/2/2009 |
Q: I HAVE A CARRIER FURNACE THAT WILL NOT STAY ON. I HAVE CHECKED AND CLEAN WITH SAND PAPER THE FLAME ... A: Here is a link to get an owners manual to help with the fix ...
|
| RHEEM 80 Imperial | 10/1/2009 |
Q: I have just purchased a house and the HVAC unit is a RHEEM 80 Imperial. It has worked well all ... A: George, It is possible the pilot is plugged, but the majority of the time, that is the way the ...
|
| Smell from furnace | 10/1/2009 |
Q: I turned my forced air gas furnace on for the first time this year, and there is a strange smell ... A: Erica, Generally the first time you fire off the furnace the heat exchanger is coated with dust and ...
|
| Air conditioning question | 10/1/2009 |
Q: I am a bally's (gym) instructor and also an amateur at home building. Being a san diego resident i ... A: Leah, You have a couple problems. First you have a mis matched system it should be a 2 ton coil. ...
|
| Residential Heat Pump | 9/30/2009 |
Q: We are older folks renovating an even older two story home in Maryland. The house in about 2500 ft2. ... A: Leo, Before you make that decision on the radiant heat you should check out these boilers, they ...
|
| Thermostat and auto changeover | 9/30/2009 |
Q: Have a functioning system in either heat or cool mode, but in auto mode it will only respond to the ... A: Steve, First of all if it is the thermostat don't get a hunter, get a honeywell, only a few ...
|
| Thermostat and auto changeover | 9/29/2009 |
Q: Have a functioning system in either heat or cool mode, but in auto mode it will only respond to the ... A: Steve, I would call the owner of that company and insist on them making it right with you. Have ...
|
| Rudd Air Conditioner about 6-8 yrs old | 9/29/2009 |
Q: My air conditioner will not turn on, if I push down on the contact points it runs, as soon as I let ... A: Geoff, It sounds like best case you blew a 3 or 5 amp fuse on the circuit board inside the blower ...
|
| new furnace | 9/29/2009 |
Q: I live in N/W Indiana and have a 32 year old 100,000 BTU natl. gas furnace made by Rheem that still ... A: Jurgen, If you look your old furnace was 100,000 btu input and probably 70, 000 or so " bonnet " ...
|
| AC compressor | 9/29/2009 |
Q: My outside unit is 17 years old and the compressor has shorted out. I have a home warranty and it ... A: Charles, It depends on your warranty coverage. I would be amazed if it covers all costs of a ...
|
| Heat Pump in Midwest | 9/29/2009 |
Q: I've heard a lot of negative things on heat pumps in the mid west. I live in Topeka, KS and am fully ... A: Travis, Whoever is bidding the equipment should supply you with a worksheet that comes up with a ...
|
| outdoor central a/c unit | 9/28/2009 |
Q: Hello there. Okay...I am renting a mobile home in Alabama. My landlady lives in Virginia, and ... A: Shannon, That radiator thing is called the evaporator coil and if you look at it when the pipe in ...
|
| Trouble with new A/C | 9/28/2009 |
Q: I got a new airconditioner about a month ago. Since then, it doesn't work the way my previous (22 ... A: Tim, If when you lost power, you went into a brown out, or low power before it dropped out it is ...
|
| AC motor | 9/28/2009 |
Q: We installed a new 5-ton A/C unit about six years ago. Over the weekend the capacitor blew and it ... A: David, A potential problem in the future?? What the heck does that mean? and that motor only ...
|
| aircon compressor loading | 9/28/2009 |
Q: Mike , i am involved in a green building information , education and supply operation on the island ... A: You are asking questions that would take a great deal of my engineering skills, much more than I am ...
|
| Rudd Air Conditioner about 6-8 yrs old | 9/27/2009 |
Q: My air conditioner will not turn on, if I push down on the contact points it runs, as soon as I let ... A: Geoff, I will assume that the wire was outside, that is usually where puppys like to chew them. ...
|
| ac unit in condo | 9/26/2009 |
Q: I have an intermittent cooling problem - Compressor is on roof and installed in 2001, along with ... A: Lylah, Tell your friend that it is a possibility that the condenser motor is going bad and that it ...
|
| coil matching with heat pumps | 9/26/2009 |
Q: I have a thermo pride 106,000 btu oil furnace (1 year old). I have the local hvac people installing ... A: Dragan, you need to tell me if the coil matches the outdoor unit tonnage. If it is a 4 ton then ...
|
| ac advice | 9/25/2009 |
Q: I bought a home with a 4 ton evaporater coil A-SLB484422T+D all style ,this is asplit unit and the ... A: Carol, You only have a 2 1/2 ton compressor with a 4 ton evap coil? Yes you have a problem. Low ...
|
| Rheem Corsair Air Conditioner | 9/24/2009 |
Q: I have the above ac unit model# FADC-0305AS. It has stopped cooling at its normal capacity and I ... A: Eric, Make sure you have a clean filter and all vents are open. Then after 10 minutes running on ...
|
| Carrier 58MVP -100-F-1-20 | 9/24/2009 |
Q: install 03.worked thru spring 09.bsmt location.vents thru roof of 2 flr house. lgth and bends ok to ... A: Terry, Are any of these techs(?) writing down and reporting to you any physical data and ...
|
| Heat pump Blower Motor | 9/24/2009 |
Q: I have a 1750 sq ft ranch home. 3 ton Carrier heat pump. Blower motor died. Local guy charged $979 ... A: Dan, The price you were charged was for a variable speed motor with a motor controller attached to ...
|
| Crawlspace Conditioning | 9/23/2009 |
Q: I live in southwest Ohio, gratefully enjoy all 4 seasons of the year. I recently bought my first ... A: Kathy, Probably the simple solution for your problem is when the central hvac system is up and ...
|
| 4 ton Trane xl16i isn't doing the job. | 9/22/2009 |
Q: I’ve been thinking a lot about the AC pad and how the condensers are arranged. I measured the area ... A: If those numbers are accurate, you have 7 degree's of sub cooling and 37 degree's of superheat, ...
|
| blower | 9/22/2009 |
Q: i have a ruud fuel furnace. not sure what model. it appears to have 2 thermodisc. as it's warming ... A: Dan, Without a little more info it is hard to answer this one. As you look at the furnace, behind ...
|
| ac unit in condo | 9/21/2009 |
Q: I have an intermittent cooling problem - Compressor is on roof and installed in 2001, along with ... A: Lylah, John Borgman here, got this out of our question pool. It sounds to me like the compressor ...
|
| T-stat mystery | 9/20/2009 |
Q: I have a central a/c system and the temp stays pretty much even with a 1 or 2 degree differential ... A: Marshall, John borgman here got this out of our question pool. So when you have it set at 78, ...
|
| Residential A/C question | 9/17/2009 |
Q: I have two identical residential 2ton split A/C units. They are 16 years old, Goodman, and use ... A: Tom, I would have the N.A.T.E certified tech check the other unit since he also added to it, it ...
|
| increasing aircon efficiency | 9/17/2009 |
Q: Mike , i am involved in a green building information , education and supply operation on the island ... A: Stephen, You are correct about the conduction of water over air, it is 8 times as efficient. As ...
|
| Residential A/C question | 9/17/2009 |
Q: I have two identical residential 2ton split A/C units. They are 16 years old, Goodman, and use ... A: Tom, I don't know where to start with you, except, holy cow!!!!! You are so over charged you are ...
|
| Blower works for 30 minutes then locks | 9/15/2009 |
Q: I have a Lennox dual climate AC unit and had issued today with the temperature being warm in the ... A: David, You either have a bad condenser fan motor or more likely a bad run capacitor. When the ...
|
| Freon leak | 9/15/2009 |
Q: My upstairs HVAC system has a slow leak. It is seven years old and the evap. coil was replaced in ... A: Rene', The freon can leak from anywhere it runs through, but on a unit as new as yours, the first ...
|
| Fixed vs variable speed ac | 9/14/2009 |
Q: I've been given varying opinions concerning fixed vs variable speed ac units. Seems it's a 50/50 ... A: Mike, Sounds like you are doing your homework, although, I have no clue as to the lightening ...
|
| Trane XL 1200 super efficiency weathertron heat pump | 9/14/2009 |
Q: About a week ago our outside heat and air unit stopped cooling,and the fan of the unit wouldn't ... A: David, Here is a link as an example. Google trane parts for your area and you can find a dealer ...
|
| a/c leak | 9/13/2009 |
Q: I took out the filter to clean it. I had turned off the A/C and had it turned off for several hours ... A: Gaby, I assume you removed the filter due to it not working, is that correct? And the filter was ...
|
| Lennox AC unit | 9/11/2009 |
Q: I had a technician come out to my home today. We bought our home new about 2.5 years ago. Our ... A: JC, I would not trust this man to work on your equipment. First, his statements about the filter ...
|
| hvac...freon leak | 9/11/2009 |
Q: john, I have an older central a-c unit. it works great, but it has a freon leak. The tech who ... A: Mike, If the leak is that big, the only way to do this is as follows. Fill the now almost empty ...
|
| More on residential AC Dye Test/Leak | 9/9/2009 |
Q: I had a local HVAC company come to find out why my Amana 2.5T central AC system was not blowing ... A: David, Not a clue as which light because it is the wrong thing to do to a system, so I haven't ...
|
| Low Cost Options to fix compressor | 9/9/2009 |
Q: I have a 2.5 ton Comfortmaker outside system with a frozen compressor. I asked about if I could ... A: Clark, You have till January to replace the whole unit with another R22. After that compressors, ...
|
| Brand New Condenser Burned Out | 9/9/2009 |
Q: I really need some help. I bought a new condenser for my house two months ago and it quit running ... A: Cheri, Wow. I don't know what to say tactfully. There is no way that a 3.5 ton condensor should ...
|
| Selecting Thermostat for Heat Pump | 9/8/2009 |
Q: I am seeking to replace my existing thermostat which isn't digital. I have a Carrier Heat Pump ... A: Mitch, I recommend a t8000 honeywell. It has an adaptive intelligent recovery that controls your ...
|
| Gas Ducted heater lockout | 9/8/2009 |
Q: My Dad has a "Stadt" brand gas ducted heater. Last night it stopped working so I had a look. The LED ... A: Greg, Howdy from the USA. Although we do not have that brand here, they all have the same ...
|
| 4 ton Trane xl16i isn't doing the job. | 9/8/2009 |
Q: I’ve been thinking a lot about the AC pad and how the condensers are arranged. I measured the area ... A: I didn't say 20 percent should be recycled, I said that the air discharged is at least 20 degrees ...
|
| Quote for the new HVAC system | 9/8/2009 |
Q: Good morning John, I am in process of purchasing a new home in Houston, TX and I am in need of the ... A: Ismar, You are correct about the R410a and if you plan on being in your home for 15 years, you ...
|
| 4 ton Trane xl16i isn't doing the job. | 9/8/2009 |
Q: I’ve been thinking a lot about the AC pad and how the condensers are arranged. I measured the area ... A: A.J., 9 or 10 will also work for the 2 ton. Moving them will help, although the 4 ton is still ...
|
| choosing a gas furnace | 9/8/2009 |
Q: Any general advice on choosing among Carrier, Lennox, or (much cheaper) Goodman for a ... A: Ted, No Goodman. carrier and lennox are good equipment, personally I put a Trane in my mothers ...
|
| TRANE XL 1200 Humming Noise | 9/7/2009 |
Q: I have an outdoor unit TRANE XL1200 Super Efficiency Air system. All appears to be operating ... A: Ben, You should check the model of that unit, because there is nothing in a straight condenser ...
|
| Thermostat wiring | 9/7/2009 |
Q: I am replacing a contour comfort control thermostat with an Ace hardware brand programmable one and ... A: Mark, Rh,Rc jumpered=red G=green W=white Y=yellow O=orange....this is your reversing ...
|
| air duct cleaning | 9/7/2009 |
Q: I am planning to have my air ducts cleaned and would like to know how to find a company which will ... A: Edward, Your return air should be metal, that is not code and can hold mold in the cardboard. ...
|
| Zone Controller, Low Air flow, and Discharge Temp Sensor | 9/7/2009 |
Q: I just replaced a 10 year old 5 ton York heat pump and air handler and 2 simple thermostats with the ... A: Walt, I cannot help you. I work full time and volunteer 20 to 30 hours a week on here and do not ...
|
| TRANE XL 1200 Humming Noise | 9/7/2009 |
Q: I have an outdoor unit TRANE XL1200 Super Efficiency Air system. All appears to be operating ... A: Ben, I am going to assume you have the heat pump model as you did not say. As such, it sounds ...
|
| Limit Switch | 9/6/2009 |
Q: I had tried to repair the old one which made the condition much better but it still happened a few ... A: Faith, Insist on finding techs that are N.A.T.E certified and this time, if it is not resolved, ...
|
| Zone Controller, Low Air flow, and Discharge Temp Sensor | 9/6/2009 |
Q: I just replaced a 10 year old 5 ton York heat pump and air handler and 2 simple thermostats with the ... A: Walt, Before we address your questions......Bad move with downsizing a 5 ton condenser, with a 3 ...
|
| Limit Switch | 9/6/2009 |
Q: I had tried to repair the old one which made the condition much better but it still happened a few ... A: Faith, First lets address the first guy that worked on it. There is no such thing as a pain in ...
|
| Trane XE1000 | 9/6/2009 |
Q: My unit is 12 yrs old and told the coil needs to be replaced - have had a freon leak for many years. ... A: Christine, Did they show you the leaks? How did they find them? If they only used an electronic ...
|
| Limit Switch | 9/6/2009 |
Q: I had tried to repair the old one which made the condition much better but it still happened a few ... A: Faith, I remember you, yes. So, this is happening when the heat is not being used? Did the old ...
|
| AC?heat pump operation | 9/5/2009 |
Q: When I turn my unit onto heat mode all works fine and heat comes out. Then in a little while the ... A: Rich, Your thermostat has 2 stages of heat, the first for heat pump, the second for aux. heat. ...
|
| A/c fan inside will not come on | 9/5/2009 |
Q: The blower in my squirrel cage quit working properly the other day. I purchased a new switching ... A: Mike, I don't know what you are describing as a switching relay? Is this an electric or gas ...
|
| Trane XE1000 | 9/5/2009 |
Q: My unit is 12 yrs old and told the coil needs to be replaced - have had a freon leak for many years. ... A: Christine, I assume you are talking about the indoor coil? You should still have 10 to 15 years ...
|
| ac/furnace blower motor | 9/4/2009 |
Q: ..I have an old luxaire pcsu-ld08n065b serial number ecwmo84759. The blower motor when the ac is ... A: Jason, Almost all blower motors are 1075 rpm. On the side of the motor there is a name plate that ...
|
| 4 ton Trane xl16i isn't doing the job. | 9/4/2009 |
Q: Question; what are some simply thing I can check to insure my systems are providing peak operating ... A: AJ, The first thing we want to look at is if they are set up correctly as far as the charge and ...
|
| Outside coil went out | 9/4/2009 |
Q: I have a split system HVAC. My outside coil just went out and I tried the breaker but that didn't ... A: No if the disconnect is a breaker and it and the one in the panel are in the on, not tripped ...
|
| Outside coil went out | 9/4/2009 |
Q: I have a split system HVAC. My outside coil just went out and I tried the breaker but that didn't ... A: Hey Alex, The outdoor A/C unit is called your condenser. If the indoor blower comes as it should ...
|
| which product | 9/3/2009 |
Q: We need a new HVAC system put in. Which brand is the best. Trane or Carrier? ANSWER: Jan, I ... A: Jan, Ask him how he knows that, as this new refrigerant has only been in place for a few years. ...
|
| which product | 9/2/2009 |
Q: We need a new HVAC system put in. Which brand is the best. Trane or Carrier? A: Jan, I prefer Trane it is what I put in my mothers house due to the dependability. Cost a little ...
|
| ac/heat thermostat setting | 9/2/2009 |
Q: how should a thermostat be set when a two story house has 2 ac/heating units if we want temp to be ... A: The first thing you need to do is change your air filters. If they get too clogged your equipment ...
|
| Air handler-air conditioner | 9/1/2009 |
Q: I have a five year old rheem blower and a 30 year old compressor that is busted. I assume I would ... A: Al, Your indoor unit is fine, you should get 25 years out of it anyway. The question to ask ...
|
| cracked pan | 9/1/2009 |
Q: my uncle is an hvac guy - don't know his exact title but he told me I have a cracked pan and we ... A: Kelly, Wow, what a nice comment. I hope it works out for you, if not give me a hollar
|
| my centrail air conditioner does not turn on | 9/1/2009 |
Q: I have a comfortmaker snyder general central air. the thermostant works but no cool air coming from ... A: Joe, Kinda curious how you decided that the thermostat works. First of all, lets assume it ...
|
| Rheem RGDG Won't Start or Run | 9/1/2009 |
Q: I have a Rheem RGDG Criterion. I tired to check it out this evening, and noticed corrosion on the ... A: Scott, I don't remember where on that model furnace it is, but there is a ledger that tells what ...
|
| Goodman Gas Pack | 9/1/2009 |
Q: I have a new Goodman Gas Pack - 14.50 seer. When the compressor kicks on, I hear a vibrating noise ... A: Liz, Ok, so you replaced an old unit or is this a brand new install, duct work and everything? If ...
|
| Old Attic Fan | 8/31/2009 |
Q: My house was built in 1941 in Springfield, MO. It is a two-story house and on the 2nd floor in the ... A: Linda, You don't see many " whole house " fans anymore, I have only seen one in the last 27 years, ...
|
| Coil Leak--Lennox Elite 12 CB30M | 8/31/2009 |
Q: I had my a/c company come to the house this morning to do their semi-annual a/c maintenance visit. ... A: Robert, An evaporator coil does not leak under normal wear and tear in 8 years and if it does need ...
|
| Vent location | 8/31/2009 |
Q: We're about to have some work done in our house and have a chance to relocate our AC exhaust vents ... A: Mike, Yes the "supply" vents should be about 6 inches from the exterior walls and over the largest ...
|
| inside coil | 8/30/2009 |
Q: I am buying a 6 year old used 4 ton condenser unit made by bryant and I have forced air I will need ... A: Michelle, It depends on what refrigerant it is, what seer rating, if you are going to use a cased ...
|
| single stage vs double stage and... | 8/30/2009 |
Q: -- 30+ yr old house, thermostat on first floor, occupants like a well cooled and dehumidified second ... A: Tom, There is only one true way to size your equipment. That is with a manual J heat gain/loss ...
|
| Goodman Gas Pack | 8/30/2009 |
Q: I have a new Goodman Gas Pack - 14.50 seer. When the compressor kicks on, I hear a vibrating noise ... A: Liz, How was it checked before it was installed??? If it is brand new the compressor can just be ...
|
| Gas Furnace Recommendation | 8/30/2009 |
Q: I have been getting estimates lately to replace a 30 yr old forced air gas furnace in my home and am ... A: Dave, wow lots of questions...smile Unfortunately your contractors haven't done a very complete ...
|
| winterizing the gas furnace | 8/30/2009 |
Q: John I have a high efficiency lennox elite series gas system,I am needing to know from a technicians ... A: Steve, First of all nice furnace. With the new inshot burners, heat exchangers do not clog as ...
|
| York AC Unit | 8/30/2009 |
Q: What is your opinion of the York. My AC contractor wants to replace my 20 year old Lenox unit with ... A: Marilynn, To be honest York is not one I would recommend. Hardly any one works on them of carries ...
|
| ac not cooling | 8/30/2009 |
Q: My ac unit is about 3 months old, but it works very good at night and early morning, and around noon ... A: Yanet, I will assume you are talking about a central air system. Get on the phone and have the ...
|
| air conditioning and t-stat | 8/30/2009 |
Q: I have a couple questions and I am really hoping you can help solve our dilemma. We purchased a 7 ... A: Beth, It sounds like you could have a few problems. First with the furnace kicking on and off, ...
|
| Fan motor on the outside unit will not run | 8/29/2009 |
Q: I have a RUUD, Model# UAMB-030JAZ. I looked at the capacitor but it doesn't seem swollen or ... A: Marvin, Since that model has a duel run cap, it is most likely the motor itself or the compressor ...
|
| TXV | 8/29/2009 |
Q: We called to have it looked at. The first service tech said the coils are plugged with cottonwood ... A: Thomas, Yes, you can fax him the info, although you might delete the word clown, even if it is ...
|
| TXV | 8/29/2009 |
Q: We called to have it looked at. The first service tech said the coils are plugged with cottonwood ... A: Thomas, I would call the owner of that company and complain. Obviously they do not know what they ...
|
| heat pump | 8/29/2009 |
Q: I have a package heat pump that one day it can not switch to cool it was working fine then only can ... A: Phillip, Still having trouble with the limited info, sorry. If I am following what you are ...
|
| heat pump | 8/29/2009 |
Q: I have a package heat pump that one day it can not switch to cool it was working fine then only can ... A: Phillip, Respectfully your question does not make sense. The reversing valve has nothing to do ...
|
| cracked pan | 8/29/2009 |
Q: my uncle is an hvac guy - don't know his exact title but he told me I have a cracked pan and we ... A: Kelly, Bryant is a carrier product and since you didn't say I assume that you are talking about ...
|
| Rheem rrka-a036 | 8/29/2009 |
Q: I have a 10 yr old Rheem RRKA-A036jk06X A/C+heat unit on my roof. My problem is that I do not get ... A: Steven, Since you are handy with a volt meter this will make this easier. The high voltage first ...
|
| CFM requirements | 8/29/2009 |
Q: 2500 sq ft single story, 4 ton A/C required per manual J calc. Currently two 10" round returns, 1 ... A: Bob, this is a great web site for tinkering around with lots of questions in the hvac arena. As you ...
|
| A/C Blower | 8/28/2009 |
Q: My A/C blower motor has been coming on intermittently. The condensor is not on, nor is there a need ... A: Faith, If you have an older furnace, it might have a fan limit switch that is going out or if you ...
|
| Gas water heater with air return directly behind in unfinsihed upstairs bonus room | 8/28/2009 |
Q: We recently purchased a David Weekly home, finished in '03. Stair from the 1st to 2nd floor lead to ... A: Karla, I don not know the codes there but it cannot be legal to have a return air intake next to a ...
|
| air conditioning | 8/28/2009 |
Q: made a room and conected a 6" duct for the main register in the attic got cold air flowing but can't ... A: Manuel, It sounds like you need more cooling yes. But just increasing the duct size might not do ...
|
| single stage vs double stage and... | 8/27/2009 |
Q: -- 30+ yr old house, thermostat on first floor, occupants like a well cooled and dehumidified second ... A: Tom, In cooling whatever you choose will be on high speed and de humidifiing is part of the ...
|
| Excessive condensation from A Coil | 8/27/2009 |
Q: I have a split upflow central air unit in one of my rentals that yesterday flooded the utility room. ... A: Bill, First if you do not rinse that coil completely you will rot it out. Second another reason ...
|
| R410a presures | 8/27/2009 |
Q: I never had air conditioning in my house, so I just had it installed. It's a Trane condenser 3 ton ... A: Paul, You cannot go by just pressures on any system. The new R410a units, due to the different ...
|
| Outdoor unit wires | 8/27/2009 |
Q: We were weed eating around the outdoor unit and some wires came loose...we don't want to touch ... A: Renae, Going to need more info. First is it just A/C or a heat pump or package unit. Then it ...
|
| Heating a basement | 8/27/2009 |
Q: I have a 6 year old 2,400 sq ft ranch with a basement with 1,400 sq ft finished. I have ceiling ... A: Dan, First closing vents is not the answer, unless your duct system was over sized ( which I doubt ...
|
| ? no super heat? | 8/27/2009 |
Q: i installed a 2ton heatpump system by bryant about a year ago. and always got 1-3 superheat. about ... A: Nick, First of all, you charge a R410a system by sub cooling, the characteristics are different ...
|
| Residential AC Drainage | 8/27/2009 |
Q: I live in a 2-story home built in 1995 with a Lenox AC system. There is some water in the drain pan ... A: Lional, That is a second line of defense and it is only used if there is a problem. Either the ...
|
| Luxaire or American Standard HVAC | 8/27/2009 |
Q: We are looking to replace our 17 year old HVAC system and have quotes from 2-contractors. One ... A: Joe, The American Standard, hands down. First because of the obvious more efficient A/C which is ...
|
| central air clanging sound | 8/26/2009 |
Q: When my central air turns off (as in when the temperature reaches the thermostat) it makes a sound ... A: Nichole, For one thing, if your evap coil was that clogged, now you have a lot more air flow and ...
|
| Outside Central air unit ? | 8/26/2009 |
Q: I have a 10 yrs old Comfortmaker Unit (FBAO36GC) that recently started to make a very loud noise. ... A: Yes, do not use it. There is only one way for this to happen on purpose and that is if you are air ...
|
| payne airconditioner | 8/25/2009 |
Q: i have a Payne aircondition unit and a totaline thermostat last night the low battery signal came on ... A: Steve, Is it calling for A/C? If so, check the breaker for the outdoor unit. If that's not it, ...
|
| Outside Central air unit ? | 8/25/2009 |
Q: I have a 10 yrs old Comfortmaker Unit (FBAO36GC) that recently started to make a very loud noise. ... A: Steve, I don't know if you are talking about the fan for the outdoor unit or the fan for the ...
|
| need for 2 circuit board replacements in one month and frozen A coil | 8/25/2009 |
Q: I have a 2 yr old Amana high efficiency furnace and a/c 3 ton. In June the a/c quit and A/C ... A: Jo, There are two reasons for the A coil to freeze. One is low air flow. ie. dirty filters, vents ...
|
| New A/C not as cool | 8/25/2009 |
Q: I just replaced a 20 year old Trane A/C with a new XR-15 Trane. The installers also replaced the ... A: Roger, More than likely, they did not evacuate the system properly or charge it correctly. Get ...
|
| leak repair | 8/24/2009 |
Q: I have a 3.5 ton outside carrier unit and a slightly larger Lenex unit inside. Had a slow leak of ... A: Sam, I wish you had contacted me first. The way a refrigeration system works and lasts is that we ...
|
| furnace blower whistle | 8/24/2009 |
Q: My gas furnace blower produces a loud whistle when it runs. Usually the whistle fades as the blower ... A: Ken, You are describing the draft inducer motor. It could be bearings or the small blower type ...
|
| AC is barely blowing slightly cooled air | 8/23/2009 |
Q: We have an Armstrong Ultra SX80 ac/heat system. In the last 3 days, we've had a dramatic 75% air ... A: Debra, Loss of air flow and other problems are from the indoor coil freezing up. It freezes for ...
|
| window AC | 8/23/2009 |
Q: I have been looking for a 220 Volt 8000 BTU Window AC because using a 110 volt overloads the ... A: Ed, I dont know the available window units, you might check at home depot as a start. The ...
|
| blower cuts out | 8/23/2009 |
Q: I have a York Diamond 80 res gas furnace. When I set the thermostat to ON the blower will start but ... A: Jamie, You are going to cause more damage than you already have if you do not get a tech out to ...
|
| Replacing Drain Pan | 8/23/2009 |
Q: We have a small amount of water leaking at the base of our indoor unit(Philco B3BM-036K) in the area ... A: John, Generally the pan does not have to be removed to put a new pan in, unless there is no room ...
|
| Goodman pgb042100-1 | 8/22/2009 |
Q: Late yesterday afternoon our ac quit working the condensor fan is not turning and the unit is giving ... A: Sandra, That is one that you need a .tech to come do some checking. It could be a board or motor ...
|
| Rheem/condensor fan stops compressor still running | 8/22/2009 |
Q: Here is my problem(s)I have a 1 1/2 ton Rheem (split system )installed in 99 my fan was stopping and ... A: Robert, There was probably nothing wrong with the other motor. Sounds to me like a bad run ...
|
| 410A Pressure Temprature Chart | 8/22/2009 |
Q: I have a technical question about 410A and pressure temperature charts and i really need some help. ... A: Yes that is correct, but the 10 to 20 is minimum and maximum of units that are made today. ...
|
| 410A Pressure Temprature Chart | 8/22/2009 |
Q: I have a technical question about 410A and pressure temperature charts and i really need some help. ... A: Dharmen, That is not the correct method for charging and temperature refrigerant, even under ideal ...
|
| central air unit | 8/22/2009 |
Q: Ok...during the day today me and the wife noticed it getting hot. I thought the air was turned up so ... A: Ronald, If all you vibrated by hitting the indoor blower motor was the motor, then it either has a ...
|
| Portable Air Conditions for spot cooling | 8/18/2009 |
Q: I recently purchased a used Sunbeam KY 25Y Portable Air conditioner rated at 9000 BTU. It is three ... A: Sharon, How? The leveling part......You will need a small level and then lay it on all sides of ...
|
| _price@yahoo.com | 8/18/2009 |
Q: John I have a carrier central air unit , i push in the contactor the fan and compressor kick on ... A: Chris, You work in the field? I love helping other service or installers. Two things....One ...
|
| No air flow when a/c comes on | 8/18/2009 |
Q: my central air outdoor unit comes on like it should when the thermostat clicks it on but I'm not ... A: Chris, Do you have a volt/ohm meter and know how to use it? If not you are going to have to call ...
|
| New installation of electric furnace and heat pump | 8/17/2009 |
Q: Asked too many questions. So just one more. You said in your last answer "But, with this new info, I ... A: Connie, You did not supply all that info....smile. So, I assume you mean the large copper pipe ...
|
| A/C unit not cooling | 8/17/2009 |
Q: .. I have a Sears High Efficiency Central Air Condition, Model #769-81602. The unit is having ... A: Jim, If all the vents in the house are open and you have a clean filter in, let it run for ten ...
|
| Amana problem | 8/17/2009 |
Q: We have an Amana furnace that is about 7 yrs old and isn’t working. We had our vents cleaned last ... A: Nicole, Unless it is a fluke, I would suspect the duct guy did something unintentionally ( I would ...
|
| No air flow when a/c comes on | 8/17/2009 |
Q: my central air outdoor unit comes on like it should when the thermostat clicks it on but I'm not ... A: Chris, First thing to try is put it in heat mode and call for heat and see if the blower comes on ...
|
| Newly Installed Electric Furnace and Air Conditioner | 8/17/2009 |
Q: I live in a 20-year old, 3 story 1300 sq. ft. condo in Cincinnati, OH. (It has a walk-out basement, ... A: Connie, Sorry for the lack of professional help you received. It would not matter how it shorted ...
|
| Newly Installed Electric Furnace and Air Conditioner | 8/17/2009 |
Q: I live in a 20-year old, 3 story 1300 sq. ft. condo in Cincinnati, OH. (It has a walk-out basement, ... A: Connie, If you had a 20 year old payne, then the duct work must have been ok for it, to last that ...
|
| air conditioner problem | 8/17/2009 |
Q: my home air conditioner unit only shuts off for 3 minutes at a time, then runs for at least 10 ... A: Jerry, If you have an old mercury bulb tstat, the anticipator might need to be set or it is worn ...
|
| Central Air Conditioner Not Working? | 8/17/2009 |
Q: Today we noticed that our house was no longer getting cool. We are "total electric." We have an ... A: Carista, The cap could still be bad, even without visual signs, but it sounds like the motor is ...
|
| ac/furnace | 8/16/2009 |
Q: We have a Luxaire furnace that we believe is original to our 1977 house we bought 3 years ... A: Kim, Yes the blower motor of that age is an oil port motor. The problem with doing it yourself is ...
|
| heat pump and air handler | 8/16/2009 |
Q: ..we are considering replacing a 31 year old air handler. our american standard 21/2 ton heat pump ... A: Jay, Personally I would replace it due to age, even though it will do the same job as a new one. ...
|
| split system ac unit | 8/16/2009 |
Q: recently installed new condenser outside,2 1/2 ton,transformer has tripped several times,it also ... A: Chuck, Who the heck is working on your equipment....a roofer. Sounds to me like the old unit ...
|
| placement of heat pump return air vents | 8/16/2009 |
Q: I have 2 return air vents for my heat pump. One at floor level in the hallway wall and one in the ... A: Robert, That will not make any difference in your bill. It sounds like you have one of two ...
|
| zone cooling | 8/16/2009 |
Q: Have a Bryant 4 zone perfect plus. It will not respond to inputs. Two zones may be shut out or hold ... A: Randy, Sounds like there are some crossed wires to the zone dampers. Here is the easy way to fix ...
|
| 3 year old tempstar evap coil | 8/10/2009 |
Q: I purchased and had installed a brand new Tempstar heat pump / AC unit three years ago when I bought ... A: Justin, Yes you are. Any tech should have come, gauged up and started the system. If there is a ...
|
| air handler problem | 8/10/2009 |
Q: About 3 years ago I had a problem where the outside air compressor was working (and all iced up) but ... A: Paul, You have either and air flow or refrigerant flow problem. All vents open? Clean filter? ...
|
| a-coil selection | 8/10/2009 |
Q: Is it ever okay or desirable to mis-match the a-coil and the condenser unit? Long story ... A: Chris, The only time to run a larger coil is with a heat pump using the new r410a refrigerant and ...
|
| Miller Outdoor Heat Pump Unit | 8/10/2009 |
Q: The fan to my outdoor unit will not turn on. You can hear power going to the unit, but nothing is ... A: Jenny, Well if you have a new defrost control board, then it is probably the motor or the run ...
|
| air conditioning/furnance | 8/9/2009 |
Q: Sometime this afternoon our house started heating up and we found later that while it sounds like ... A: Brian, sounds like your indoor coil is frozen. So, turn off the system switch and turn on the fan ...
|
| t stat question | 8/8/2009 |
Q: I have a trane heat pump unit. I think it has a 15kw heat strip in it. I have a hunter touchscreen ... A: Travis, The first thing to do is have a tech gauge up and probably adjust your refrigerant level. ...
|
| Fan motor not running | 8/7/2009 |
Q: I have a 2 1/2 ton Lennox that is making a hissing noise down around the base of the unit and the ... A: John, What was done about the line? The hiss can be one of 3 things. First, a leak, which if it ...
|
| Quietest Attic Air Handler Installation | 8/7/2009 |
Q: Good Morning, I will be installing a split geothermal system in a ~ 1500 square foot 1928 colonial ... A: John, In theory it sounds nice but air does not move like water. It actually needs the back ...
|
| Furnace door won't stay shut | 8/7/2009 |
Q: I have a mystery regarding the front panel/cover on my furnace. My furnace (air conditioning) has ... A: Jesse, Your furnace might have these 1/4 square black pieces where the doors come together with a ...
|
| blower motors | 8/6/2009 |
Q: We recently replaced our blower motor in our gas furnace with one identical to the old one. Here are ... A: Chanda, On the small plate that you remove to get to the wiring is a schematic, that shows what ...
|
| Heat pump package unit | 8/6/2009 |
Q: We have a 22 yr. old 3 ton Rheem or Rudd heat pump package unit that we're looking to replace. What ... A: Kim, Stay away from the Ammana. You got over 2 decades with the prior equipment, why change that. ...
|
| New AC unit compressor on and off while outside fan running | 8/6/2009 |
Q: We purchased an AC unit of Kenmore model H4A448GKB100 in Jun 2008 and Sears’s contractors ... A: Sam, As you have found out, it is not the equipment but the installation that is the problem. In ...
|
| Carrier heat pump | 8/6/2009 |
Q: My a/c unit is not cooling properly. The condenser is running and the fan seems to be running. The ... A: Debora, do this test. Remove the air filter ( just for this test ) have every air vent in your ...
|
| heat pump and air handler | 8/5/2009 |
Q: ..we have a 5 year old 10seer american standard 2 and 1/2 ton heat pump, that runs good. our air ... A: Jay, Although as of January they will no longer produce equipment using R22, the refrigerant and ...
|
| blinking amber light | 8/5/2009 |
Q: Concerning an american standard freedom 80 single stage gas furnace...there is an amber blinking ... A: Patty, If you remove the door on the blower compartment( there are two doors, one for the burner ...
|
| AC CONDENSATE | 8/5/2009 |
Q: Recently I noticed water dripping from the RELECTIX insulation that covers the ducts and coil that ... A: Joe, Whenever a system is zoned, as each zone is satisfied and the damper closes, there is a large ...
|
| heat pump low voltage | 8/4/2009 |
Q: i have just installed a new goodman 3ton heat pump with matching coil to a intertherm down draft ... A: Scott, TSTAT FURNACE HEAT PUMP R=RED R=RED R=RED C=BLACK ...
|
| Return air grill condensation | 8/4/2009 |
Q: Recently I have noticed that when I get up in the mornings my return air grill is dripping with ... A: Mick, It is because of humidity and dew point, the temp drops just below it at night because of ...
|
| cooling problem | 8/4/2009 |
Q: I been having a problem with cooling, I recently graduated from an AC refrigeration school but, I'm ... A: Robert, What is you dry bulb return air temp and what is your liquid temp? I dont know where you ...
|
| evap coil drain | 8/3/2009 |
Q: John, Finally lit off our split system (Frigidaire) AC unit to temper the summer heat. The unit is ... A: Tim, Yes those things happen. If you fill the drain pan with water with the unit off, you should ...
|
| AC unit Dead | 8/3/2009 |
Q: 2yr 13 Seer Johnson Fraser(YORK International) AC unit dead.The fan outside will not come on. It is ... A: Katilina, Phone any company that is reputable for the work. It wont be just the compressor, if it ...
|
| AC CONDENSATE | 8/3/2009 |
Q: Recently I noticed water dripping from the RELECTIX insulation that covers the ducts and coil that ... A: Joe, First you say zones? Do you mean area's? Zoning means that those ducts have dampers that ...
|
| wet spots on exterior stucco | 8/2/2009 |
Q: I just recently purchased a 7 year old house. I noticed that whenever I run the AC unit, I notice ... A: Rob, If the secondary pipe does not exit the structure it should be finished. I don't know where ...
|
| New AC Unit dead after 2 days - same problem as before. | 8/2/2009 |
Q: I recently had my entire unit replaced through a home warranty claim. According to the tech, the ... A: Kirk, I can almost promise you are out of or low on freon. Any " tech " that has trouble sealing ...
|
| Water pouring out of furnace | 8/2/2009 |
Q: We just bought a new house in MD and when we run the AC water flows out from below the furnace. Is ... A: David, There are a couple reasons for the water. One would be a clogged drain from the drain pan, ...
|
| Central Air unit | 8/1/2009 |
Q: Yesterday I heard water rushing and discovered water coming out of my Central Air Unit (Goodman ... A: Angie, The pan can be purchased by itself. It can also be repaired, depending on where it is ...
|
| Isolating 24v transformers | 8/1/2009 |
Q: Was just up in your neck of the woods (Portland) this week ...guess you've been busy with the heat ... A: Mike, First of all, yes that is what is called a peanut relay. You had indicated you wanted the ...
|
| Isolating 24v transformers | 8/1/2009 |
Q: Was just up in your neck of the woods (Portland) this week ...guess you've been busy with the heat ... A: Mike, Yes if the de-humidifier has its own 24 volt system you will need to isolate it. The ...
|
| AC Unit | 8/1/2009 |
Q: Bought a new house 1 yr ago. Turned on the AC in the house for the first time this summer and it was ... A: Matt, Compressor??? What compressor? In your unit? To be honest 300 sounds too cheap. If you ...
|
| Unico loss of cooling | 8/1/2009 |
Q: I am in the construction business and ask this question with a little knowledge of things. We have ... A: Dana, I actually guessed that part, kinda. But I am familiar with unico and do not know what to ...
|
| sp80 tampstar | 7/31/2009 |
Q: the fan doesn't come on went you turn the ac or heat on. i have power A: James, Are you talking about the blower? It is in the furnace and moves the air in the house. If ...
|
| Air conditiner warranty | 7/31/2009 |
Q: Carrier 2-ton residential ac model 38ckc024340. Installed 4 years ago for use in our small office ... A: Judy, Warranty will not cover new unit. And if you have had an electrical burn it could cost as ...
|
| AC Unit | 7/30/2009 |
Q: Bought a new house 1 yr ago. Turned on the AC in the house for the first time this summer and it was ... A: Matt, It is very very rare for the outdoor coil to have a leak. I have to assume he came out, ...
|
| LENNOX HP CONDENSER NOT RUNNING | 7/30/2009 |
Q: i have an 11 year old Lennox heat pump. About a week ago, the blower motor burnt up so we replaced ... A: Cassie, You should check the breaker for the outdoor unit. There also might be slow blow fuses in ...
|
| Clean an A-Coil | 7/30/2009 |
Q: I know that you can trap the freon in the condensing unit so you can cut the lines and remove the ... A: William, You should be bleeding nitrogen when brazing and I would use silfloss or silbraze, then ...
|
| GOODMAN AC HANDLER BLOWER INOP AT TIMES | 7/30/2009 |
Q: MR. BORGMAN, I HAVE A 2 STORY HOUSE WITH 2 SEPARATE AC/HEAT SYSTEMS(I BELIEVE THE AC HANDLER #'S ARE ... A: John, If that furnace has a deadman switch ( when you open the blower door it pops out and kills ...
|
| Portable air conditioner shakes and sputters | 7/30/2009 |
Q: I have a portable sunpentown air conditioner, and it does this new thing I haven't seen before. In ... A: Carrie, Well, there are only a couple moving parts so it has to be either the compressor motor or ...
|
| Installation of Fan Timer Control Board | 7/30/2009 |
Q: I need to replace the fan timer control board in our Comfortmaker HVAC system. The board is ... A: Sam, No hidden power issues with that. Most boards are a wire for wire change, but some boards ...
|
| Compressor cuts out | 7/30/2009 |
Q: I have a 10,000 btu window unit that usually cools my entire (small) apartment. When it gets around ... A: Joseph, There is not a lot you can do except to position a mist head on a garden hose and have it ...
|
| new ac | 7/29/2009 |
Q: I am an ac dummy. My home ac unit just went out-compressor I guess. It was 26 years old and just ... A: Stephanie, Since I do not know if the indoor air handler is a furnace ( electric or gas ) or what ...
|
| AC system keeps breaking down | 7/29/2009 |
Q: I have a 5 year old home/AC units. The upstairs unit has been breaking down for 1 year. 1.5 years ... A: Stephanie, John borgman here, I got this out of our question pool. If it was a return air vent ...
|
| hvac first floor units | 7/28/2009 |
Q: i have a 1940's 3300 sqft property which i am renovating in Houston TX and a hvac rep has ... A: Tim, As far as building it in, just make sure that whatever is covering the furnace doors can ...
|
| Clogged AC drip pan | 7/28/2009 |
Q: Can i fix a clogged drip pan on my AC unit relatively easy or do I need to call a professional? ... A: Sue, it depends on how the coil was installed. If it is a cased coil, with a factory door, and it ...
|
| Filter | 7/27/2009 |
Q: Our air conditioner has frozen up and I removed the panel to see what things looked like in ... A: Cammy, If there is no filter in the furnace or the return air grill, then your indoor coil and the ...
|
| York Heat Pump, Emergency Heat Light | 7/27/2009 |
Q: Good Day: Thank you for your time! We have an old (at least 15 year old) York heat pump with a ... A: Brad, you will need a tech to come out. Those Yorks are hard enough for a tech to work on. It ...
|
| heat pump | 7/27/2009 |
Q: For a long time I would have to turn the thermostat on and off several times for it to come on. I ... A: Tedd, Get a service tech out there before you burn everything up. You cannot let the smoke or the ...
|
| Window Air Conditioner ducting to furance ? | 7/27/2009 |
Q: I live in Nova Scotia, Canada. I currently have a forced hot air furnace for heating my home. The ... A: Larry, you wouldn't get that much done by that method. You would be better off, just mounting a ...
|
| rewiring 3 terminal capacitor to 2 terminal capc. | 7/27/2009 |
Q: I replaced the condenserfan motor which comes with 7.5/370v run capacitor that has two terminals ... A: George, The two brown wires are for you run capacitor, which should ALWAYS be replaced when ...
|
| hvac first floor units | 7/27/2009 |
Q: i have a 1940's 3300 sqft property which i am renovating in Houston TX and a hvac rep has ... A: Tim, If you asking if a upflow furnace in the basement, to service that floor and the main floor ...
|
| INOP Central Air | 7/26/2009 |
Q: I have a Central air unit that is working but not cooling . the unit outside is on the one in the ... A: Nelson, First you need to check the air filter and for this test, go ahead and remove it from the ...
|
| ac intake (return) | 7/26/2009 |
Q: We have a 4 ton central ac and are going to have a 5 ton installed (which was determined by a load ... A: Connie, First increasing by a ton is quite a bit. Was this calculated by manual J, room by room ...
|
| Rudd ac unit | 7/26/2009 |
Q: Honeywell FocusPro 5000 set at 70deg. and inside temp. got up to 84deg. yesterday. Fan outside just ... A: William, Sounds like you are talking about the condenser fan motor and if it is turning slowly it ...
|
| Air Flow to a Bedroom | 7/26/2009 |
Q: When I had my system installed several years ago, I asked for a little bit of increased air flow to ... A: Brian, Probably the easiest way to do what you want is to blank off the collar coming from the ...
|
| Bryant Air Conditioner Unit Installed 1992 | 7/25/2009 |
Q: Mr. Borgman, I have a Bryant heating and air conditioner system in my house. It was installed when ... A: Lewis, So was this tech from the same company? I am still not comfortable with the 30 day thing. ...
|
| refiregrant leak | 7/25/2009 |
Q: I recently found out I had a leak in my system. The system is a year old and I recently had a coil ... A: You didn't tell me it was a R410a system. But the numbers you sent me tell me so. Problem is that ...
|
| ac ceiling vent | 7/25/2009 |
Q: We are looking at buying a house and the is one annoying little problem I want to be able to fix to ... A: Kate, OK, here is what is up there, when you take the two screws out of the louvered register ...
|
| Air Flow to a Bedroom | 7/24/2009 |
Q: When I had my system installed several years ago, I asked for a little bit of increased air flow to ... A: I am thinking, that they on purpose ran that run straight from the plenum to give you plenty of air ...
|
| Air Flow to a Bedroom | 7/24/2009 |
Q: When I had my system installed several years ago, I asked for a little bit of increased air flow to ... A: Brian, Was that where the original run was from? I have never heard of 4" unless it is a high ...
|
| AC won't cool/ Freon Leak/Condensing Coil | 7/24/2009 |
Q: About 5 days ago, our air conditioner quit cooling the house. We would set it at 76 and the house ... A: Sally, Hi, me again. How did he show you the leaks? If he showed you with an electronic ...
|
| duct cfm | 7/24/2009 |
Q: I was the one asking about charging a sysyem with refrigerent, and yes I'm in thr field, currently I ... A: Brian, Practically you cannot. There are some pretty heavy mathematical equations for that, but ...
|
| Whole house fan | 7/24/2009 |
Q: Our whole house fan went out after 18 years so we replaced it with a flow master we purchased from ... A: Mary, I really do not know what the right side means. But if you are having an issue with a Home ...
|
| refiregrant leak | 7/23/2009 |
Q: I recently found out I had a leak in my system. The system is a year old and I recently had a coil ... A: Vadim, If it holds at 400 psi, then there is not a leak where they are testing. My question would ...
|
| removimg a gas furnace | 7/23/2009 |
Q: I need to remove a furnace and cap off a gas line in order to have a heat pump/air conditioning unit ... A: Larry, No, you covered everything. Actually you might get a little smell, but you can dump a ...
|
| PAYNE model PA10, have to keep replacing fuse | 7/23/2009 |
Q: i bought my home in 2003 and had continuous problems with the air conditioning unit since the ... A: Joy, If you are having the same problem as you had with the old unit you had replaced, then the ...
|
| Armstrong electric furnace | 7/23/2009 |
Q: I recently purchased a house with an Armstrong EFC12SAA electric furnace. There is a whole house ... A: Christopher, If the coil for the humidifier is 24 volts, then you want to wire one side to 24v ...
|
| contactor noise | 7/23/2009 |
Q: The contactor at the outdoor unit growls momentarily before closing. I have 27 volts coming in to ... A: John, I am trying to teach you proper electrical troubleshooting , so you can do just that. You ...
|
| sizing house | 7/23/2009 |
Q: I was the one asking about charging a sysyem with refrigerent, and yes I'm in thr field, currently I ... A: Brian, For that, the first thing you need to do is get Manual J, either the book or computer ...
|
| air con stopped working outdoor unit | 7/22/2009 |
Q: i have a fuji electric rom-19ua2 outdoor unit and it has stopped working , the fan dont turn and ... A: Jim, I am afraid you are going to need a service tech, Jim. The sound could be the overload ...
|
| contactor noise | 7/22/2009 |
Q: The contactor at the outdoor unit growls momentarily before closing. I have 27 volts coming in to ... A: John, You mean you placed your lead not leads. And had the other lead where? Also is it a NO or ...
|
| air conditioning | 7/22/2009 |
Q: I have a 3 year old ameristar furnace by american standard and an american standard central air ... A: Shawn, OK, here is what we do next. turn off the power to the furnace either at the breaker or if ...
|
| contactor noise | 7/22/2009 |
Q: The contactor at the outdoor unit growls momentarily before closing. I have 27 volts coming in to ... A: John, So the low pressure switch on that unit is a normally closed?? You said it does not open ...
|
| Bryant Air Conditioner Unit Installed 1992 | 7/22/2009 |
Q: Mr. Borgman, I have a Bryant heating and air conditioner system in my house. It was installed when ... A: Lewis, I almost hate getting ones like this......You might want to find a real tech to work on ...
|
| Freon leaking | 7/22/2009 |
Q: John, I asked a company to do my A/C tune-up today. The tech told me the freon pressure is low and ... A: Yong, The guy is not only very bad at his job, but either does not know what the montreal Protocal ...
|
| Central Air in a Mobile Home | 7/22/2009 |
Q: I hope this is not a repeat question but i have searched far and wide and can't find an answer that ... A: Matthew, There is supposed to be a " cross over duct " that connects the 2 sides of the mobile ...
|
| Air Conditioning Won't Cool | 7/21/2009 |
Q: Our house was built in 1998, apparently the builder put smaller units than is recommended. However, ... A: Erin, Yes it should work better. First I think that a cooler supply temp can be obtained, if I ...
|
| HVAC New Home | 7/21/2009 |
Q: Greetings: We are building a new home, 3 BR 2-1/2 BA, in Kitty Hawk, NC. Approx. 1900 sq. ft. ... A: Denise, With no attic the power exhaust fan is not an option. Sorry if what I said was ...
|
| Freon leaking | 7/21/2009 |
Q: John, I asked a company to do my A/C tune-up today. The tech told me the freon pressure is low and ... A: Yong, I apologize for the company that has that tech working there, you might want to phone them, ...
|
| Vert or Horz loop | 7/21/2009 |
Q: John, I appreciate your time. I will try to make this short. Dirt is dug on my property and I have a ... A: Chip, No I know of no reason for not going horizontal and respectfully would take a lot more work ...
|
| TRANE Problem?? | 7/21/2009 |
Q: We have a 1-2 year old Trane AC and a programmable thermostat. Everything worked great yesterday and ... A: Alicia, Call your local Trane dealer asap, Alicia. That Trane has a 5 year warranty at the very ...
|
| follow-up of your ans. to me of 7-13-09 | 7/21/2009 |
Q: Would your answer you gave be the same if the heat pump Would your answer be the same as to ease ... A: Mel, The evap. coil has nothing to do with the water source for the outdoor unit, unless you are ...
|
| HVAC New Home | 7/21/2009 |
Q: Greetings: We are building a new home, 3 BR 2-1/2 BA, in Kitty Hawk, NC. Approx. 1900 sq. ft. ... A: Denise, Well the second guy does not know how zoning works and if you use the first guy hopefully ...
|
| Vert or Horz loop | 7/21/2009 |
Q: John, I appreciate your time. I will try to make this short. Dirt is dug on my property and I have a ... A: Chip, I guess it is a good thing I am an expert, you gave no clue as to what you building...lol ...
|
| Ac problems | 7/20/2009 |
Q: My outdoor ac unit stopped running a couple days ago and after doing some research we decided to see ... A: T, You need to put an amp probe on the motor and see if the amp draw climbs along with the fan ...
|
| Ac problems | 7/20/2009 |
Q: My outdoor ac unit stopped running a couple days ago and after doing some research we decided to see ... A: T, It sounds like you wired it wrong and got two of the leads reversed, although that wouldn't ...
|
| flame sensor location | 7/20/2009 |
Q: Where is the flame sensor located on a 10 ton gas pac lenox ac unit A: David, John Borgman here, I got this question from our question pool. I am assuming you are a ...
|
| Carrier control board | 7/20/2009 |
Q: I have the info you ask for on the control board, remember I bough a control board with only one ... A: Robert, The BDP part number is .... CES0110057-02 If you do run across a situation where the ...
|
| home a/c unit on roof | 7/20/2009 |
Q: fan motor seized, got it replaced. unit then only cooled for about 20 min. was told compressor is ... A: ask your other person what an overload devise is and how it works. It is for emergency only and ...
|
| thermostat | 7/20/2009 |
Q: i have an Evcon unit about 2 1/2 years old. today my thermostat started blinking the following ... A: Ken, I do not take private questions and I did not know Evcon made a thermostat and I have no idea ...
|
| HVAC sealed combustion return air | 7/20/2009 |
Q: How close can a cold air return be on a sealed combustion unit? A: Brad, Are you talking about one that gets its combustion air from outside or in the room it is in? ...
|
| water leaking in basement around heater / ac unit | 7/19/2009 |
Q: Why is water leaking around our propane heater /AC unit?? A: Lynne, It could be a number of things, from a clogged drain line, to a faulty condensate pump, to ...
|
| wiring | 7/19/2009 |
Q: hi john im not sure weather u can help but its worth a try i can build small windturbines with no ... A: Fred, Are you watching the OPEN? Would love to come visit our mother country someday. There are ...
|
| iced coil | 7/18/2009 |
Q: Today I discovered that my indoor coil of my central air unit was heavily iced after running for a ... A: Vadim, Ther are 2 things that will cause the indoor ( evaporator ) coil to ice over. Low indoor ...
|
| humidity | 7/18/2009 |
Q: I noticed a question about cfms and you said that in a humid climate a small amount of cfm would be ... A: gerald, I don't think you read what I wrote correctly, if it was me. I answer hundreds of ...
|
| air conditioner split system | 7/18/2009 |
Q: I have a Coleman Evcon 3 ton R22 split system unit, this system is 10 years old. It is not cooling ... A: Steve, I would be glad to help you, but you need to give me better measurements. I need the ...
|
| home a/c unit on roof | 7/18/2009 |
Q: fan motor seized, got it replaced. unit then only cooled for about 20 min. was told compressor is ... A: Mike, 10 years is the cut off to look at a case by case business, but doesn't mean it can not be ...
|
| heat pump gets ice | 7/18/2009 |
Q: I answer on allexperts in 5 other categories, but am not an expert on HVAC. My heat pump worked fine ... A: Dave, Probably Dave. Low air flow or low refrigerant flow are the 2 reasons for that. With the ...
|
| imbalance of air flow | 7/18/2009 |
Q: we have a couple vents that are blowing very hard and barely any flow going to the rest of house. I ... A: Robert, You really need a tech there to get that straightened out. Air does not flow like water ...
|
| multimetering | 7/18/2009 |
Q: first it seems like my t-stat when i change something is turns off and then maybe turn back on, like ... A: Kenny, Your step down transformer gets 120 volts from the grid and supplies 24 volts to the hvac ...
|
| a/c compressor | 7/18/2009 |
Q: unit o/s 21/2 ton, air handler 3 ton i notice the o/s unit starts without the compressor but ... A: Len, You cannot change the motor, first they all come in the same rpm 1075 and if you reduce the ...
|
| AC return air location | 7/17/2009 |
Q: I am trying to determine is the building dropped ceiling hot air return vent is in the right ... A: Debbie, Since the A/C was not sized for the heat from a server room, no. You should let the spot ...
|
| AC not removing humidity | 7/17/2009 |
Q: John, I have a 20 year old Trane AC unit which recently had 3lbs of freon added. After that for ... A: Robert, What does high amps mean? There is a clearly marked rating on the name plate of the ...
|
| thermostat not shutting off AC | 7/17/2009 |
Q: Two days ago had the outdoor condenser of refrigerated AC moved to roof due to a coolant leak ... A: Jeannine, Why in the world did you move it to the roof...because of a leak?? Never heard of such ...
|
| Tuneup on a AC Unit | 7/17/2009 |
Q: I bought a house 2 years ago and the ac unit is 8 years old, I am looking at getting a tune up on ... A: Marc, You need to have a tune up and I would be surprised if the contactor is still good, but ...
|
| propane heater | 7/16/2009 |
Q: My neighbors burner on her heater for her house seems to plug up with some sort of foreign stuff. ... A: Pete, No, propane is usually as clean as natural gas. The burner gets plugged either by a not so ...
|
| AC compressor will not shut off | 7/16/2009 |
Q: I have a 10 year old, 3 ton, electric AC unit. I had a small leak in the outside unit about a ... A: Krista, It is one of two things. Less likely your low wiring is either not wired correctly at the ...
|
| clicking in our central heating and air | 7/16/2009 |
Q: I read a questions from someone else that sounded alot like my problem so here goes. Our mobile ... A: Sue, You are going to have to provide me with more info than that. Where is the clicking? What ...
|
| gas heating | 7/16/2009 |
Q: I have a 24 x 30 garage with 9' ceilings that I want to heat with natural gas. Could you please tell ... A: Robert, Yes and that is assuming you have very little or no insulation everywhere else besides the ...
|
| Wiring new Condensor fan motor. | 7/16/2009 |
Q: I came across this forum as I was digging through information on replacing the condenser fan motor ... A: Kevin, Do not run it that way you will burn up the motor. You do not have the run cap working and ...
|
| gas heating | 7/15/2009 |
Q: I have a 24 x 30 garage with 9' ceilings that I want to heat with natural gas. Could you please tell ... A: Robert, It depends on the insulation and if you have a standard opening garage door for the size ...
|
| Wiring new Condensor fan motor. | 7/15/2009 |
Q: I came across this forum as I was digging through information on replacing the condenser fan motor ... A: Kevin, Actually it is refreshing to get more than " my a/c quit whats wrong...lol" The first ...
|
| hvac air flow | 7/15/2009 |
Q: 3rd yr in a row my hvac runs all day til evening, then sweats & leaks under coil & sometimes after ... A: Jen, I understand your frustration, believe it or not I feel the same way on calls I go on and ...
|
| hvac air flow | 7/15/2009 |
Q: 3rd yr in a row my hvac runs all day til evening, then sweats & leaks under coil & sometimes after ... A: Jen, You only gave me a rating of 8 on knowledge?
|
| A/C frozen coil/bad compressor/TXV | 7/14/2009 |
Q: We have a Trane heat pump, new 3.5 years ago (installed to heat/cool an addition to house). Two ... A: Sybil, First, In an air conditioner, the indoor coil sits in the air stream and liquid refrigerant ...
|
| increasing hvac air flow on existing unit | 7/14/2009 |
Q: I just purchased a single story home 1700 sq ft with a 5ton unit in the attic and 5ton condensing ... A: Spencer, I need more info to help..1000 cfm return???? I need to know the return air plenum size, ...
|
| Location of return air duct. | 7/14/2009 |
Q: My house currently has 8 (13.75" x 7.75") return air ducts, 4 each on the first and second floor. My ... A: Cutting a hole in it will not increase its size!!! And if your duct work collapses now, more air ...
|
| Location of return air duct. | 7/14/2009 |
Q: My house currently has 8 (13.75" x 7.75") return air ducts, 4 each on the first and second floor. My ... A: Kim, First, how did your old equipment do before it failed? Second if you increase the tonnage ...
|
| Trane Air conditioner unit | 7/14/2009 |
Q: I broughta Trane 2TTX5030A1000AA heating and airconditioner unit from a local company in arkansas. i ... A: I am assuming you might have a duct problem, as, the dripping copper pipe says that the air flow and ...
|
| Bryant central unit-Ruud outside fan | 7/13/2009 |
Q: Outside fan works but I do not know how to tell if the air is warm enough coming out of it off the ... A: Don, No, it sounds like you are describing a problem with the blower motor. Do Not turn it on ...
|
| HVAC works, inside fan motor will not come on | 7/13/2009 |
Q: I recently went into the furnace, pulled the covers and changed the filter only. Put the covers back ... A: Steve, The outdoor unit does not blow air inside, it moves refrigerant inside. The motor below ...
|
| Freon Problem? | 7/13/2009 |
Q: Hey I have a VEXAR Coil unit heating my mobile home. I paid a guy $100 to come out and fill my unit ... A: Chad, I don't have a clue what the guy did I was not there. It is not filled inside the house. ...
|
| Trane Air conditioner unit | 7/13/2009 |
Q: I broughta Trane 2TTX5030A1000AA heating and airconditioner unit from a local company in arkansas. i ... A: I am sorry to inform you that the tech is lying to you. There is no physical way your equipment ...
|
| Settings for 2 level home? | 7/13/2009 |
Q: I have a general question about cost control in a 2 level house. I live in Arizona and currently we ... A: Alex, The first thing you should consider is a tstat controlled power attic fan, if you have an ...
|
| Freon Loss | 7/13/2009 |
Q: I believe that my unit is a heat pump, as it provides my heating and air conditioning. My question ... A: Rick, You need to crawl under your home and secure the cross over duct work, it is flex duct and ...
|
| Freon Loss | 7/13/2009 |
Q: I believe that my unit is a heat pump, as it provides my heating and air conditioning. My question ... A: Rick, There is no such thing as magic, a phrase from my engineering teacher of old. Why would you ...
|
| rv a/c no leaking water on outside of trailer | 7/13/2009 |
Q: my rv a/c is not leaking water on the out side of the trailer what could be the problem ANSWER: ... A: There are a lot of things that can cause it to not condense water from the air, including a little ...
|
| Maytag fridge cooling fan issue | 7/12/2009 |
Q: I have a fridge (Maytag MTB2456gew) that started not working properly, so I tried to troubleshoot. ... A: Mark, FYI, I am just an expert volunteer on here. Looking to build my portfolio for making this ...
|
| Ruud air conditioner/blower issues | 7/12/2009 |
Q: I have a Ruud model #UGDA-12EA-ER furnace with outside air conditioner unit. I turned the AC on this ... A: Jerry, Pull the front door from the furnace. To the right of the vent pipe there is a brown door ...
|
| refrigerant escaped from a/c. | 7/12/2009 |
Q: We have separate Command a/c for 1300 sq. ft. condo unit in South Florida, built 1991. Responding to ... A: Mel, Did He show you the leak? A coil leak be it indoor or out, can easily be repaired. I have ...
|
| AC fan stays on when AC is off | 7/12/2009 |
Q: Replaced an old t-stat recently with a new programmable t-stat (ritetemp model 6025). Initially had ... A: Kevin, http://www.ritetemp-thermostats.com/6025.html Unless there is a program set up for the fan ...
|
| Filter turning black | 7/11/2009 |
Q: I have an electric heating and cooling system and about a month ago we noticed that our air ... A: Toni, It is not coming from your furnace. It is coming through the duct system. Could be a duct ...
|
| air handler bower motor | 7/11/2009 |
Q: I recently change my fan control board for my inside AC unit. The original circuit board had a place ... A: Robert, If you get me the product code number off that unit I can get you the part number for the ...
|
| two-stage vs. single-stage A/C | 7/10/2009 |
Q: We are looking to replace our A/C and furnace. One guy told me that a two-stage A/C is more ... A: Claire, It really depends on your duct system and that is something that the contractors should be ...
|
| Getting heat in summer | 7/9/2009 |
Q: I have a GE heat pump/ac system at our beach home. When we leave the area I turn off the system at ... A: Rob, It sounds like the outdoor unit is staying on, maybe the contactor is frozen shut. It does ...
|
| Installation of AC/Heat | 7/9/2009 |
Q: Our heat pump went out last year and we are currently getting bids on a replacement (regular AC/Heat ... A: Jeri, The tax credit is very high for 410a high seer rating. I agree with both carrier and ...
|
| American Standard AC frosting at gasline service valve | 7/9/2009 |
Q: Model 7A0018-042A. This is a new behavior on a 6 yo system. When the unit starts, the frost appears ... A: Rod, First lets assume that it was charged correctly and no leaks. Change your air filter or pull ...
|
| two-stage vs. single-stage A/C | 7/9/2009 |
Q: We are looking to replace our A/C and furnace. One guy told me that a two-stage A/C is more ... A: Claire, Go with the Bryant which is a carrier product. The outdoor high seer unit is so quiet you ...
|
| Geothermal HVAC systems and problems | 7/9/2009 |
Q: I am considering replacing my nineteen year old HVAC system with a geothermal system. Would you ... A: Bob, First downside is there will need to be a back up heat source unless you don't mind waiting a ...
|
| air handler bower motor | 7/9/2009 |
Q: I recently change my fan control board for my inside AC unit. The original circuit board had a place ... A: Robert, At the very least you need to change to high speed, right now with a dirty filter you will ...
|
| Squeaking noise from AC | 7/9/2009 |
Q: I have a 5 year old Carrier Central AC. It runs OK, but about 30s after the AC stops, it give out a ... A: That could be done by replacing the external equilizer tube on the metering device, which means a ...
|
| charging system | 7/9/2009 |
Q: I was the one asking about charging a sysyem with refrigerent, and yes I'm in thr field, currently I ... A: Brian, Cool. The most important thing to do first is pressure test with nitrogen after all joints ...
|
| AC evaporator & filter | 7/9/2009 |
Q: 2.5 yr old Summit evaporator leaking needs replacement - rest of system is Carrier - Houston, TX ... A: Joseph, They are wrong. Not only have I done many without a problem but they can put wet rags or ...
|
| hvac fan issue follow up | 7/9/2009 |
Q: the fan starts and stops all of the time. the hvac side the the t-stat is off and the fan is set to ... A: Curt, I missed the comment about the fan switch in the on position....my bad. I might need to ...
|
| FUSE | 7/9/2009 |
Q: I HAVE A RUUD 96% FURNACE, I JUST IN STALLED IT AND WHEN THE SAFTY SWITCH IS PRESSED THE POWER ... A: Cliff, Unhook the low voltage wires from the board , That come from the transformer. If you still ...
|
| hvac fan issue | 7/9/2009 |
Q: the fan starts and stops all of the time. the hvac side the the t-stat is off and the fan is set to ... A: Curt, Is this an old furnace? what kind? If you are willing to go through some trouble shooting ...
|
| FUSE | 7/9/2009 |
Q: I HAVE A RUUD 96% FURNACE, I JUST IN STALLED IT AND WHEN THE SAFTY SWITCH IS PRESSED THE POWER ... A: Cliff, You have a low voltage ground somewhere. Put your meter on ohms scale and with ALL low ...
|
| Fan on AC unit won't start | 7/8/2009 |
Q: The fan on my AC unit won't start up. The condenser appears to be ok, it makes the typical humming ... A: Jason, You probably need a new run capacitor, it is a duel capacitor and it also runs the ...
|
| Condensor fan | 7/8/2009 |
Q: I awoke this morning to a warm house of 76 degrees, when my thermostat is set at 68. As i began my ... A: Trey, Hi, spent some time in ft polk I know hot it can be there. Since you heard nothing run, it ...
|
| Room will not cool down below 96 degrees. | 7/8/2009 |
Q: I live in Texas. My second floor is on a separate A/C unit. I have replaced it twice because it ... A: Lynne, First lets make sure the unit is running correctly or nothing else is even worth looking ...
|
| air handler bower motor | 7/8/2009 |
Q: I recently change my fan control board for my inside AC unit. The original circuit board had a place ... A: Robert, You need high speed for cooling and a lower speed for heating. Give me model and serial. ...
|
| heating up the cold side of a heat pump | 7/8/2009 |
Q: My home uses a heat pump. In the winter the outside temp is about +32 f , here in Vancouver B.C. . ... A: John, I suppose if you built a football stadium and heated the air to 100 degrees that would work. ...
|
| Attic verses crawl space. | 7/8/2009 |
Q: I'm replacing my 15 yr old 4 ton heat pump system. My current system has the air-handler in the ... A: Sorry if I didn't make myself clear Dean, I said to put the one air handler in the space in the ...
|
| Ruud vs Carrier vs Goodman/Amana | 7/7/2009 |
Q: My 20 year old Rheem 3.5 ton and 3 ton central system are about to stop running. I live in Texas and ... A: Charlie, Carrier is also bryant day&night, and payne, all the same equipment with the same parts. ...
|
| hvac/central air | 7/7/2009 |
Q: I had a frigedaire furnace with central air unit and honeywell emm-3 minizone panel. I tried to ... A: Howie, Is this something new that has happened or an existing problem? From the small amount of ...
|
| heatpump l/v wiring | 7/7/2009 |
Q: old t.stat old furnace (electric) set up for heatpump, condensing unit being replaced its a ... A: Norm, I do not get any compensation, I volunteer before and after work. The orange wire should be ...
|
| 2 thermostats, 1 heat pump | 7/7/2009 |
Q: I'm currently renting a two story townhouse (1500 sq ft); 2 therostats with 1 heat pump. Unit ... A: John, I would hope you have a 2 zone system for those 2 tstats or it will never work right. The ...
|
| AC going on, off,on,off | 7/7/2009 |
Q: I have an American Standard split system (propane). Condenser outside the rest in the attic. 5 ton ... A: Shawn, If it is contaminated then yes, it must be removed, evacuated properly and recharged. If ( ...
|
| AC going on, off,on,off | 7/7/2009 |
Q: I have an American Standard split system (propane). Condenser outside the rest in the attic. 5 ton ... A: Shawn, Your unit is cycling on high head pressure trying to protect itself. I am sorry for the ...
|
| Fried contactor wire | 7/7/2009 |
Q: Good evening Tim, Thanks for taking the time to help me out. I own a Goodman CE 30 !HB residential ... A: Terry, John Borgman here, got your question out of the question pool. It could be both or just a ...
|
| Trane A/C compressor and coil | 7/7/2009 |
Q: .. My Trane 1.5 ton 11 seer with 2 ton cased coil 14.5 w was put in January of 2005. The coil is ... A: Martha, If they find out it is dog urine, gonna be hard to hide it will not be under warranty , as ...
|
| Air conditioner contracts | 7/7/2009 |
Q: Trying to help out my elderly father down in Fla. He is asking me about getting a service contract ... A: Matt, A service contract is a preventative maintenance agreement that usually gives a discount for ...
|
| Tech question on pressures | 7/7/2009 |
Q: I have a quick question. question is: I have a 4 ton Comfort maker air conditioner that I changed ... A: Arric, You need to check for a txv and if you have pressure on the high side and none goes through ...
|
| Central AC Unit Blower will not cycle on and off | 7/6/2009 |
Q: I have a central AC unit, a Trane 5 ton. I set my thermostat to a specific temperature. The unit ... A: Sean, It is not uncommon for a fan switch to hang up. What I recommend is to pull off the door at ...
|
| FUSE | 7/6/2009 |
Q: I HAVE A RUUD 96% FURNACE, I JUST IN STALLED IT AND WHEN THE SAFTY SWITCH IS PRESSED THE POWER ... A: Cliff, You have a low voltage ground somewhere. First thing to do if your not real good with a ...
|
| Tech question on pressures | 7/6/2009 |
Q: I have a quick question. question is: I have a 4 ton Comfort maker air conditioner that I changed ... A: Arric, I doubt it is the compressor, more likely the txv at the indoor coil. To check the txv, ...
|
| new units? | 7/6/2009 |
Q: John -we live in Phoenix & have 2 Trane heat pump units that are 13 yrs. old w/seer rating of 11/12. ... A: Marcia, You can easily get another decade from your equipment if you have some preventative maint. ...
|
| AC evaporator & filter | 7/6/2009 |
Q: 2.5 yr old Summit evaporator leaking needs replacement - rest of system is Carrier - Houston, TX ... A: Joseph, Hi, this is John Borgman, got this question out of our question pool. The coil is not ...
|
| Furnace Hums | 7/6/2009 |
Q: 1984 ICG Gas Furnace. Occasionaly thermostat calls for heat, burner comes on but when motor should ... A: Ray, No need to check the transformer, it supplies 24 volts for the entire system and is always ...
|
| T-stat temp is not met | 7/6/2009 |
Q: Im a 5 yr. tech with my class 1&2 card, residential and comercial experience. Im helping with a unit ... A: Rene' Sure I would be happy to help a tech any time you have a problem. First when asking me a ...
|
| Humidistat | 7/6/2009 |
Q: I recently moved into a house that has a carrier humidistat next to the AC control, it looks fairly ... A: Cheril, There will be a unit attached to the side of the furnace like the ones in the picture with ...
|
| Ac Thermostat-Inside House Blowing semi -cool | 7/6/2009 |
Q: We had a power outage the other day, and we had to reset the S3000 Thermostat for our A/C Unit. Now ... A: Cindy, Actually the A/C unit is on the roof. You probably have an air handler in your ceiling. ...
|
| AC not cooling enough - keeps running | 7/6/2009 |
Q: I have 11 year old 5 Ton Carrier split-unit, just got 5-lbs Freon added, at least that's what the ... A: Paul, Drive around the back of any Ma and Pa store and see equipment that is 40 to 50 years old ...
|
| heat pump | 7/6/2009 |
Q: My YORK heat pump cooling system is not working efficiantly. I have it set at 73 degrees inside and ... A: Shawn, First turn the system off and run the fan in the ON position. This will thaw the indoor ...
|
| AC not cooling enough - keeps running | 7/5/2009 |
Q: I have 11 year old 5 Ton Carrier split-unit, just got 5-lbs Freon added, at least that's what the ... A: Paul, First Paul, if it was that low and had been added to last year they did you a disservice by ...
|
| Ac Thermostat-Inside House Blowing semi -cool | 7/5/2009 |
Q: We had a power outage the other day, and we had to reset the S3000 Thermostat for our A/C Unit. Now ... A: Cindy, It sounds like your outdoor unit has stopped running, have you looked at it and checked? ...
|
| Daughter's Heat Pump | 7/5/2009 |
Q: I just wanted to update you on my daughter's heat pump. We stayed with the same company since the ... A: Dorthy, I would like to thank your appreciation, I have just written a letter to the admin. of ...
|
| trouble codes | 7/5/2009 |
Q: York Diamond 80 model G/UA036A single flashing light= Lockout-check furnace...any help with what ... A: Vince, John Borgman here, got your question from our question pool. That means your equipment has ...
|
| condenser shuts off but can restart | 7/4/2009 |
Q: Our condenser unit will shut off after a few days. The house fan, [squirrel cage] keeps running. I ... A: Jerry, If it is the high pressure switch then your problem would have gotten worse after adding ...
|
| Armstrong BCZ36B12N00A-3 condensate drain pan leaking | 7/4/2009 |
Q: My drain pan slope is towards the back of the unit now, and it overflows and leaks into the ground ... A: Chase, It just needs to be shimmed at the back, it is not usually screwed in to anything, it sits ...
|
| AC | 7/4/2009 |
Q: 2 months ago we had work done to our Goodman AC unit- The first repairman cleaned coils and added ... A: Larry, You should not have had to pay for the first call, as it did not solve anything and how ...
|
| Outside AC Unit stopped running | 7/4/2009 |
Q: We have Train XR 11 outdoor ac unit (almost 6 years old) that has been working fine until this ... A: Derek, Check your breaker and next there is a fused disconnect on the house next to the outdoor ...
|
| Starter kits | 7/4/2009 |
Q: My service tech told me the capacitor for my unit is $259.00, I found it on line for $88.00 bucks. ... A: Warren, First you must understand that a business must make money on labor and parts mark up that ...
|
| Furnace Hums | 7/3/2009 |
Q: 1984 ICG Gas Furnace. Occasionaly thermostat calls for heat, burner comes on but when motor should ... A: Ray, First thing would be to check the amp draw of the motor, it should be about 70 to 80 % of the ...
|
| rheem heat pump, outdoor fan and compressor not start | 7/3/2009 |
Q: I have a Rheem heat pump. model no is RMPC-024JAZ. when call for heat or cooling, the compressor ... A: Yves, It sounds like you either have a bad run capacitor or you have a power problem. Next to the ...
|
| Heat Pump Air Handler | 7/3/2009 |
Q: I live in the Phoenix Az area where most homes have a Heat Pump. Original Owner of my home for over ... A: Sorry...furnace means you have either a gas back up or electric, both are called a furnace, the term ...
|
| Heat Pump Air Handler | 7/3/2009 |
Q: I live in the Phoenix Az area where most homes have a Heat Pump. Original Owner of my home for over ... A: Marty, That's a good one and I can tell you right now it will take some one there with eyes on and ...
|
| Temperature of air out a supply vent | 7/2/2009 |
Q: What is the temperature at a supply vent for a home a/c? Mine is 58-59 degrees. The temperature at ... A: No, 20 degrees is the rule of thumb, you might have a dirty filter or a few ounces low on charge, I ...
|
| Carrier A/C issues | 7/2/2009 |
Q: I have a 3.5 ton carrier a/c unit that was installed three years ago. My house was built three ... A: No Jeff, the blower wheel is way heavier and has more static pressure than the fan blade. Did you ...
|
| AC Coil replacement | 7/1/2009 |
Q: The AC 1st main drain line goes to the main master bath under the sink. The 2nd drain now ... A: The first drain is the rusted drain pan and the color that the water is tells that they are correct. ...
|
| 2nd Opinion | 7/1/2009 |
Q: Greetings from another Expert at allexperts.com (I'm in the Excel and Geocaching categories)! My ... A: Two sizes copper pipe, it gives with the gauge pressure what we call superheat and sub cooling, ...
|
| Choosing a High Seer Central Air Conditioner | 7/1/2009 |
Q: John, I live in LA. Have had a contractor determine that i need a 5 ton unit. I know want to ... A: Marlon, Carrier, bryant, day&night, payne are all the same unit and all of their 410a equipment is ...
|
| 2nd Opinion | 7/1/2009 |
Q: Greetings from another Expert at allexperts.com (I'm in the Excel and Geocaching categories)! My ... A: Nathen, Something does not add up. If you have a 5 ton fan and duct system the evaporator coil ...
|
| air conditioner | 7/1/2009 |
Q: my breezair evaporater,the motor heats up after working for two hours only why.the other ... A: Mulowoka, All motors heat up, but should never heat to 30degrees c temperature rise above the ...
|
| Ductless A/C | 7/1/2009 |
Q: John, am in the process of planning our retirement home to be built in the Texas hill country. Am ... A: Ron, How well they work will depend on windows , insulation ect. If you do have a cold spell I ...
|
| Carrier A/C issues | 7/1/2009 |
Q: I have a 3.5 ton carrier a/c unit that was installed three years ago. My house was built three ... A: Jeff, Yes you have some issues, either the unit is not sized correctly and or your duct system is ...
|
| Condenser in furnace froze and now.. | 7/1/2009 |
Q: I replaced the filter in my furnace about a week ago. I usually keep the AC in the house around ... A: Gary, that is why it is frozen in your evaporator, the fan isn't running. It will use the black ...
|
| Water Source Heat Pump | 6/30/2009 |
Q: To qualify my position I have a background in A/C & Refrig. but have been out of that business for ... A: John, First thing you do is reverse the flow in heat mode and that will eliminate the metering ...
|
| Sealing return air vent | 6/30/2009 |
Q: A neighbor suggested the following tip passed on from an HVAC technician to improve cooling on the ... A: Raf, Tell your neighbor not to do that, unless somehow( and I would bet not ) they over sized the ...
|
| TXV Valve install | 6/29/2009 |
Q: I have a 3 yr old Trane unit that has been diagnosed with a bad TXV valve. The part cost is covered ... A: Bill, Standard practice is to pump the refrigerant to the other coil , lock it down and re use it. ...
|
| a/c question | 6/29/2009 |
Q: I have no low voltage to my outside unit.tried the volt test at thermostat from common to red wire ... A: Doug, Next to your furnace is there a condsensate pump, it has the pvc from the coil dumping in ...
|
| What kind of info/testing should be done to determine replacement AC? | 6/29/2009 |
Q: I live in Kansas, where it's hot and humid in the summer, dry and cold in the winter. My home is ... A: James, Take advantage of the contractors coming to your home, who can see what you have in the way ...
|
| Drip Pan on furnace | 6/29/2009 |
Q: Where is it located? Can mold be found in it? We have a new Trane AC unit and a Trane 2 stage ... A: Fred, John borgman here, got this question out of the question pool, I think in my hurry I ...
|
| is this system overcharged | 6/28/2009 |
Q: the outdoor ambient temp is 90 the indoor ambient temp is 74 the suction psi is 61 the line temp at ... A: Then everything is as it should be. Your in a high humidity area and the tstat should be set at the ...
|
| Geothermal HVAC systems and problems | 6/28/2009 |
Q: I am considering replacing my nineteen year old HVAC system with a geothermal system. Would you ... A: Bob, John Borgman here, got this out of our question pool. Lets start with if you cannot find ...
|
| is this system overcharged | 6/28/2009 |
Q: the outdoor ambient temp is 90 the indoor ambient temp is 74 the suction psi is 61 the line temp at ... A: Terry, First when asking this question the proper terminology is suction line temp and liquid line ...
|
| AC variations | 6/28/2009 |
Q: My wife has a problem with the bedroom temperature in the summer. She is complaining that our AC ... A: Alex, The thermostat controlled attic fan will do wonders for the small expense it requires, it ...
|
| A/C | 6/28/2009 |
Q: I am installing a Goodman 4 ton 16 seer and we are moving it to the back of the house and it will ... A: Frank, Your first step is to have a licenced tech come and pump the refrigerant into the outdoor ...
|
| Problem with leak checks/coils | 6/27/2009 |
Q: Last summer my air conditioning unit in my house stopped cooling. We have a home warranty, so we ... A: Fred, You should find a company that is not trying to milk insurance money. First of all, neither ...
|
| My HVAC unit sweats | 6/27/2009 |
Q: My ac sweats when its nice and hot outside which I assume is normal but when I checked it today it ... A: Johnny, Is this a heat pump in the heating mode? I am assuming so, because you cannot see the ...
|
| Air Diffusers for exposed ducts | 6/27/2009 |
Q: I live in an authentic open concept loft with 11 foot ceilings and 3 large windows along the main ... A: Mariana, Hi, John Borgman here, got this out of our question pool. The main heat gain/loss in ...
|
| can't feel air coming out of ceiling vents | 6/27/2009 |
Q: we just bought our first home yesterday and realized we can't feel air coming out of the ceiling ... A: Mary, You need to get someone to your home that knows what they are talking about to look at your ...
|
| estimated coet of ac (leak) repair | 6/27/2009 |
Q: my ac unit in attic is leaking water. i noticed when water begin dripping through ceiling in ... A: John borgman here got this question from our question pool. Whatever the cost it will be less than ...
|
| Trane Air conditioner unit | 6/27/2009 |
Q: I broughta Trane 2TTX5030A1000AA heating and airconditioner unit from a local company in arkansas. i ... A: Vernita, There really is no lemons in this industry, just poor installation and service work. ...
|
| Coleman ac unit put newfan on outside unit | 6/26/2009 |
Q: My husband just put a new fan on the outside unit and now the compressor will not kick on. what ... A: Shannon, You are going to need a service call. That does not sound good at all, the compressor ...
|
| a/c fully charged and running but not getting cold | 6/26/2009 |
Q: I am fully hvac certified I have a unit that is running and the right preasure but the suction ... A: Rev, Give me the following info and I can tell you ( if the evaporator was clogged you would have ...
|
| cooling problem/air in line | 6/26/2009 |
Q: I live in NC and have an 11 year old Carrier split system for my upstairs. Recently, the system has ... A: Greg, Sounds fishy, if there were non condensibles ( air ) in the lines it would have been fro the ...
|
| heat pump | 6/26/2009 |
Q: The air conditioner blows hot. During the winter it would work ok but the little return line was ... A: Lyle, John Borgman here, got this from our question pool. The large insulated copper line should ...
|
| hvac replacement | 6/26/2009 |
Q: We have a Carrier Weathermaker 9200 gas furnace and a 2 1/2 ton airconditioner that were installed ... A: Fran, It really all depends on how well the furnace was maintained, as far as how much life is ...
|
| drip pan for tempstar furnace | 6/26/2009 |
Q: My Tempstar furnace is leaking around the bottom of the drip pan. What do I need to do? mdl# ... A: Anthony, Usually this is a result of the coil freezing up in the indoor coil and when the ice ...
|
| A/C wont cool | 6/26/2009 |
Q: Let me preface that I'm an auto tech by profession, so forgive me if my terminology is incorrect. ... A: Dusty, Yes a little mix up.Your low side psig reading is a little low and the way to set the ...
|
| A/C wont cool | 6/26/2009 |
Q: Let me preface that I'm an auto tech by profession, so forgive me if my terminology is incorrect. ... A: Dusty, You are way low on refrigerant.Your head pressure at that ambient temperature should be in ...
|
| airconditioning problem | 6/26/2009 |
Q: My thermostat is set at 78 degrees, yet the temperature inside reaches 85 degrees. I change the air ... A: Michael, If your filter is clean and vents are open, go check the large copper insulated pipe that ...
|
| evaporator coil | 6/25/2009 |
Q: Our AC unit was no longer blowing cold air through the vents in the house, so we called a service ... A: Tiffany, You had to have been without cooling or air flow for a long time for it to have made a ...
|
| new coils or new furnace? | 6/25/2009 |
Q: We replaced or home condensor 8 years ago. Last spring or pressure was low and was checked again ... A: Lynette, John Borgman here, got this question from our question pool. Yes to can units be ...
|
| Squeaking noise from AC | 6/25/2009 |
Q: I have a 5 year old Carrier Central AC. It runs OK, but about 30s after the AC stops, it give out a ... A: What??? Tell that tech to go back to school. You are hearing the system equalize its pressures ...
|
| HVAC | 6/25/2009 |
Q: Coleman hvac,blower inside will come on and go off continuously once set temp is reached. Outside ... A: Bill, Hi John Borgman here got this from the question pool. You have an issue in the furnace. ...
|
| Brand new unit (fan runs all the time) | 6/25/2009 |
Q: Brand new 4 ton 15 seer pkg Goodman heat pump fans runs constantly. Ex: temp set 75 degrees, ... A: Yes, The fan should cycle off at the end of a call for cooling., unless the fan is set up by ...
|
| a/c has a leak how to find it. | 6/25/2009 |
Q: i have a 2.5 ton bryant heat pump that loses alot of freon. it holds 8 pounds and i put 6 pounds in ... A: Terry, Since none of the techs that were there adding freon noticed oil dripping everywhere and ...
|
| a/c has a leak how to find it. | 6/25/2009 |
Q: i have a 2.5 ton bryant heat pump that loses alot of freon. it holds 8 pounds and i put 6 pounds in ... A: Terry, That is an incredible size leak. First of all do not use it any more till you get it ...
|
| Fan/motor not running out outside TRANE unit | 6/25/2009 |
Q: This is probably a typical problem, but I thought I would ask. The inside fan is running, so power ... A: Julian, You have an upstairs and downstairs with both air handlers running off the same breaker? ...
|
| Furnace Return Make-up Air Questions | 6/25/2009 |
Q: I am installing a 40K btu 92% nat gas furnace (horizontal mount). I have a concentric vent/supply ... A: Jason, Make up air is fresh air brought in because homes are built so tight now that we breath all ...
|
| Trane AC | 6/25/2009 |
Q: I have a trane 4ton unit that was made in 2000. Sat I started action up and the compressor wasn't ... A: Jim, I am sorry I really cannot understand what you are asking? I know of nothing that is a prv?? ...
|
| Rheem | 6/24/2009 |
Q: I am looking at a 3 ton rheem its about 12 years old.It will not take any freon my suction is at 45 ... A: Joe, At 45 psig it should take refrigerant, because your jug should be about 100 psig. You might ...
|
| AC tripping circuit breaker | 6/24/2009 |
Q: My older AC compressor unit is drawing too much power on start up and tripping the breaker. ... A: Sue, It really shouldn't be able to start a fire, but it can be damaged and need to be replaced, ...
|
| A/C return vents | 6/24/2009 |
Q: I am replacing my old return vent with a larger one. This is the only one in the home that i know ... A: Matthew, Yes to a.) and the return size of the vent is only critical that it is not fewer square ...
|
| Hot second floor. Need an air return? | 6/24/2009 |
Q: I have a 100 year old 2 story home. The main floor is adequately cooled, but the second floor is ... A: Steve, One of the things you should consider, regardless of every thing else is a thermostat ...
|
| Stop Smoke in Dual Zone System | 6/24/2009 |
Q: I have a duplex rental with one HVAC system. Each unit has a thermostat and a return. One tenant ... A: Eric, You can install an activated charcoal filter to control odors. The problem with them is ...
|
| Keeprite central air | 6/24/2009 |
Q: We are new to owning a house and have never had central air before. So I was wondering how to turn ... A: Crystal. No, Crystal it runs off electricity. The thermostat has a system switch that has a cool ...
|
| Residential Air Conditioning/Furnace | 6/24/2009 |
Q: After I put on the AC it only runs for about a minute and then shuts off, without bringing the ... A: Tim, turn the "Fan" switch on the thermostat to the ON position by itself and see if the blower ...
|
| plastic drain pan leak | 6/24/2009 |
Q: we had an A/C company out last week to clear a clogged line. he cleared the line but then told us ... A: Mark, If the tech sealed up the crack there is no reason to replace it. Does the aux. pan have a ...
|
| Air conditioner | 6/24/2009 |
Q: My air conditioner will not cool below 75 degrees during the hottest part of the day. Please advise ... A: Nodea, I already answered this question, why didn't you check the insulated copper pipe where it ...
|
| Residential A/C Dye Test | 6/24/2009 |
Q: John - our A/C Company said we are leaking freon and just did a dye test for almost $100. I ... A: Brian, You are asking the wrong person because.....it will get me on my soap box. As a ...
|
| Air conditioner | 6/24/2009 |
Q: My air conditioner will not cool below 75 degrees during the hottest part of the day. Please advise ... A: Nodea, The way to tell if your A/C is close to being set up correctly is as follows. First make ...
|
| Gibson heat pump not cooling | 6/23/2009 |
Q: I have two Gibson units for my home, one for upstairs and one down. Both installed in 2003. The ... A: Steve, The click you heard was the contactor pulling in, which is good it is supposed to on a call ...
|
| Gibson heat pump not cooling | 6/23/2009 |
Q: I have two Gibson units for my home, one for upstairs and one down. Both installed in 2003. The ... A: Stave, Yes another tech that knows his job. at the outdoor unit, there is a large copper pipe ...
|
| cooling temperature control | 6/23/2009 |
Q: cndMy wife sets the t-stat about 5 degrees higher when we leave in the morning (and we argue about ... A: Bill, I don't like to get in marital disputes....lol An A/C by design is ment to hold temperature ...
|
| Blower always running | 6/23/2009 |
Q: Alright last winter the heat on my unit wuit working, the blower and the inducing fan always are ... A: Christina, John Borgman here, I got this question from our question pool. Could you provide me ...
|
| HVAC system | 6/23/2009 |
Q: We installed a new frigidaire hvac unit in 2004. We have had nothing but trouble w/ the temperature ... A: If the outdoor unit is not running and the indoor is, check the tstat. Is the fan switch set to the ...
|
| TXV valve | 6/23/2009 |
Q: My downstairs air conditioning stopped cooling a week ago. It is a Bryant 5 ton system that is only ... A: Steve, I don't have a cross reference guide to tell if the replacement was correct, but it ...
|
| AC Unit | 6/23/2009 |
Q: I went outside to check Ac the fan wasn't runining and it was real hot on back of fan motor. The ... A: Charles, Hi John Borgman here got this from our question pool. With the power off to the outdoor ...
|
| HVAC system | 6/23/2009 |
Q: We installed a new frigidaire hvac unit in 2004. We have had nothing but trouble w/ the temperature ... A: Jennifer, Wow, what a horror story......You have a freon leak, but it is not at the indoor coil ...
|
| Outdoor A/C no longer functioning with new furnace. | 6/23/2009 |
Q: We recently had our old (Olson Duomatic) mid-efficiency furnace replaced with a Trane Xv95 (model ... A: Renay, Just curious where in Europe are you? Anyway the thermostat will send a signal through the ...
|
| home ac unit | 6/23/2009 |
Q: i have a heating and cooling guy out here now.had ac installed two years ago and the system looses ... A: Mike, If he took it to 400 psi and it held there is no leak, at least not one that could happen ...
|
| poor airflow in finished attic | 6/23/2009 |
Q: I have a small home built in the 1940s that has been expanded twice. The original house is about ... A: Dave, The inline blower would create as much resistance as it produces. My biggest question is why ...
|
| Air handler and compressor not turning on | 6/23/2009 |
Q: I have a spacepack a/c system and a hot water boiler as my HVAC system in my house. I replaced the ... A: Benjamin, When a thermostat has an Rc it also has an Rh. Those two need to be jumped for heat and ...
|
| York Diamond 80 - 9 Flashes | 6/23/2009 |
Q: I have a York Diamond 80 heating and central air conditioning unit. When I turn it on, it flashes 9 ... A: Donald, John Borgman here got this from our question pool. It means that something has gone to ...
|
| Bryant vs Payne 3 ton 13 SEER heat pump/ac unit | 6/22/2009 |
Q: Our Bryant 3 ton 13 SEER heat pump/ac unit went out and we had to fight with FirstAM Home Warranty ... A: Linda, Payne, Bryant and Day and Night are all Carrier, they give different names and different ...
|
| price of central air | 6/22/2009 |
Q: i have a 1976 model 14x70 trailer house. it has cental heat but not air. a family member of mine ... A: Joseph, No, only one per breaker, those are run load amps. When the window unit starts it pulls ...
|
| Which air units to buy | 6/22/2009 |
Q: John, Help, our air conditioning went out this weekend and we have had 3 people trying to sell 3 ... A: Kim, The Trane would be the $5,700 it is always the most of those three, Payne is the middle of ...
|
| Hard Start Kit for small A/C system | 6/22/2009 |
Q: I have a small ductless mini split system (Heat Controller, Inc.) that conditions a room over a ... A: Ron, Cost of call was reasonable, as far as the rest, no way to tell without, being there and ...
|
| ac window unit cycles compressor on off | 6/22/2009 |
Q: we have a small ac window unit that has begun to cycle the compressor on and off every 5 minutes or ... A: Keith, The problem with window units is that since you can get a brand new one at home depot for ...
|
| Intertherm A/C Leaking | 6/22/2009 |
Q: We have an Intertherm A/C and heat pump in a double wide mobile home. The inside unit is leaking ... A: Claudette, A couple of questions for.....All vents open and not covered? Is your filter clean? ...
|
| residential a/c | 6/22/2009 |
Q: what should the proper pressures be (high and low side) on a 410A system thanks ANSWER: Woody, ... A: Woody, In looking over your numbers briefly, I need to know if in fact the supplies and the ...
|
| Air Conditioning: Keep basement door shut? | 6/22/2009 |
Q: We have a carrier system that is about 7 years old installed to cool main floor and walkout ... A: Connie, No, shutting down vents is never a good idea as far as efficiency and longevity of your ...
|
| added misters to AC | 6/21/2009 |
Q: I ran a 3/8" water line up to my roof mounted AC/Heat pump and installed misters above the intake ... A: Allan, I wouldn't recommend the mister due to the affect it has on the head pressure of your ...
|
| expansion valves | 6/21/2009 |
Q: what are the steps to change them out A: Robert, All refrigerant must be recovered or pumped to the other side of the service valve from ...
|
| air conditioning | 6/21/2009 |
Q: How to reduce the static pressure like form 0.35wc to 0.25wc,and is that mean I have problem with my ... A: Sam, The static pressure would increase with fan speed, the filter could be dirty, the duct system ...
|
| Attic heat re-circulation... | 6/21/2009 |
Q: ..my attic is obscenly hot while my house is too cool. I'd like a solar-powered (12v) duct inline ... A: David, Answer is the same and I have had a couple of people that I spent good amount of time re ...
|
| Adding R-410A | 6/21/2009 |
Q: I used to charge my home AC system when R-22 was common. I've added R-22 in both liquid and gas ... A: Don, That is a HUGE leak and your service company are very incompetent . I could find that leak ...
|
| ruud central a.c. | 6/21/2009 |
Q: I have a ruud central a.c. older model maybe 30 years old. About a week ago it started noticing that ... A: Ed, you will take a huge chance on damage if you continue to use the A/C. Could possibly take out ...
|
| ruud central a.c. | 6/21/2009 |
Q: I have a ruud central a.c. older model maybe 30 years old. About a week ago it started noticing that ... A: Ed, It is physically impossible for the refrigerant to flow into the condenser when the compressor ...
|
| Adding R-410A | 6/21/2009 |
Q: I used to charge my home AC system when R-22 was common. I've added R-22 in both liquid and gas ... A: Don, The reason for not trying to add 410a on the high side is that, the standing pressure in your ...
|
| residential a/c | 6/20/2009 |
Q: what should the proper pressures be (high and low side) on a 410A system thanks ANSWER: Woody, ... A: Woody, Are you sure that you are on a 410a system? Something is terribly wrong if you are. The ...
|
| Time to Replace All | 6/20/2009 |
Q: House is 25 years old and I suspect unit in attic is that old. Coleman blend air system upstairs and ... A: Francis, John Borgman here, got this out of our question pool. If you replaced the duct system ...
|
| white-rodgers digital thermostat | 6/20/2009 |
Q: the thermostat often shows the temperature as getting warmer as the air conditioner is running. It ... A: Karen, Yes the pipe will drip there more than other area's due to the high humidity. If it is ...
|
| Solder or braze AC outdoor unit repair | 6/20/2009 |
Q: York central air outdoor unit approx. 2 years old. AC stopped cooling. Repair tech found no R-22 in ... A: Ken, Actually I appreciate the long response, gives me a lot more to go on. oxy/acetylene is the ...
|
| Corroded Coils? | 6/20/2009 |
Q: I have a Day and Night residential 3 ton unit and the unit is ground-mounted on a cement slab next ... A: Jim, Yes urine can do that....bad dog. But just because the techs electronic detector sounded, ...
|
| Attic heat re-circulation... | 6/20/2009 |
Q: ..my attic is obscenly hot while my house is too cool. I'd like a solar-powered (12v) duct inline ... A: David, It doesn't work that way, David. Even if you have no insulation under your home, that ...
|
| ac unit won't cool | 6/20/2009 |
Q: I have turned on my unit, which is 8 years old, and it runs but doesn't cool at all. I assume it ... A: Ken, I will assume you mean that just the A/C is outside and that you have and indoor furnace/air ...
|
| Insulation on Return Air Ductwork | 6/20/2009 |
Q: Mr. Borgman, I live in northwest Florida. The humidity and heat here are often very high. My home ... A: Shawn, Call your local utility company and ask that question. The reason for this, is, they might ...
|
| white-rodgers digital thermostat | 6/20/2009 |
Q: the thermostat often shows the temperature as getting warmer as the air conditioner is running. It ... A: Karen, First you shouldn't have any type of devise pulling hot air from the attic. Are you saying ...
|
| Frigedaire central air conditioner | 6/20/2009 |
Q: what causes the inside panel to fry, and how hard is it to replace? my air conditioner didn't work, ... A: Karen, Got this question from our question pool. A lot of things can cause the " board " to burn ...
|
| central AC noise inside unit | 6/20/2009 |
Q: While running it sounds like a fan is rubbing under the inside coil. Unit is 2 years old A: Jim, The set screw that holds the blower wheel onto the shaft of the blower motor sometimes is not ...
|
| Solder or braze AC outdoor unit repair | 6/20/2009 |
Q: York central air outdoor unit approx. 2 years old. AC stopped cooling. Repair tech found no R-22 in ... A: No, you are not nuts and unfortunately you have not had a pro out anyway. Jeez , 2 years ...
|
| residential a/c | 6/20/2009 |
Q: what should the proper pressures be (high and low side) on a 410A system thanks ANSWER: Woody, ... A: Woody, The 240/60 measurement would only work under the exact condition of outdoor ambient ...
|
| New Unit Not Cooling | 6/20/2009 |
Q: We had a Goodman 2.5 ton split heat pump system put in this morning. The temperature has not ... A: Karen, that is the biggest line of bull I have ever heard. I assume you are trying to cool? At the ...
|
| air handler - coil leak | 6/20/2009 |
Q: I live in rural Maryland outside of Washington D.C. I have owned my home since it was built in 1997. ... A: Raye, If it worked when they left a week ago, would be kinda hard for them to have left something ...
|
| Wiring AC to furnace circuit board | 6/19/2009 |
Q: My father-in-law replaced my furnace this winter with a new ArcoAire 80+ single stage furnace. All ... A: Curtis, One wire goes to the "C" terminal, it is the low voltage common. The other Goes to the ...
|
| residential a/c | 6/19/2009 |
Q: what should the proper pressures be (high and low side) on a 410A system thanks A: Woody, I would be happy to help you understand what and why the pressures and the temperatures ...
|
| Water dripping from Air conditioner | 6/19/2009 |
Q: Recently turn on Air conditioner in basement. Water are dropping from A/C. Can you advise how I can ... A: Howard, You have one of two problems. A physical leak from the part of the system that catches ...
|
| a/c is blowing air but not cooling | 6/19/2009 |
Q: My central a/c in my house stopped cooling last night. The unit outside is running and the lines did ... A: Hannah, The noise in the attic could be a condensate pump that removes the water made from the ...
|
| fuses blowing on ac unit | 6/19/2009 |
Q: I bought a 4 ton 13 Seer SPP G/E in Nov/2007. have had no problems until this past Sunday. It just ... A: Mary, No do not change it to a breaker. A breaker does not give enough protection for the ...
|
| AC/Heat Pump compressor runs sporadically | 6/19/2009 |
Q: Our central AC/Heat Pump occasionally won't run. I checked pressure (85 low, 185 high) when it does ... A: Rick, Not beginners mistake, but , learning experience. There are 2 types of start relays when ...
|
| American Standard Freedom 80 making a high whine noise. | 6/19/2009 |
Q: First thank-you very much for your time. I have an American Freedom 80 model number AUD80C936J1, It ... A: Karen, Hi, John Borgman here got this question from the question pool. IFC is integrated fan ...
|
| Armstrong Heat Pump Problem | 6/19/2009 |
Q: I have an Armstrong heat pump (Concept 10)that decided that it doesn't want to turn on this summer. ... A: Paul, First you should measure across the contactor load end just as a matter of good ...
|
| Compressor info | 6/18/2009 |
Q: This is the info I got from one company yesterday. My compressor started for only couple sec before ... A: Teri, time to get on the phone and get another company to come out. I really cannot help you ...
|
| fuses blowing on ac unit | 6/18/2009 |
Q: I bought a 4 ton 13 Seer SPP G/E in Nov/2007. have had no problems until this past Sunday. It just ... A: Mary, first call someone else, it is a very simple matter for a tech to find out why the fuse blew ...
|
| AC/Heat Pump compressor runs sporadically | 6/18/2009 |
Q: Our central AC/Heat Pump occasionally won't run. I checked pressure (85 low, 185 high) when it does ... A: RICK, Could be a lot of causes that all point to abnormal running conditions and would need to be ...
|
| air handler - coil leak | 6/18/2009 |
Q: I live in rural Maryland outside of Washington D.C. I have owned my home since it was built in 1997. ... A: Raye, No there are wrong and to go so far with the explanation and quoting laws that do not exist, ...
|
| air conditioning | 6/18/2009 |
Q: My outside unit is running all the time- whether inside is blowing cold air or not. I had to ... A: Heidi, Lets make sure we are not talking "apple and oranges" The furnace is the indoor section ...
|
| Follow up to Ruud Heat Pump | 6/18/2009 |
Q: Our inside unit is located in the basement behind shutter doors. Last night I noticed the floor in ... A: I donate hours of my own time daily/weekly to help those that appriciate it and go out of there way ...
|
| Compressor info | 6/18/2009 |
Q: This is the info I got from one company yesterday. My compressor started for only couple sec before ... A: Terri, I agree about the 3 weeks thing, if you were my customer I am sure I could get my supplier ...
|
| AC/Heat Pump compressor runs sporadically | 6/18/2009 |
Q: Our central AC/Heat Pump occasionally won't run. I checked pressure (85 low, 185 high) when it does ... A: Rick, what made you hit the compressor housing to fix it? I would need a lot more info to give you ...
|
| ac not turning off | 6/18/2009 |
Q: we have an older central air unit/furnace and we turned it on a few days ago and it won't stay ... A: Krissa, Sounds like one of two things. One the thermostat is not working correctly and if so must ...
|
| Heat Pump | 6/17/2009 |
Q: My daughter has a Lennox heat pump. We live in Central Florida and the unit is three years old. ... A: Dottie, If the tech installed the motor, why must he wait till tomorrow to see if it fixed the ...
|
| Vibrating Vents | 6/17/2009 |
Q: We bought a new house last November, we ran the central heat through the winter with no problems. ... A: Bill, It sounds like you are getting a harmonic transfer from the compressor in the outdoor unit, ...
|
| Ruud Heat Pump | 6/17/2009 |
Q: We have a 1998 Ruud AC/HP UPNJ-025JAZ. We had a service person out because air was blowing through ... A: Janice, the national average is 17 years. To just repair a freon leak in the indoor coil that seems ...
|
| Magic Chef HVAC water problem | 6/17/2009 |
Q: I have a Magic Chef HVAC unit in a hall "closet" that is dripping water by the gallons. It has not ... A: James, where does the drain go? can you run water through it out of the home without it backing up ...
|
| Residental air conditioning and heat pump | 6/17/2009 |
Q: I have two questions please: 1- in heat pump what will happen to the system if I reversed the ... A: Sam, First question, The accumulator will not be able to do its job correctly. And the HP will not ...
|
| AC not cooling | 6/17/2009 |
Q: My AC was on for 4yrs and never got cool in my house. Had a man come look at it and was told the ... A: Terri, Here is a list of questions you need answered at the service call tonight. I would ask these ...
|
| AC Coil leak in attic | 6/17/2009 |
Q: I had an AC tech out to look at the air handler? portion of my AC unit located in our attic. It has ... A: Holly, The main drain pan is not the coil, it is what the coil sits on to catch the water that runs ...
|
| air condensor leak | 6/17/2009 |
Q: There has been a leak in my bathroom for a week now. I contacted the property manager/maintenance ... A: Tara, First of all the condenser is the outdoor unit, not the one inside. You are correct that the ...
|
| A/C is leaking | 6/17/2009 |
Q: I have a central A/C unit. The blower+coils are in the attic. For about a week now I have been ... A: Joe, For that fix you are going to need a service tech to figure it out on site or run a new one if ...
|
| A/C - house doesn't get cool | 6/17/2009 |
Q: I just had the motor for the blower replaced on my ac system. The ac blows cool air (65 degrees) ... A: Craig, Before we look at the numbers, the thing about the blower being installed upside down is ...
|
| AC not cooling | 6/16/2009 |
Q: My AC was on for 4yrs and never got cool in my house. Had a man come look at it and was told the ... A: Terri, yes that is a completely different set of circumstance as far as the wiring. The box on the ...
|
| manifold pressure | 6/16/2009 |
Q: i forgot to yell you that is r22 for my questin. thanks john for your help A: Yes I knew you were talking R22. Keep this is mind The purpose of the outdoor coil ( condenser ) ...
|
| MANIFOLD PRESSURE | 6/16/2009 |
Q: WHAT PRESSURE SHOULD THE HIGH AND LOW BE ON THE MANIFOLD GAUGES? IF THE LOW IS HIGH I KNOW YOU ADD ... A: Paul, you do not add R22 to bring the low side pressure down, that will increase it. You add R22 to ...
|
| Icing up | 6/16/2009 |
Q: We have an Intertherm split unit I guess you would call it for a mobile home. It's a heating and ... A: Paul, remove the filter and see if it runs normal, that is the quick answer. Mobile homes have poor ...
|
| Coil replacement | 6/16/2009 |
Q: We had our evaporator coil replaced about 1.5 years ago. Our air conditioner was not cooling ... A: Lisa, Why in the world would you have the secondary drain pan replaced. It is just a metal pan ...
|
| York Central Air Unit | 6/16/2009 |
Q: I have a York Central Air Unit, 3 zones and 2 programmable thermostats. When you first turn the ... A: Lisa, As I said, you will need a tech on site that understands zone systems. If you in fact had the ...
|
| AC not cooling | 6/16/2009 |
Q: My AC was on for 4yrs and never got cool in my house. Had a man come look at it and was told the ... A: Terri, I recommend you call another company, one that has N.A.T.E. certified techs. If everything ...
|
| air conditioning/ heatpump | 6/16/2009 |
Q: Air conditioning on heat pump runs all day during the day. I can turn the temp up and 10 minutes ... A: Debbie, I understand what you are describing. And I am sorry to ask another question of you, but if ...
|
| Trane Air Handler Dripping/Freezing up | 6/15/2009 |
Q: Help. I have been told valve (mercury) has gone bad and that is why the unit is developing ice. Ice ... A: Derek, If your filters are clean and all the vents are open and it is doing this, you have a freon ...
|
| AC temp variances | 6/15/2009 |
Q: What should the difference from outside to inside actually be? EX: 95 outside, will the ac take a ... A: Donna, if the duct system and the equipment are sized correctly and set up and running correctly, ...
|
| Power spikes when air condition comes on | 6/15/2009 |
Q: I just recently had a Lennox 5 ton XC14-060 air condition installed. Each time the unit starts, ... A: Jennifer, Did an electrician do the high voltage part and run a branch circuit? Your right about ...
|
| house not cooling | 6/15/2009 |
Q: i recently replaced a old York unit with a new Goodman unit. i have power working at the unit, when ... A: Carlos, The large line with the black insulation should be cold and dripping wet where it connects ...
|
| replacing filter | 6/15/2009 |
Q: cant find where to put the new filter (cant find the old one). i really need help tempster dc90 ... A: Penny, I get the impression that this has not been done in a long time. A year? two? If so, make ...
|
| York Central Air Unit | 6/15/2009 |
Q: I have a York Central Air Unit, 3 zones and 2 programmable thermostats. When you first turn the ... A: Lisa, With zone control systems you need a good tech on site, too many things to do on line to find ...
|
| A/C | 6/15/2009 |
Q: We have an new central A/c that was installed on our existing furnace. But we don't believe it is ... A: Bon, Now that the fan is on high, which is where it should be, you should have your freon checked. ...
|
| please help | 6/14/2009 |
Q: Good Day, One Day Air was working fine (could cool to whatever we put the temp on. We kept it ... A: The amp draw on your motor is normal. As far as pressures and " sweat back and good condensation" I ...
|
| Air Handling Pannel | 6/14/2009 |
Q: My York unit #G/HCO36AA has a rusted out condensate pan. The unit is in three section stacked on top ... A: There are screws on some coils on the back side opposite of the pvc connection. They all have some ...
|
| Unit will not run | 6/14/2009 |
Q: I have a Goodman 070-3. My A/C unit will run for about 5 minutes before turning off which is about ... A: Your outside unit is your A/C, the indoor unit is called the Air Handler, which is where the blower ...
|
| Heat Pump | 6/14/2009 |
Q: My daughter has a Lennox heat pump. We live in Central Florida and the unit is three years old. ... A: Wow..........I would hope they are not charging you for all this. For the high pressure switch to ...
|
| a/c drain | 6/14/2009 |
Q: My air handler is in the attic,during the summer it drains 4 a lil while like it should then the ... A: Good choice of what to look at. The only way to have water in that pan is for the dain to be ...
|
| trouble shooting | 6/14/2009 |
Q: John: I have recently obtained my hvac certificate from Cape Fear com. col. in Wilmington NC. I was ... A: David, you answered your own question. You CANNOT ommit the evacuation process. The reason your ...
|
| new HP compressor not pumping | 6/14/2009 |
Q: I installed a Ducane 2 ton HP two years ago and had to replace compressor last year due to bad ... A: Mark, When you are at this unit and calling for heat or cool from the tstat and your gauge's are ...
|
| Zoned A/C retrofit | 6/13/2009 |
Q: John, Would you please let me know what is involved with changing from two separate AC systems to a ... A: Will be way cheaper to fix them. All the duct work will have to be redone. Mechanical zone dampers ...
|
| AC freezing cooling downstairs not upstairs | 6/13/2009 |
Q: We have a Lenox AC/Heating Unit. I has been working fine, but recently it is freezing up. The AC ... A: A.Yon, If you have icing then your system is not working correctly. It will not freeze if it is set ...
|
| trouble shooting | 6/13/2009 |
Q: John: I have recently obtained my hvac certificate from Cape Fear com. col. in Wilmington NC. I was ... A: David, give me high and low pressure, suction line temp and liquid line temp at outdoor unit. ...
|
| A/C - house doesn't get cool | 6/13/2009 |
Q: I just had the motor for the blower replaced on my ac system. The ac blows cool air (65 degrees) ... A: The blower is the indoor unit. which motor was replaced? The outdoor unit, "pulls" air across the ...
|
| Lennox Model CB28UH-030-01 | 6/13/2009 |
Q: 1. Should I be able to get the Model and Serial Number off the front of the unit? 2. Is this really ... A: Model and serial are on the outdoor unit , yes. If you want to know if it is a heat pump, you need ...
|
| Follow up | 6/13/2009 |
Q: John: sorry for another question. I am still stumped by my blower motor. This morning I went out ... A: Rick, if the unit cools fine in the cooling mode with the fan switch in the on position? Is that ...
|
| AC compressor noise | 6/12/2009 |
Q: I have a 5 ton central air AC unit (just AC, no heat). It seems to operate normally (it cools the ... A: I am sorry, that is one of the few units I am not familiar with coded serial numbers to find date of ...
|
| HVAC Thermostat | 6/12/2009 |
Q: We installed a new Carrier Performance Series 15.5 seer. Contractor installed a "Non-programmable" ... A: Debora, No there are no requirements like that and if there were it wouldn't make a difference. ...
|
| Fan Relay Switch Replacement | 6/12/2009 |
Q: I have a Bard split unit heat pump. Have been quoted a price of $220, part only, to replace this ... A: Dan, not many Bards around here. Is this an electric furnace/ air handler? If they use a simple ...
|
| Refrigerant lines | 6/12/2009 |
Q: We're replacing our 20+ year old Janitrol system. One contractor has said that we have to replace ... A: Replace the lines. If you would like the physical reasoning read on....410a has a completely ...
|
| Blower Transformer/Continuation/More Details | 6/12/2009 |
Q: If a newly installed blower transformer is incorrectly wired, will it blow out the newly installed ... A: You need to contact the owner of that company. Do NOT have him back out, he doesn't have a clue as ...
|
| AC compressor noise | 6/12/2009 |
Q: I have a 5 ton central air AC unit (just AC, no heat). It seems to operate normally (it cools the ... A: Emmanuel, It sounds to me like the refrigerant equalizing, ie, when running there is a difference ...
|
| A/C - house doesn't get cool | 6/12/2009 |
Q: I just had the motor for the blower replaced on my ac system. The ac blows cool air (65 degrees) ... A: Craig, Did it work fine before the blower? Could be on the wrong speed. When it has been running ...
|
| Blower Transformer | 6/12/2009 |
Q: If a newly installed blower transformer is incorrectly wired, will it blow out the newly installed ... A: No, but a newly installed blower wired wrong will burn itself up. The wire on the other hand is ...
|
| A/C | 6/12/2009 |
Q: This particular system is a split--heat pump R-22.This unit has a sight glass on the liquid ... A: My name is John, I found your question in our pool of unanswered questions. The actual temperature ...
|
| Blower motor -- intermittent problem | 6/12/2009 |
Q: I have a Heil package heat pump. The blower motor is failing to start about half the time when I ... A: Rick. Kinda cool , you are learning a lot about your equipment. With this new info it is sounding ...
|
| Breaker Size | 6/12/2009 |
Q: Borgman, Thanks for accepting my question. I have an Old 240V GE Electric Furnace (1973 year)with a ... A: Although some of the current is stepped down for low voltage control, it amounts to very little ...
|
| window unit | 6/12/2009 |
Q: I then heard it come on but diddnt stay on but for few seconds.unit is only 3 years old and is on ... A: The only way to know about the unit and the breaker is by the amp draw total of the window unit. If ...
|
| Blank Thermostat | 6/11/2009 |
Q: I have an intermittent problem that began 6 months ago. Was happening once a month. Now once a ... A: Ok, if it a package unit on the roof and it also happens in heating, then it is not that. If he ...
|
| RTH221B Honeywell thermost wiring? | 6/11/2009 |
Q: Well,here is my question.I had a old round thermoststat and replaced it with the honeywell rth22b in ... A: You are welcome. It sounds like it might be more than you are ready to handle and you might need a ...
|
| Rheem vs Lennox A/C unit? | 6/11/2009 |
Q: I have single story approx. 1340 sq ft home that I am putting A/C on. I have 2 quotes one is for a ... A: Bobby, all companies offer cased or uncased coils, just depends on the bidder. If there is ever a ...
|
| Compressor comparison, cont. from 6-10 | 6/11/2009 |
Q: I thought I would go ahead and just turn the system on and describe the conditions. Outside ambient ... A: It should be the large insulated line that is wet. And you should have about a 20 degree difference ...
|
| Split AC Not Cooling | 6/11/2009 |
Q: I have a 1 ton videocon split air conditioner at my home. Most of the time it does not cool i.e. the ... A: You can get a ball park idea, if, your equipment is set up correctly, by, when it has been running a ...
|
| Compressor comparison | 6/11/2009 |
Q: I need to replace my compressor on a Trane unit. Due to finances, I need to spend minimal dollars. I ... A: You are describing the service valve, which if leaking can be repaired or replaced. Again it is ...
|
| Compressor comparison | 6/11/2009 |
Q: I need to replace my compressor on a Trane unit. Due to finances, I need to spend minimal dollars. I ... A: Slow down.....If the large line was freezing then the compressor is working. Do you remember the ...
|
| Compressor comparison | 6/11/2009 |
Q: I need to replace my compressor on a Trane unit. Due to finances, I need to spend minimal dollars. I ... A: One is a 48,000 btu capacity and the other 51,000. You really need to match it with the correct ...
|
| Heat Pump | 6/11/2009 |
Q: I have a Miller heat pump. I turned on my air and although it is blowing it is not very cold. The ... A: It would be in that box. I don't know the codes there but I am surprised it is not code. If there ...
|
| Secondary drain pan | 6/11/2009 |
Q: Greetings, I just had my evaporator coil replaced by a local company sent by the home warranty ... A: Wow all kind of red flags. First since the auxiliary drain pan is under the evaporator, why did ...
|
| Heat Pump | 6/11/2009 |
Q: I have a Miller heat pump. I turned on my air and although it is blowing it is not very cold. The ... A: I don't believe " Miller" brand has a manual reset for high pressure. The disconnect box on the ...
|
| Mobile Home A/C Air Flow | 6/10/2009 |
Q: I have a modular home (essentially a double wide)about 2,000 sq. ft. with a heat pump. The rear half ... A: "bow" was a typo....sorry. If you pull a register and look under it you will see the size of the ...
|
| HVAC cycling on/off | 6/10/2009 |
Q: Just moved into a new home. Unit is a Lenox 5 ton. Problem is that the unit cycles on until unit ... A: The t-stat should be as close to the return air as possible. Most t-stats have an adjustment that ...
|
| Blank Thermostat | 6/10/2009 |
Q: I have an intermittent problem that began 6 months ago. Was happening once a month. Now once a ... A: I need a little more info on what kind of a t-stat, but generally it could be a faulty t-stat or if ...
|
| Leaking Air Conditioner | 6/10/2009 |
Q: I have a brand new 09 5 ton, 14 seer RUUD unit just installed 2 months ago. When the unit shuts ... A: That is what I was trying to explain in my prior.....The coil drain pan has a pvc connection coming ...
|
| Air Handle / Duct work | 6/10/2009 |
Q: My condensing unit is toasted and we are replacing it. It is a 3 ton. Furnace is in good shape. The ... A: A 7' duct can handle 150 to 175 cfm and an 8" can handle 200 cfm at .1 static. I suppose if those ...
|
| Blower motor -- intermittent problem | 6/10/2009 |
Q: I have a Heil package heat pump. The blower motor is failing to start about half the time when I ... A: Generally there is a control module, ( board ) that controls that, but it could be one or the ...
|
| poor air flow to second floor | 6/10/2009 |
Q: ..my family and I moved into a 2-story contemporary home last August. The main floor is open to ... A: Unfortunately, this is a typical problem with 2 story homes. When built , they really don't put ...
|
| RTH221B Honeywell thermost wiring? | 6/9/2009 |
Q: Well,here is my question.I had a old round thermoststat and replaced it with the honeywell rth22b in ... A: You need a jumper from Rh to Rc ( rh=heat rc=cooling) green is correct. You should have a y and w ...
|
| Mobile Home A/C Air Flow | 6/9/2009 |
Q: I have a modular home (essentially a double wide)about 2,000 sq. ft. with a heat pump. The rear half ... A: No, unfortunately , each side has a single bow duct the same size that runs the full length and the ...
|
| Blower motor -- intermittent problem | 6/9/2009 |
Q: I have a Heil package heat pump. The blower motor is failing to start about half the time when I ... A: The contactor has a rating tag on it that gives you coil voltage. It should be 24 volts unless you ...
|
| Condensor fan replacement | 6/9/2009 |
Q: The fan on my daughters outside condensing unit is making a lot of noise and needs replacing. I am ... A: Paul, the condenser fan motor is a 1075 rpm single speed PSC. That means permanent split capacitor ...
|
| upgrading to programmable t-stat | 6/9/2009 |
Q: My heat pump (no ac) is model U80-2. I got a Lux TX1500 digital t-stat to upgrade my old ... A: If you had just gas & A/C I wouldn't object, but since you have a heat pump, I would not put that ...
|
| Leaking Air Conditioner | 6/9/2009 |
Q: I have a brand new 09 5 ton, 14 seer RUUD unit just installed 2 months ago. When the unit shuts ... A: With the door off you change every thing, so you cannot go by that. If it is leaking at the furnace ...
|
| Air Handle / Duct work | 6/9/2009 |
Q: My condensing unit is toasted and we are replacing it. It is a 3 ton. Furnace is in good shape. The ... A: Eric, If you haven't cut holes yet, you might consider making what you have better, by not having an ...
|
| baseboard heat aluminum fin alignment | 6/9/2009 |
Q: Does it matter which way the fins are turned on the baseboard unit? I believe the aluminum "fins" ... A: Ron, The baseboard heater transfers heat to the room by convection. That is, it is the molecules of ...
|
| Air conditioner unit | 6/8/2009 |
Q: Bryant 567dj030- First the contactor was stuck closed, but the unit was not operating. Power was ... A: The contactor is supposed to be closed when there is a call for cooling, so if you were trying to ...
|
| Replace Unit Options | 6/8/2009 |
Q: I have a older "gas pac" that needs replacing. Is a "gas pac" still a good option, or is the newer ... A: Because of where you live, you should stay away from the heat pump. It will spend all its time ...
|
| Strange vibrating noises from my attic | 6/8/2009 |
Q: For the last few months I've been occasionally hearing loud vibrating noises coming from the attic ... A: Gina, I really don't know, could be the blower motor coming on or off (bearings getting worn ) ...
|
| New Heat Pump AC run time | 6/7/2009 |
Q: I have a new tempstar heatpump and have had the installing company back 6 times for service. I am ... A: First let me apologize for the installing company. The chance of a new t=stat being bad these days ...
|
| Air conditioning system conked out | 6/7/2009 |
Q: My home air conditioning system started acting funny recently and then finally conked out. There is ... A: I can tell you right now you are going to need a service call. But, you have some interesting ...
|
| no power? | 6/6/2009 |
Q: I recently switched out my breaker box to accomodate my electric water heater and when I got it all ... A: Tested wiring at the unit??? Does this mean you have 110 volts at the unit? A couple of things come ...
|
| goodman heat pump transformerproblem | 6/6/2009 |
Q: transformer keeps blowing low voltage gets very hot checked wiring for shorts seems to happen when ... A: Do you mean that a fuse keeps blowing in the furnace? a 3 or 5 amp plug in fuse? Not knowing how ...
|
| House with 2 HVAC systems | 6/6/2009 |
Q: I recently purchased a home with two HVAC system. The upstairs unit is a heat pump with electric ... A: It would take someone with above average knowledge to set both units up off one controller as the ...
|
| water in my airhandler | 6/6/2009 |
Q: Recently my evaporator coil iced and the metal box below it (which I believe collects the returning ... A: There is part of your problem, the folded air filter. Air takes the least path of resistance, so ...
|
| suction line 130 psi ? | 6/6/2009 |
Q: what might be the reason for such high pressure for low line ? i have lennox split ducting unit , ... A: I assume an r-22 unit? If so and not a heat pump, you have a mechanical failure of the compressor. ...
|
| water in my airhandler | 6/6/2009 |
Q: Recently my evaporator coil iced and the metal box below it (which I believe collects the returning ... A: It is more than likely insulation. Now since you can see it, you are looking under the blower motor ...
|
| air conditioner capacitor | 6/5/2009 |
Q: i am looking to replace the dual capacitor in our central air conditioner at home, it has a ... A: Did you pull the cap from its mount and look? If so, and you cannot read it, you will need to ...
|
| water coming out of indoor HVAC | 6/5/2009 |
Q: We just had a new HVAC-heat pump installed (indoor & outdoor unit) and water seems to be backing up ... A: OK. Then if this is a new install it should be reported to the company you bought it from, so they ...
|
| water coming out of indoor HVAC | 6/5/2009 |
Q: We just had a new HVAC-heat pump installed (indoor & outdoor unit) and water seems to be backing up ... A: I might need a little more info....But in the mean time.... Water does not flow up hill, make sure ...
|
| American Standard Freedom 90 blower problem | 6/5/2009 |
Q: I have an American Standard Freedom 90 furnace with a brand new (yesterday) American Standard ... A: When you pull the door or kill the power by the safety switch, the board re-sets itself, erasing any ...
|
| central air copper size | 6/5/2009 |
Q: I have an old ac unit (I think the original lol) about 30 years old. I had two companies say I need ... A: Doug, Now that is a different story. You MUST replace the line set, no if's or but's. Oils from ...
|
| charging procedure | 6/5/2009 |
Q: I have a central air condensing unit I have to replace is there some other way I should be charging ... A: If you are replacing it, the proper way to charge is by weighing the new charge, adding or ...
|
| central air copper size | 6/4/2009 |
Q: I have an old ac unit (I think the original lol) about 30 years old. I had two companies say I need ... A: Doug, You did not say, but I assume that old unit wore out. If you are staying with r-22 and it ...
|
| Furnace Return Make-up Air Questions | 6/2/2009 |
Q: I am installing a 40K btu 92% nat gas furnace (horizontal mount). I have a concentric vent/supply ... A: Jason, I saw this question in our question pool of unanswered questions. You don't want that vent ...
|
| central a/c maintenance cleaning | 5/20/2009 |
Q: After 10 years use, I decided to have my central a/c evaluated for maintenance. I contacted a major ... A: Chris, If the outdoor A/C runs fine after the contactor was changed ( the points burn and that is ...
|
| R 410 pounds required to fill a empty system | 5/19/2009 |
Q: While installing a new roof, the pressure line was hit with a nail. All the R 410 was lost on the 4 ... A: That depends on the size of the unit and length of line set. But, more important is that r-410a oil ...
|
| Window unit | 5/19/2009 |
Q: Mike, I live in 2000 sq ft home in Houston,TX. Our central air conditioning system has never been ... A: You can put plexiglass above it to cover the hole. If you do not have a thermostatic controlled ...
|
| Noisy compressor | 5/16/2009 |
Q: My A/C compressor (carrier,split unit) has a clatter noise out of the cylinder heads about every 10 ... A: Sorry thought I had answered this one. There is not an unloader. Are you saying the pressures ...
|
| air conditioning | 5/16/2009 |
Q: I have a bryant 80 plus natural gas furnace. Have changed out the factory thermostat with a ... A: There should also be a terminal on the tstat marked Rc which you have to jumper from R. If not ...
|
| A/C | 5/15/2009 |
Q: This particular system is a split--heat pump R-22.This unit has a sight glass on the liquid ... A: I am taking this question from our question pool....The sight glass is supposed to be free of ...
|
| TXV valve install/freeze up | 5/14/2009 |
Q: Will a faulty TXV valve make the coil freeze up even if the unit has plenty of refrigerant? My HVAC ... A: It is impossible to tell if the unit is properly charged with a bad txv. The way to trouble shoot a ...
|
| A/C oil in pipe work | 5/14/2009 |
Q: I was installing a new fuse board for the A/C engineer, I made the final connection's but unbeknown ... A: Paul, ask him to explain how having a vacuum on the line set ( a lower atmospheric pressure than the ...
|
| Power Vent water heater | 5/13/2009 |
Q: The vent fan on this heater stays on continuously. The flame comes on and off as needed, but the fan ... A: Dan, you have to have the motor running to make the pressure switch or as you have found out it will ...
|
| AC Compressor Location Dilemma | 5/13/2009 |
Q: Our outside AC compressor unit is located directly outside of our kitchen in the backyard set off ... A: You should never have more than 50 feet of line set. To figure length, you must add 10 feet for ...
|