AllExperts > Heating, Air Conditioning, Fridge, HVAC 
Search      
Heating, Air Conditioning, Fridge, HVAC
Volunteer
Answers to thousands of questions
 Home · More Heating, Air Conditioning, Fridge, HVAC Questions · Question Library  · Free Encyclopedia ·
More Heating, Air Conditioning, Fridge, HVAC Answers
Question Library

Ask a question about Heating, Air Conditioning, Fridge, HVAC
Volunteer
Experts of the Month
Expert Login

Awards

About Us
Tell friends
Link to Us
Disclaimer

 
 
 
About Mike Reavis
(Top Expert on this page)

Expertise
Questions related to "Wet Heat". This is heating your home, office etc. with radiators, panels, and convector apparatus. Steam and water heat. I can answer questions about boilers, piping,and associated parts of these systems. Please do not ask for specific information about how I feel about one boiler, etc. over another--These questions should be directed to a licensed contractor that you know of, or that your neighbors and colleagues look to to provide solutions.

Experience
I have 20 plus years experience, which has lead to passing my state master HVAC license.

Organizations
PHCC, NAOHSM.

Education/Credentials
Completed college

Past/Present Clients
I work on the manufacturer's side of the business currently

   

You are here:  Experts > Home/Garden > Home Appliances > Heating, Air Conditioning, Fridge, HVAC

Questions Answered By Expert  Mike Reavis 
In Category  Heating, Air Conditioning, Fridge, HVAC

SubjectDate Asked

gas furnace hot surface ignition does not glow11/20/2009
  Q: We have a bryant 373LAV horizontal gas furnace. it failed 1st time we turned on this year. when ...
  A: You need to be sure that the pressure switch is closing its normally open contacts before you ...
furnace not firing up11/19/2009
  Q: We bought a house recently that has a old Olsen (HTL-100B) furnace. Today we had the the tank ...
  A: Sorry about the confusion. You really need to get a service relationship with your fuel oil ...
furnace not firing up11/19/2009
  Q: We bought a house recently that has a old Olsen (HTL-100B) furnace. Today we had the the tank ...
  A: It sounds as if you should call the propane company for service to determine if there is a problem ...
Boiler in apartment building11/18/2009
  Q: I just bought a 11 unit apartment building with a hot water boiler. The old owner shut the boiler ...
  A: If the boiler is condensing the flue gasses, because the boiler is cold, or is not piped correctly, ...
heating11/18/2009
  Q: The inducer fan motor is turning on then blower motor kick in then I hear the spark doing his job ...
  A: I would of course check that the gas is on, and the gas control and shut off valves are all turned ...
Rheem RBHC Air Handler11/15/2009
  Q: I have a newer Rheem RBHC Air Handler installed horizontally in my attic. The installer had to come ...
  A: If the filter is in the air handler, it is at the end opposite, or at least furthest away from where ...
PILOT ASSEmbly11/13/2009
  Q: I need a pilot assembly for a York Heater thats about 30 years old. Where might I be able to find ...
  A: check locally to you in the yellow pages for air conditioning and heating (sub: parts, ...
Heap Pump Fan and Heat Issues11/9/2009
  Q: We have a 10 year old heat pump. It cooled fine this summer, but when we switched it over to heat ...
  A: You should call a service technician to do a diagnostic on the system. It sounds like the"reversing ...
Boiler related question11/7/2009
  Q: I have a question related to troubleshooting my boiler. There is a vertical glass tube with valves ...
  A: What you have described does not sound too unusual. Steam heat systems require a special technician ...
Radiant Baseboard Bangs!11/5/2009
  Q: We have a boiler system that heats our 1 and 1/2 story home. We haven't had any problems with it ...
  A: If you make your hot water for your taps from the boiler that you heat the house with you will have ...
residential heating11/4/2009
  Q: My daughter and son in law recently purchased a smaller raised ranch with full basement built in ...
  A: You can benefit from running the fan--but if the ductwork is installed in an unconditioned space, ...
cold air return capacity11/2/2009
  Q: I have a 2000 s.f. 2 story farmhouse I restored myself. I put in a 2 ft X 2 ft air shaft from the ...
  A: If I understand this correct, and you have essentially a 2'square duct connected to the return side ...
FLOODED WEIL-McCLAIN BOILER10/30/2009
  Q: .I STUPIDLY OPENED THE WATER SUPPLY VALVE ON MY WEIL-McCLAIN OIL FIRED STEAM BOILER AND WALKED AWAY. ...
  A: The biggest problem that you may have caused is that you have stirred up allot of sediment that may ...
Malfunctioning Weil-McLain Boiler10/29/2009
  Q: I have a Weil-McLain HE Series 3 boiler that began malfunctioning about a week and a half ago. ...
  A: I worked on allot of these--the information that I provided is based on what I did to get these ...
commercial baseboards10/28/2009
  Q: I have a commercial building with a boiler. I have a few 50 plus year old rads with a fan. It is ...
  A: Wow, a picture of the equipment would make this allot easier Try Modine for a source, very good ...
radiant heat in bathroom floor10/23/2009
  Q: Remember us? You switched the steam boiler to hot water in our Capitol Hill rowhouse over 5 years ...
  A: I have rfh in our master bath. It was expensive, and allot of work, and I can still feel where the ...
Carrier furnace not heating.10/23/2009
  Q: The furnace is around 10 years old. It was working great and just quit. I power cycled and blower ...
  A: If this is a hot surface ignition system it is likely that the ignitor is cracked and needs to be ...
Adding a zone and domestic hot water in boiler replacement10/23/2009
  Q: I have a commercial building being heated by two split systems. The climate controlled sq. footage ...
  A: You may be able to get an air handler now with enough push on the air side to overcome the loss ...
radiant heat in bathroom floor10/23/2009
  Q: Remember us? You switched the steam boiler to hot water in our Capitol Hill rowhouse over 5 years ...
  A: Wow, Small world. I think about your family, and the job when I am in that part of town. Nearly ...
Air Conditioner Compressor Inline Dryer10/22/2009
  Q: I was just told that I have a bad compressor on my downstairs American Standard Condenser. I have a ...
  A: You should get a copy of the original manufacturer installation directions and read them--then have ...
trane outdoor pump10/19/2009
  Q: Live in West Virginia. Outdoor Trane pump "freezes up" stops running when the heat is on and the ...
  A: What you are describing CAN be normal winter operation of a heat pump. Usually, after one operates ...
using pex for old hot water radiators10/19/2009
  Q: i recently aquired a large 3 story brick house in pittsburgh pa that is divided into 3 apartments, 1 ...
  A: Old radiators, and convectors are held together with "push-nipples". If your radiator is held ...
anti freeze10/18/2009
  Q: what type of ante freeze do you use in a wet system and how do you put it in?
  A: The boiler manufacturer may have recommendations about this. I am pretty sure that propylene glycol ...
steam heat leak10/17/2009
  Q: In our community center we have several leaks in the piping of our steam heat system. Is there some ...
  A: No, sorry. When I remind you of your experiments with distillation in school, you will remember ...
Baseboard Radiator System Maintenance10/16/2009
  Q: Last year we moved into an older home with a Weil-McLain, Boiler Model# CGM-4, natural gas, ...
  A: You now have an "air-out" system. Due to the need to maintain air above the water in the old tank ...
using pex for old hot water radiators10/16/2009
  Q: i recently aquired a large 3 story brick house in pittsburgh pa that is divided into 3 apartments, 1 ...
  A: Get a few quotes to do the work that you are describing. Get someone to help you crunch the numbers ...
boiler buzzing10/16/2009
  Q: I just got a new boiler heating system put in, the old one was broken. I think it is a combi (if ...
  A: The only thing I have ever heard that may be similar to your noise is when these boilers fire, then ...
using pex for old hot water radiators10/16/2009
  Q: i recently aquired a large 3 story brick house in pittsburgh pa that is divided into 3 apartments, 1 ...
  A: Please realize that the gas company will charge for each service usually on a monthly basis. (three ...
Baseboard Radiator System Maintenance10/15/2009
  Q: Last year we moved into an older home with a Weil-McLain, Boiler Model# CGM-4, natural gas, ...
  A: You should contact Weil-Mclain, and get the piping diagram to this boiler, or the cg boiler. If you ...
Radiator Question10/14/2009
  Q: I have been searching and searching but haven't come across anything specific to my situation. I ...
  A: What you are describing sounds like a steam system problem; however, the only time I have seen the ...
Payne electric heat pump system10/12/2009
  Q: I am wondering why I am blowing a 5 amp fuse consistently. I have checked the 24 volt wires for any ...
  A: Somehow you have a direct short. You should turn off the high voltage to the air handler, and using ...
Heil Dc 90 Furnace.10/12/2009
  Q: I have a Heil Dc 90 Model # NUGM074EGb1 Propane Furnace that when the thermostat is turned up the ...
  A: I would be sure that I have adequate gas pressure across the gas valve, before I installed a new ...
my furnace will not kick on10/10/2009
  Q: i got a 1978 heil model HUGC105CG01 and it wont kick on after i turn up the themastat till it ...
  A: You should temporarily install a jumper wire across the R and W terminal of the furnace at the ...
Regarding Package Ac10/10/2009
  Q: Hey Mike what's up man i need a favor to ask you because iam a student in HVAC field.My simple ...
  A: A package unit is used in small residences, and light commercial applications. They are available ...
Steam Radiator Reflector10/9/2009
  Q: I have a small (20" x 20") steam radiator in my bathroom. It is set about 1/2 of the way into the ...
  A: I would think that you could use cardboard sheets wrapped with aluminum foil on the cheap--Have a ...
Boiler burner problem10/8/2009
  Q: I had a local Plumbing and Heating contractor service my home heating oil fired boiler. It is a ...
  A: Please find a local contractor who will use test equipment to set up your burner. It has been years ...
Humidifiers10/7/2009
  Q: i have a few questions regarding my furnace and installing a humidifier on it. What kind of ...
  A: One of the things that should be done is to find out where all that humidity is going. Unless you ...
baseboard heat10/7/2009
  Q: I bought a new house with an oil fired boiler.On the second floor the pipe comes up through a small ...
  A: Codes are a regional thing, this you would have to check--If you mean practice, then yes it is ...
rheem furnace circuit board10/6/2009
  Q: guess first off better make sure thats what i need. my basement flooded. by the i realized to throw ...
  A: Call your insurance company. Every manufacturer that I know of somewhere in their literature ...
Heil forced air furnace pressure switch10/6/2009
  Q: My gas forced air furnace will not start due to not enough vacuum coming from the draft inducer to ...
  A: You need to get a copy of the set-up and diagnostic service directions from the furnace, and a ...
burnham boiler operates with no call for heat10/5/2009
  Q: I have a new burnham alpine 105 modulating boiler, it heats up supply water to 170F constantly even ...
  A: It sounds as if there is a problem with the set up of the warm weather shut down, or the domestic ...
Heat Pump Dehumidification10/4/2009
  Q: The following is a summary of questions remaining after 2 "best of phoenix" ac companies, with clean ...
  A: Your company may be following a service procedure from the manufacturer. While you ask many good ...
heil heat pump10/4/2009
  Q: I have a older model Green body heil heat pump but cannot tell the model number. It is oblong ,with ...
  A: The best way to determine what size unit should be in your home, you should have a heat load ...
Vents10/3/2009
  Q: Building an 800 square foot rec room, how many cold air returns,cooling and heating vents do I need?
  A: You always need to perform a heat loss/gain calculation on new construction. I am assuming that you ...
new boiler10/3/2009
  Q: my boiler just went that heats my home and hot water, it is being replaced with a columbia csfn 4100 ...
  A: The prices that you mention do not seem to be out of line. It sounds as if they are changing ...
float switches10/2/2009
  Q: How do you hook up a float switch to you air handler?
  A: Float switches are normally installed when the system is new. They are attached to the side of a ...
electric heater10/1/2009
  Q: I turned my heater on this morning and I heard it cut on but the blower didn't kick on. My blower ...
  A: I am assuming that this is an electric furnace without a heat pump unit. It is possible that there ...
Nordyne G5RA Blower9/30/2009
  Q: I have a Nordyne G5RA Furnace. with no AC. I want to run the blower to circulate the hot air from my ...
  A: Oh yeah, r to g will give you the cooling fan speed. If you have a 3 or more speed blower motor, ...
Home Boiler Questions9/29/2009
  Q: I have a 3 year old, Lennox GWB9-IH, High-efficiency, gas-fired, hot water heat boiler. Bassebord ...
  A: OK--Two problems here--I have never lived much above sea level, and the other is that Lennox does ...
Nordyne G5RA Blower9/27/2009
  Q: I have a Nordyne G5RA Furnace. with no AC. I want to run the blower to circulate the hot air from my ...
  A: you should be able to run a pilot duty switch from the r to the g terminal to turn the fan on at ...
central heat/ air conditioner9/27/2009
  Q: Greetings! I have a 3000 sq. ft. home and it is time to replace the heat/ air unit. I want the ...
  A: Top three brands are probably Carrier/Bryant, Trane and Lennox. I sold and installed allot of ...
hot water kick heater9/26/2009
  Q: I am thinking of installing a kick heater in one of the cabinets in my kitchen since it gets a ...
  A: You will probably be successful installing the heater with the diverter tees if you do not have any ...
oil fired water heater vs. indirect water heater9/25/2009
  Q: I'm in the market for a new oil fired boiler with an oil fired water heater or indirect water ...
  A: Any indirect tank hooked up to a boiler will give you a never-ending supply of hot water due to the ...
oil fired water heater vs. indirect water heater9/24/2009
  Q: I'm in the market for a new oil fired boiler with an oil fired water heater or indirect water ...
  A: It is my opinion that the indirect heater is the best way to go. Simply this, the boiler will tend ...
how big a furnace do we need9/21/2009
  Q: We would like to know how many BTU's , or what "size" forced hot air furnace we need to heat a 2,00 ...
  A: Contractors rightly charge for the time involved in doing a heat loss calculation. It should be ...
Replacing Coils9/14/2009
  Q: Mike, I bought my home in 2005 and I have no knowledge of central units. Please help. I have a ...
  A: If your furnace has not been taken care of well, you should get a new furnace. (If the blower ...
ansi code- or local code9/12/2009
  Q: My house is in Katy, Texas it was build in 2000, and the question is does the furnace needs a ...
  A: I am not clear what you are asking. What blower assembly are you referring to? The model number ...
a/c thermostat9/6/2009
  Q: today i was weed whcking and I hit the wire from the ac unit to the house ...it stopped running ...
  A: This is a low voltage cable that is unprotected and vulnerable to repeat damage. It is possible ...