AllExperts > Heating, Air Conditioning, Fridge, HVAC 
Search      
Heating, Air Conditioning, Fridge, HVAC
Volunteer
Answers to thousands of questions
 Home · More Heating, Air Conditioning, Fridge, HVAC Questions · Question Library  · Free Encyclopedia ·
More Heating, Air Conditioning, Fridge, HVAC Answers
Question Library

Ask a question about Heating, Air Conditioning, Fridge, HVAC
Volunteer
Experts of the Month
Expert Login

Awards

About Us
Tell friends
Link to Us
Disclaimer

 
 
 
About john t. borgman
(Top Expert on this page)

Expertise
I work days, so I can only answer early in the day or later in the evening, I live in Oregon. I have been so good at all the other area's of hvac, I am probably the only hvac guy that does not know oil. ( lol ) I am very well versed in gas, electric and heat pumps and will only answer residential applications. I have been known the past decade or so, by my employers as the guy you send when no one can figure it out. Trouble shooting is my special. I understand the physics behind air flow, refrigerants and electricity. I understand programmable t-stats, zone controls, economizers, fossil fuel kits and the engineering thought process in the wiring and construction of residential equipment

Experience
I was lucky enough to start in this field over 25 years ago as an installer, for a company that installed the best duct systems I have ever seen, even to this day. The best ,as far as understanding the way air really flows through a duct system, from the return air to the very last supply register . They also had great pride and the duct work was put in, not only to last 50 years, but to look exceptional. Then as I started doing service work, I was again fortunate that I found a 3 year engineering class being put on be a man that was the educational director for the Entire united states for a society called " the Refrigeration Service Engineering Society " And for the next 3 years I schooled at night and practiced what I learned during the day, a great advantage over schooling and then trying to remember it years later.. Versed in duct design manual J heat gain/loss calculations. Also experience in wine rooms and indoor swimming pool hvac & humidity controls

Publications
I have 2 inventions that have gone through the process and been recorded at the National Institute of Standards and Technology from start to finish and thus been invited to national innovation workshops by the dept. of Commerce and the dept. of Energy. They are waste heat recovery devices that N.I.S.T approved as valid and am currently looking for marketing partners to get this product into the hands of consumers and make a BIG difference in Energy savings for every Household and Eatery and take a big bite in the the peak hours power consumption that face our Utilities companies.

Education/Credentials
factory training in Lennox ,Rheem, Ruud ,Trane, Tempstar ,Carrier, Day&Night, Payne, Bryant, Coleman, Intertherm, Ultra boilers, Unico, Mitsubishi,Sanyo, Taylor, Nicewonger, . Associates degree in Refrigeration Engineering. Certified with Energy Department, Check-me Program, have N.A.T.E. certifications in gas, a/c & heat pump. Teach and apprentice at every company I work at.

   

You are here:  Experts > Home/Garden > Home Appliances > Heating, Air Conditioning, Fridge, HVAC

SubjectDate AskedExpert

GE Fridge GBS22HCPAWW - No defrost6/30/2009Eric Campion
  Q: I have exact same problem as someone who asked the question on 5/8/2007. I have to defrost using ...
  A: You have an electronic control board as opposed to a mechanical defrost timer on that unit. SOund ...
Air handling unit6/30/2009Jim Barnhart
  Q: Sir, I have a trane air handling unit in my basement. I came home from a weekend away on Sunday ...
  A: David, Your description of your unit is a bit un-clear? I don't now how it's installed? Most all air ...
dirty blower fan6/30/2009Craig HVAC Expert
  Q: i have been told that a dirty blower fan can cause you too lose cfms, i plan on cleaning it this ...
  A: Well, the building code for my state does not require it to be hung, joists count as support, it ...
Sealing return air vent6/30/2009john t. borgman
  Q: A neighbor suggested the following tip passed on from an HVAC technician to improve cooling on the ...
  A: Raf, Tell your neighbor not to do that, unless somehow( and I would bet not ) they over sized the ...
a/c condenser not responding6/30/2009Craig HVAC Expert
  Q: my condenser is not responding when i turn on the a/c from the thermostat. i know the thermostat ...
  A: Someone is going to have to get into the control section of the cond unit and check for both control ...
New AC Unit tripping breaker6/30/2009Howard Livingston
  Q: We have a 14 seer Goodman unit that is 13 months old. On Saturday we noticed there was no cold air ...
  A: I would start off replacing the circuit breaker. They can fail like everything else. Did the tech ...
New Outside Fan Motor6/30/2009Bill Brainard
  Q: I am in Houston Texas. I have a 15 year old GE A/AC. Recently the fan outside started making a high ...
  A: The way to avoid this problem is to buy an electrical exact replacement. That is not what you did. I ...
outside condensar freezes on me6/30/2009Jim Barnhart
  Q: it vibrates, misses my condensate pan and leaks on the basement floor. How do I seal the metal ...
  A: Michael, Again, I have no idea what your doing or what type of system you have? The things your ...
TXV Valve install6/29/2009john t. borgman
  Q: I have a 3 yr old Trane unit that has been diagnosed with a bad TXV valve. The part cost is covered ...
  A: Bill, Standard practice is to pump the refrigerant to the other coil , lock it down and re use it. ...
central air conditioning6/29/2009Craig HVAC Expert
  Q: I have a 15 year old CA unit, where the model number is not readable anymore. I have no idea how ...
  A: There are other clues. Sometimes the coil will have a tag, the txv if is has one, and the ...
airconditioner6/29/2009Norval Trimborn
  Q: I live in Houston Texas the tempature is around 100 degrees outside if i have the ac set on 70 at ...
  A: It depends on sizing practices in your area. If your area has high humidity during most of the ...
York AirConditioner6/29/2009Tim McAuley
  Q: I have a 2 yr 3 month old York air conditioner (new home). A little better than 3 weeks ago we had ...
  A: Sherry - If the power surge gets to your unit, it can cause the compressor overload to trip (open) ...
a/c question6/29/2009Norval Trimborn
  Q: i have no low voltage to yellow wire coming from the thermostat or if i test at thermosta only red ...
  A: The majority of thermostats do not have a 24v common wire to them. What are you testing the R(red) ...
a/c question6/29/2009john t. borgman
  Q: I have no low voltage to my outside unit.tried the volt test at thermostat from common to red wire ...
  A: Doug, Next to your furnace is there a condsensate pump, it has the pvc from the coil dumping in ...
Central Air running all the time.6/29/2009Eric Campion
  Q: My central air comes on mid afternoon 2-3 PM and run constant until 7-8 PM without shutting off. I ...
  A: Unfortunately our expertise is with Major Home Appliances only. This would include washers, dryers, ...
Iced Pipe on Trane Unit6/29/2009Howard Livingston
  Q: We have a Trane XL19i Super High Efficiency heat pump that was installed in 2004 that doesn't seem ...
  A: Hate to say it but these evaporator coils they make nowdays can start leaking in a couple of ...
What kind of info/testing should be done to determine replacement AC?6/29/2009john t. borgman
  Q: I live in Kansas, where it's hot and humid in the summer, dry and cold in the winter. My home is ...
  A: James, Take advantage of the contractors coming to your home, who can see what you have in the way ...
Trane XB 1000 air conditioner6/29/2009Craig HVAC Expert
  Q: We just purchased the house with this unit already installed. I turned it on for the first time and ...
  A: The click is likely the contactor, which gets power to work from the air handler. If the outside ...
Replacing outside unit of split system6/29/2009Norval Trimborn
  Q: My system is almost 20 years old. The compressor of outside unit must be replaced. Should the ...
  A: Yes the outside unit only can be replaced, but it doesn't make much sense as a 20 yr. old evaporator ...
Trane XL1800 condensing unit6/29/2009Tim McAuley
  Q: Trying to make this unit work with a Rheem AHU conventional unit. I know the XL is 2 stage and theh ...
  A: Daniel - Whenever you mismatch units your asking for trouble. Most likely you will not get the full ...
airconditiong6/29/2009James
  Q: I have kenmore window a/c which was working last year but just not that I installed and pluged in, ...
  A: Is this a 220vac unit? If so check voltages on wall outlet and breaker in house panel. It may have ...
AC not working properly6/29/2009Craig HVAC Expert
  Q: In the past couple days my AC is not cooling my house I looked at the inside unit and it is freezing ...
  A: The two common reasons for a unit to freeze up is low on refrigerant and poor air flow. The air ...
SWAMPED PACKAGE UNIT6/29/2009Howard Livingston
  Q: I probably have a wild question, but I'm looking at 2 International Comfort Package units: ...
  A: Look at the serial number for a year date in it. Like 184702432. See the 02 ?? I'd think if they are ...
SWAMPED PACKAGE UNIT6/29/2009Tim McAuley
  Q: I probably have a wild question, but I'm looking at 2 International Comfort Package units: ...
  A: Marcos - one of these units is a 5 ton, the other a 7.5 ton. They are both gas pacs and therefore ...
SWAMPED PACKAGE UNIT6/29/2009Jim Barnhart
  Q: I probably have a wild question, but I'm looking at 2 International Comfort Package units: ...
  A: Marcos, If the units have been under water You most likely would need to replace any and all ...
Drip Pan on furnace6/29/2009john t. borgman
  Q: Where is it located? Can mold be found in it? We have a new Trane AC unit and a Trane 2 stage ...
  A: Fred, John borgman here, got this question out of the question pool, I think in my hurry I ...
International Comfort Package units SWAMPED!6/29/2009Craig HVAC Expert
  Q: I probably have a wild question, but I'm looking at 2 International Comfort Package units: ...
  A: My concern would be the fast water causes things to rust and corroded. The other issue is how much ...
A/C add-on6/29/2009Jim Barnhart
  Q: I just received a central air unit but my furnace, a Keep-Rite DC90 ultra high eff. downflow, does ...
  A: Bill, If you want to add AC to the heating system you need an inside cooling coil, an outside ...
AC fan needs hand-starting, then unit stops after 15 mins6/29/2009Bill Brainard
  Q: On the hottest weekend of the year (of course) our home's central AC unit decided to go on the ...
  A: I haven't got the fogest what unit you have. but In general, the outside fan motors do not have a ...
Frost-free freezer has frozen water droplets and making loud buzzing noise6/29/2009Eric Campion
  Q: I'm leasing a home that has a GE Profile Arctica fridge/top freezer (and the home is a friend's so I ...
  A: The model number you have submitted to us is incomplete or not correct for your unit. In order for ...
Gas stove6/29/2009Eric Campion
  Q: I have a Frigidaire Gas Stove Model FGFL79GSA, I keep hearing a sound ever 2 mins sounds like the ...
  A: One of your front burner switches is shorted. Check by disconnecting one at a time till the ...
Need a new A/C & Heater6/28/2009Norval Trimborn
  Q: It is time to get a new system. We have gas. There are various businesses out there who can give us ...
  A: Most major manufacturers equipment are all comparable. In order to compare apples to apples, "good', ...
heil furnace leak6/28/2009Jim Barnhart
  Q: I have just noticed that their is a small amount of water leaking where the copper pipes enter the ...
  A: Tom There are different types of cooling coils, I'm not sure exactly what you have, there was no ...
Outside unit6/28/2009Eric Campion
  Q: We live in the Memphis area, it has been very hot and humid here. I have noticed moisture under our ...
  A: Unfortunately our expertise is with Major Home Appliances only. This would include washers, dryers, ...
venting attics6/28/2009Tim McAuley
  Q: Is there a product that can be used to vent an attic that is temperature controlled and is either ...
  A: Doug - Attic fans are sold in all home improvement stores. Most of these fans are thermostatically ...
is this system overcharged6/28/2009john t. borgman
  Q: the outdoor ambient temp is 90 the indoor ambient temp is 74 the suction psi is 61 the line temp at ...
  A: Then everything is as it should be. Your in a high humidity area and the tstat should be set at the ...
Geothermal HVAC systems and problems6/28/2009john t. borgman
  Q: I am considering replacing my nineteen year old HVAC system with a geothermal system. Would you ...
  A: Bob, John Borgman here, got this out of our question pool. Lets start with if you cannot find ...
is this system overcharged6/28/2009john t. borgman
  Q: the outdoor ambient temp is 90 the indoor ambient temp is 74 the suction psi is 61 the line temp at ...
  A: Terry, First when asking this question the proper terminology is suction line temp and liquid line ...
AC variations6/28/2009john t. borgman
  Q: My wife has a problem with the bedroom temperature in the summer. She is complaining that our AC ...
  A: Alex, The thermostat controlled attic fan will do wonders for the small expense it requires, it ...
AC variations6/28/2009Howard Livingston
  Q: My wife has a problem with the bedroom temperature in the summer. She is complaining that our AC ...
  A: I would suggest a new thermostat, like a Honeywell gold round one from Home Depot or elsewhere. They ...

Page:  Previous  |  58 | 59 | 60 | 61 | 62 | 63 | 64 | 65 | 66 | 67  |  Next


Questions by
Active Experts:
Norval Trimbornjohn t. borgmanMarcus - Air Conditioning and Refrigeration Expert
Blake Ballard (A/C - Heat - IAQ Expert)Jim BarnhartJoe
Fred WeldinJ CookBill Brainard
Eric Campionkdgrayson@gmail.comMike Lehner
Craig HVAC ExpertHoward LivingstonFrank A.
Mike Reavis  

Email this page
     
User Agreement | Privacy Policy | Kids' Privacy Policy | Help
Copyright  © 2006 About, Inc. AllExperts, AllExperts.com, and About.com are registered trademarks of About, Inc. All rights reserved.