About Bill Gibbs Expertise Any questions about R.V.'s not including the automotive end, such as engines and drive trains.
Experience I have been repairing R.V.'s for about 17 years, Service Manager for 5 years, Lead Tech for 4 1/2 years at the largest dealer in area, Troubleshooter clinics in Ore. Dometic, Norcold certified
Education/Credentials High School Graduate, R.V. Troubleshooter Clinics, Springfield Ore.
Past/Present Clients Marathon Motor Coach (Warranty Provider in this area)
Expert: Bill Gibbs Date: 3/28/2008 Subject: 1994 Southwind
Question I own a 1994 Southwind and last night we were trying to ignite the water heater, but we are not able to get a spark to ignite. We know that it's getting gas as we were able to light it with a long lighter. Any suggestions?
Answer Janet, Is this an automatic spark water heater? If so are you even getting a spark? If you are then I would say that you need to check the gap and see that it is about 3/8 inch and then make sure that your L.P. pressure is correct. If you are not getting a spark I would say that you need to change the igniter board. Thanks, Bill