I have a home built in 1955 with a copper radiant heat system.  I wanted to remodel the bathrooms and replace the tile currently on the floors.  I'm concerned that the tile removal could damage the radiant heating system.  

Do you have recommendations on precautions I should take in the kind of contractor I use or with the tile removal methods the contractor should use?

Answer
1955 was a good year for copper radiant floors. Many are still going strong, but many more have starting leaking. We consult on many of these systems. The vast majority have copper or steel pipe place at or below the concrete. Many suffer from corrosion inside or out.

Most tile was set in a thin layer of mortar on top of the slab so chiseling the tile off using typical methods should not be problem. If you can feel the heat output of individual tubing runs caution would be in order.  

Radiant Floor Heating

All Answers


Answers by Expert:


Ask Experts

Volunteer


Morgan M. Audetat

Expertise

Radiant panel heating design, including floors and ceilings, European wall panels and snow melting for residential and light commercial buildings..............................................................-Master of Steam and Hot Water,City of Minneapolis....................................................--- Master Plumber, State of Minnesota...........

Experience

30 years..... Charter Board Member - Radiant Panel Association, former manufacturer of condensing boilers, former national distributor of radiant floor products, son and apprentice of mechanical & plumbing contractor. Current owner---www.BadgerRadiantDesigns.com---Minneapolis mechanical/plumbing contractor specializing in hydronic based, integrated HVAC systems. Radiant floor heating/cooling. Snow Melting. Condensing Boilers. Indirect water heaters. System design, consulting and technical training world-wide. Licensed contractor, designer, installer and consultant.

Education/Credentials
B.S. University WI 1981 CONTINUING EDUCATION: Viessmann Condensing boiler and Solar water heating certification 2010, N.D.S.U. Lead Worker RRP certification 2010, Knight condensing boiler certification 2009, Wrightsoft Manual J CAD certification 2009, RPA Designer & Installer Certification 2008, Nate Hydronic/Forced Air Certification 2008, Uponor/Wirsbo advanced design school certification 2007, Buderus Wall-hung certification 2007, Power Limited License (low voltage controls) 40 CE credits 2005, Basic Hydronic Certification IPEX & Northern Alberta Institute of Technology 1998, Charter Board Member - Radiant Panel Association 1994, Residential Off-Electric to Hydronic Conversion Heating School Canadian Hydronics Council 1994, B&G Little Red School House 1993, Rood Utilities (now Auburn Technical Institute) Oil Burner School 1993 ,Tekmar Controls residential and commercial 1993, Division Manager and Advanced Hydronic Seminar Instructor for the first Exclusively Hydronic Radiant Floor Distributor in the USA 1990, Hydronic Radiant Heating Association Workshop participant with Richard c. Bourne, PE spring 1988, Master Plumbing, Hydronic, Solar Course Red Rocks Community College 1987.

Awards and Honors
2009 System Showcase Award - Radiant Panel Association

©2016 About.com. All rights reserved.