Roofing/SBS Torchdown Underlayment


Santi wrote at 2014-05-17 04:40:51
If you are doing a torch down roof , use base sheet underlayment nailed down with metal cap nails minimum @ 16" on center with 3" overlap on horizontal joins and 6" on vertical joins , use 9" mini roll around the perimeter then drip edge or low rise metal depends on the draining system , target all roof flashings  and one layer of granulated torch down  mat.  