Question
I have a 3 unit hardwired system made up of Firex Model G-18 smoke detectors.  Can I replace one of them with a BRK 9120B?  The directions are not clear.  Neither of the two adaptors that came with the BRK fit the Firex harness hanging from the ceiling.  I could just remove the harness at the wirenuts and tie in the BRK but I don't know if everything is compatable.

Can you help?

Answer
The BRK unit is NOT compatible with the Firex smokes.  You'll have to replace ALL of the smoke alarms with units compatible to each other.  The installation instructions will give you a list of compatible model numbers (usually all from the same manufacturer).  You are going to have to change the wiring harnesses if you're going from a Firex smoke to a BRK one.

Security & Fire Protection Systems

All Answers


Answers by Expert:


Ask Experts

Volunteer


Frank Kurz

Expertise

Questions relating to Burglar Alarm and Security Equipment, Fire Alarm and Extinguishment Systems, Access Control, CCTV Systems, Installation, Service, Testing, Verification

Experience

30 years installing, servicing, and testing security, access control, extinguishment, and fire alarm systems

Organizations
Chair of ULC Working Groups for Fire Alarm Testing (CAN/ULC-S536) and Fire Alarm Verification (CAN/ULC-S537), Executive Director of the Fire Protection Technicians Network (www.firetechs.net)

Publications
www.firetechs.net, Better Business Bureau Magazine, Applied Science Technologists and Technicians of British Columbia (www.asttbc.org) SUPPRESS! and Techs Fire Break Newsletters

Education/Credentials
Associate in Science; Emergency Systems (University of British Columbia); Aircraft Maintenance Technology (BCIT)

©2016 About.com. All rights reserved.