AllExperts > Swimming Pool & Spa Construction & Maintenance 
Search      
Swimming Pool & Spa Construction & Maintenance
Volunteer
Answers to thousands of questions
 Home · More Swimming Pool & Spa Construction & Maintenance Questions · Answer Library  · Encyclopedia ·
More Swimming Pool & Spa Construction & Maintenance Answers
Question Library

Ask a question about Swimming Pool & Spa Construction & Maintenance
Volunteer
Experts of the Month
Expert Login

Awards

About Us
Tell friends
Link to Us
Disclaimer

 
 
 
 
About roger
Expertise
Any questions regarding pool,spa pumps and motors. Any pool and spa operations, problems, chemistry and maintenance. Filters, Heaters, Cleaners,Salt Water Systems. Also consider solar power to heat your home, spa and pool using the power of the sun.

Experience
Over 8 years as a field service technician in pools over 40 years as an electronic field service technician in process control and metrology (precision measurement). Having worked in depth with pool and spa leaks and solutions we are the experts. Years of rebuilding motors. Insulation testing and Solar power.

Organizations
ALLExperts spa volunteer ALLExperts pool volunteer

Publications
Perhaps one day pool and spa articles.

Education/Credentials
Electronics technology Pool and Spa certified tech Precision Measurement certified tech

Awards and Honors
AllExperts Volunteers of the Month

Past/Present Clients
Doctors, Dentist, Lawyers and their thieves.

 
   

You are here:  Experts > Home/Garden > Exterior Decorating > Swimming Pool & Spa Construction & Maintenance > Spa inoperative after prime

Swimming Pool & Spa Construction & Maintenance - Spa inoperative after prime


Expert: roger - 6/25/2009

Question
After the spa goes through the prime stage. The spa runs for a short time then shuts down with a topside reading of "dr" and/or "OHH". One of the 2-spd pumps does not run but has power. A new circ. pump, circuit board & heating element have been installed.

Answer
When the pump is done priming the circ pump must start before the heater comes on or you will get a dry or ohh error. I need more info as in spa make and I think you have Balboa Controller but verify for me. Being a new board I am inclined to jumper or switch settings on the board especially if all pumps worked before. So open up the controller and get the board type like M7 or something. I recently put a new board in a Bullfrog spa when pr ended the heater started to boil and the heater pump didn't start like it should have. Both jet pumps worked fine pressing buttons. I disconnected the heater and repeated the prime unplugged the two speed heater pump only to find 110 volts on low speed but 240 at heater turned out to be a low level configuration problem trying to turn on a non existent circ pump. So more info would help. Thanks