AboutRay Niemi Expertise ASE Master Rated. Ask any questions about Volvo models up to 2000. Runnability, starting and charging system, diagnostic codes, brakes, front end, where to get certain parts. Should I buy this Volvo or not? I will try to answer your question and give you the knowlege to make the best decision in your case.
Experience I started working on Volvo's in 1978 at the dealer and attended all the schools and achieved a Master rating. Since 1999 I have worked at independent shops and now own my own shop.
Organizations Alldata on line repair manuals. IATN network of techs.
ASE rating of Master.
Question Would you where I would find the reset for the SRS light on a 1989 Volvo 760 GLE 2.8 V6.
Answer Thomas,
Fuse five is the test terminal for the SRS.
Fault codes are displayed by flashing of warning lamp. Several faults, if present are displayed in succession at 4 seconds intervals.
Requesting Fault Code Display
Turn ignition On, warning lamp will display a steady beam indicating presence of a fault. (Lamp will otherwise be extinguished after approximately 10 seconds). Wait 15 seconds to allow system to complete self-diagnostics.
Ground test terminal for 2-5 seconds. When ground connection is removed, lamp will commence to display fault code(s) before reverting to steady light. Lamp will flash immediately when ground connection is removed, however this is not a fault code just confirmation that a request has been made.
If no fault code is displayed, switch ignition Off and On and repeat test. If this does not function, check connection to combined instrument. Ground leads must be fitted with spade connectors at both ends. Refer to table for fault tracing repair.
Do not turn ignition Off between request and clearance of fault code. When fault has been corrected, warning lamp must be cancelled (fault code cleared) to restore normal operation. Clear fault code as follows:
Repeat code display procedure by grounding test terminal for 2-5 seconds.
Ground test terminal three times within 1.5-5 seconds, for at least 0.25 seconds on each occasion.
Warning lamp will be extinguished for 4 seconds and then relight for 3 seconds to confirm clearance of fault codes(s). Final extinction of lamp indicates restoration of normal function.
If lamp does not go out, repeat display procedure.